ααΆαα·αααα ααα»ααααααα.
α’ααααααα»αααΆααα§αααααα§ααααΆα αααααααααααΆααα½α contactor, αααααΆαααα»αααααΆαααα·αααααααααα αααααΆαααααΆααααααΆααααααααααααααΆααΆααα’ααα ααα»ααααααΆααΆααΆααααα»αααααΆα.
αα
αααααααααΆα αα
ααΆααααΉαααααΆααΈαααΌα
ααααααΆαααααΆα βA1β αα·α βA2β ααΆα
αααΆααααΆαααααααΆ 24V AC.
αα
αααααααΆααα»α αα
ααΆααααΉαααααΆααΈααααααααααααααΆαααααΆα βL1β αα·α βT1β ααΆααααΌαααΆαααΆαααααααααααΆαα 600V.
ααΎααΆααΆααα α»αα’αααααΆαα·αα»αααααααα? ααΎααΆααΆαααααααααααααFormatααααΌα αα½αααααα? ααΎα§ααααααα½αα’αΆα ααΆααααΈα 24V αα·α 600V αααα»αααααααα½αααΆααααααααααΆ?
ααααα·ααααααααΆααααααΆαααα½ααααα»αααααα αα·ααααΆαααααα ααΆααΊααΆααααααααα»αααΌααααα»ααα·αααα·α αααααααΈααααααΆαααααΎα±ααα’αααααααΎααααΆααααααΆαααα ααΎ Reddit ααααΆααααα’αΎα α αΎαααΆααΆαααΎαα‘αΎαααΆαααααααΆαααααα»ααααα½αααα βAha!β αα αααα»αααααααααααααα·ααααα’αααα·αααΈα.
α’αααααΎαααααααααα½αααΎα’αΆααααααΆααααΆααΌαααααΆαααααααααααααααα·ααααα ααΌααααααααΆαααΆα.
αααααΆααα βαα½αααααΆααααααΉαααΆα ααα»αβα ααααααα Contactors αα·αααααΆαα ααααΎαααΆα
αααααΊααΆαααααααααΆαα Contactor αα·ααααααΆ δΈζ Ή α§αααααααα ααΆααΊααΆ ααααααααααΈαααΆα ααααα‘ααααΈααααΆααΆαααααα»α αα·αααΆα ααααα‘ααααΈααααΆααΆαα’αααα·αααΈ ααααα αααα»ααααααααα½αα.
αα αααααα ααΎ Reddit ααΆαα αΆαααααα αΌαααΆαααααααααααΆα α’αααααααΌαααααααα βαα½αααααΆαβ ααΈ βααΆα ααα»αβ αβ
1. βαα½αααααΆαβ (ααααααΈαααααΆ)
- αααααΊααΆααααα 24V AC ααααα’αααα.
- ααααΆααΈαα A1 αα·α A2 α.
- α’αααΈαααααΆααΊα αααΆααααα·α α’αα‘α·α ααααΌαααΆααααα·α ααΆαααααα½αα α ααΆ coil.
αα·αα’αααΈααΏααααααΆ βαααααΉαβ α ααΆαααΆαααααααΆααΊ αα ααα½ααααααΆαα»ααααα·ααΆαααΆαααααΆα (αααα»αααααΈααα 24V AC) α αα ααααααααΆααα½αααΆααααααΆααα coil ααΉααααα ααααΆααα α αΎαααααΆαααΆαααααα αααβα αΎαβααΆβααΆα ααΆαα·αααααΎααΆαααΆααααααααα ααΆααΆ βα α α αααΆαβ αααα’αααα»ααα αααα»αααΆαα·ααΆααα α αΎαα αααααααΆα.
2. βααΆα ααα»αβ (ααααααΈαααα»α)
- αααααΊααΆααααα 600V ααααα’αααα.
- ααααΆααΈαα L1/T1, L2/T2, L3/T3 α.
- α’αααΈαααααΆααΊα αααα»ααααα»αααΆααααααααααααααααα»αααααα·ααΆααααΌαα α ααΆ ααααΆαααααα.
αααααΊααΆ βααΆα ααα»αβ αααααααΎ ααΆαααΆα αα·αααααΆααα ααααΆααααααααΆαααααααααΆααααααΆααααΆαα ααααα ααααααααΆααααα»αααααα αα½αααΆ βαααααβ ααΆαααααα»α α αΎαααααΆαααΆαααααααΆαααααα½αααα αα αααααα βαα½αααααΆαβ (coil 24V) αααα ααααΆααα ααΆαααΆααααΆααααα·α ααααααΆααΆααα»αααΆαααααα±αααα·αααΆαα½αααΉαααΆααααα α·ααα thunk.
αα αααααααα»αααΆααααααΌαααΆααα·α ααΆα’αα»ααααΆαα±αα ααα ααΆαααβααΌα ααΆ 480V α¬ 600Vβα αΌαααααααΆααααΆαα αααΌααααα α¬ααααα α.
ααΆααααααααΆααΌαααααΆααααααΊααΆα’αααΈααααα·αααααα α ααΆ ααΆααααα ααααΆαααααααααα/αααα»α.
αααααΉαααααΆαα ααΆαααΆαααααα 600V αααααΊααΆ αααααααα, αα·ααααααΆααΆαααααααααααααα ααΆαα·αααΆααααααΆ contactor ααααα 600V ααα ααΆααΆααααααΆ βααΆα ααα»αβ (ααααΆαααααα) ααααΌαααΆαααΆααααα‘αΎαααΆαα½αααΉα βααΆα αααβ αα·αα’ααΈααΌα‘αααααααααααΆααααΎααααΈαααααααΆαααααα»ααααα·ααΆα αα αΌαααα 600V α αΌαααααααΆααααΆααααα·ααααΆα α¬αααα.
βα’ααααααααα HVACβα α ααα»α’αααΈααΆαααΆαααααΌααααΆαααααα’ααααα·ααααΆα
ααααα·αααΎα’αααΈαααα βαα½αααααΆααααααΉαααΆα ααα»αβ αα ααααΆαα’αΆααααααααΆααΆαααααααα’ααΌααΈααααα·α αααα»αααΆααΆααΆα’αααααΆααααααααααα·αααααΆααααααα αααα»αααααααααα’αααα ααΆααΊααΆααΈααα»αααααααααααααααΆαααΈααααααΆααααααα’αααα.
α’αααααααΆα HVAC αα αααα»ααααααααα‘αΆα Reddit ααΌα ααααΆααΆαα α ααΆααΆ βα’ααααααααα HVACβ αβ
αα·αα’αααΈααααΎααααααααΆ βαααααΆααβα
- α’ααα (α’αααααααΎααααΆαα)α α’αααααΆαα’αΆααααααααααααα α α’αααααα βCoolβ αα ααΎαααααΌααααΆαααααΆαααααααααααααα’αααα.
- αααααΌααααΆα (βαα½αααααΆααααααβ)α αααααΌααααΆαααααα’αααααΊααΆααααΏαα’αα‘α·α ααααΌαα·α ααααααΆααα ααΆααααΎαααΆαααΎααα»αααΆα 24V AC αααααΆααα»ααααα·ααΆαα ααΆααΆαα½αααααΆα βαααααβ α.
- αααααΆ (24V)α αααααΌααααΆααααααΌααααααΆ 24V ααΌα αααααΆααααααααααααΎααα½ααα α’αααααΆααααΆαααΈααααα αΆααααΆααααα ααααα’αααα.
- Contactor (βα’αααααααααβ)α αα ααΆααααα»αα’αααααΆαααΆααααα αααααΆααααααααααΆααααααααΊααΆ contactor α βαα½αααααΆαβ 24V ααααααΆ (coil) ααα½αααΆααααααΆα.
- α α»α α.
- βααΆα ααα»αβ (240V)α ααΆαααΆααααΆααααα·α αααα coil αα·α βααΆα ααα»αβ (ααααΆαααααα) α ααααααα ααααααΆααααΌα ααααααΈααΆα ααααα‘ααααΆαααααα»α, ααααααα αα βααααβ 240V, 30-amp ααααααααΈααΈαααααα§ααααααααααααααααααα’αααα.
- ααααα»αα ααΆααα 240V ααααααα»αα‘αΎα ααααΎαααΆααααΆαααΈααααα αΆαα αα·ααααα αΆαααααα.
ααΎααααΆα contactor ααΎααα½ααΆ βα’αααααααααβ ααααα α§αααααααααα ααααΆααα 24V ααααααΆααααααα’ααα ααΉαααααΆααΆαααααΌα 240V αααααααΆααα αααααα? ααΆααΉαα α½αααααΆαααααα»αααααα αα·αααααΆαααα·αααααααΆαα.
ααΆααααα ααααΆαααααααααα/αααα»α ααΊααΆαααααΆαα abstraction ααΌααααααααα’αα»ααααΆαα±αααα·ααααΈααΈαααα»ααααα·ααΆαααααααΎα (α§αααααααααα 24V) ααααααααααα·ααα’αΆααΆα‘αΌααααααααααααΆαα αα·αααΆαααΆααα (αααΌααα 240V)α.
ααΌα αααα... ααΎ Contactor ααααΆααααααΆ Relay ααααααα? (ααΆα ααα»ααααα’αααα)
αααααΊααΆαααα½αα‘αΌααΈαααααααΆααα.
βαααα αΎαβ α’ααααααα»ααα·α βαααα»ααααα αΎαα βαα½αααααΆαβ 24V ααααααααα βααΆα ααα»αβ 600V α ααα»αααααααααΆα’αααΈααα αα·αααααΆαα α’αααΈααα αααααΌαα ααααΎα αααααΆ 5V ααΈ Arduino αααααααα»αα’αΆα ααααααααα relay 120V αααααΆααα ααααααα½αα ααΌα αααα contactor ααααΆααααααΆ relay αααα½ααβ
αααααΊααΆααΆααααα ααα‘αααΌαα αααα»ααα αααα»ααα·ααααααα α αΎαααΆαα·αααααΉαααααΌαααα.
ααααααααααα½αααα αααααααααΌα ααααΆ αααααΆααα (ααΆααααα ααααΆαααααααααα/αααα»α), αααααα½ααα ααααααα ααΊαα»αααααΆααααΆααα ααΆααα·ααΆαααΆ contactor ααΊααΆ relay αα ααΊααΌα ααΆααΆααα·ααΆαααΆααααααααΈαα’αΆαα ααααΆααααααΆαααααα sedan αααα½αα αα½αααααΆααααΈαααΆααααΆαααΈα αα·αααα ααα»αααααα½αααααΌαααΆααα ααΆα‘αΎαααΎααααΈ ααΉα ααααα»αααααα α αΎααα½αααααα·ααααααα.
ααΆααα»αααααΆαα βααα αβ α¬ βααΆαααβ ααΊααΆ ααααααααΆ, αα·ααααααΆααΌαα ααα»α«ααααααα.
αααα αα·α ααΆααα»αααααΆααΊ ααΆααααααααΆαα Arc α.
αα αααα’αααααααΌαα’αααΌαααααΎαααΆαααα (ααααα»α resistive) α’αααα·αααΈααααααΆαααα’αΆαα ααα»αααααα αααα’αααααααΆααΆααα·ααααΌααααααα½α (ααααα»α inductive) ααααααΆαααα·ααα αααα»ααααΌαααααααα½αααα α αΎα ααααα»ααα α’αααα ααΆαα·αα αααααααα ααΆααΉαααααΆααΆααααααΆα’αααα·αααΈα±ααα αΌαααααααααΎαααα»αααααα αααα ααααα β ααααααααααααα·αααααΆαααααα α ααΆ ααααΌα’αααα·αααΈ.
- αα½α αααααΌαα ααΊααΆαααααα sedan α ααΆααααΌαααΆααα ααΆα‘αΎααααααΆααααααα»αααΆαααα αα·αααα’αΆαα ααααα·αααΎααΆααααΆααΆαααααΌααααΌααααααα½α ααα arc ααΉααααααΎαα‘αΎααααΆαααααΆααααααααΌα αααααααΆ αααα αααα αααΆα αα·αααααααΆααΆαα½αααααΆααΆααααΆαααΆαααα ααα α ααα αΎαα.
- αα½α α’αααααααΆαααααα ααΊααΆααααααααΈαα’αΆααα ααΆβααΊβααΆ ααααααααααααΆαααΆααααααΎααααΈαααααΆαα arc αααα. α ααΆααααΌαααΆααα ααΆα‘αΎαααΎααααΈαααααΆαααΆαααΈαα·αααΈααΆααααααααααα ααααΆαααααΌααααΌαααα.
αααααΉαααααΆαα Relay αα½α αα»αααΆαα ααααααΈα Contactor αα½α αααααΆαααΆαααΈαα·α ααΆαααααΌα αααΌααΌ. α ααΆααααΎααααααααΆαα½αααΉααααααΆααααααΆααααααααααα αααααΆαααααΆααααααααΆααααααΌααααΌααΆα α αΎαααΆααΉαααΆαα ααααααααα αΌαααααΌα’αααα·αααΈβ ααααααααααα·ααα αα·αα§ααααααααΆαααα·ααααααααΌαααΆααα ααΆα‘αΎαααΎααααΈααΆααααααΉα αααααΆαα αα·ααααααα arc ααααααα»αααααααααα»ααααΆαααΈααΈαα·ααΆααΈα.
αααααΆααΌαα ααα»αααααΎαααΆα ααααααααΆαααααΎααααΆαα (ααΌα ααΆ AC-3 αααααΆαααααΌααα) αααααΆααΆααΆαααααΉα spec αααααααΆααα’ααα ααααααααααΎαα’αααΈ ααα contactor ααααΌαααΆααα ααΆα‘αΎαααΎααααΈααααααα.
α ααα»α’αααΈααΆαααΆ 24V AC? α αΎαα ααα»α’αααΈααΆαααΆαααα»αααΎα 24V DC αα·α 120V Coils?
αααααΆαααΎααααααααα ααΌαααααΎααα·αα α ααα»α’αααΈααΆαααΆ 24V AC coil?
ααα»ααα βαα½αααααΆαβ ααΆα ααααΆαα’αααΈ ααΎααααΈααααΎααΆαα½αααααα»α βααΆα ααα»αβ α α’αααααααΎαααΎαααα»α coil αααααα’ααααΎααααα’ααα ααΆααΆααααααααααααααααααα.
- 24V AC (The βHVAC Specialβ): αααααΊααΆαααααααΆααααααααα βααα’αααααααααΆααβ αααααΆαα HVAC αααα ααααΆα αα·αααΆαα·ααααααα ααΌα ααΆαα αααα»αααΆααα·ααΆααααΆ Reddit αααα α ααα»α’αααΈ? αααααααΆααα αα·αααΉαααΆαα αα ααααααααααααΆα 1950 α’αααΈαααα’αααααααΌαααΆαααΊααΆααααααααΆαααα α§αααααααααα ααΎααααΈααα½αααΆα 24V AC ααΈ 120V AC α ααααΆα rectifiers ααααΆα capacitors ααααα ααΆααααΆααααααααΎαααΆαα.
- 24V DC (The βPLC Standardβ): αααααΊααΆααααα ααααααααααααααα·ααααα§ααααΆα ααααααααΎαα ααΆαα PLC (Programmable Logic Controller) α§αααααα αΆαααααααΆ αα·αα§ααααααααααΆααα»αααααααααααΎαααΆαααΎ 24V DC α ααΆααΊααΆαααααααΆααααααΆααααα½αααααΎααΈααΈαα αααααΆαααααααα·ααααΆααααΏαααΏαα.
- 120V AC / 240V AC (The βOld Schoolβ): α’αααααααΉαααΎα contactors ααΆαα½α coils ααα»αααααααααααα αααααΊααΆαα·ααΈααΆαααααα αΆααααΆααααα’αααααααΆααααααααΎααα»ααααααΆαααααααΆαααΎααααΈααααααααα contactor α ααΆααΆαααα (αα·αα αΆαααΆα αααΆαα§αααααααααααα) ααα»ααααααΆαα·αααΌαααΆααα»ααααα·ααΆααααααΆααα’ααααα αα ααααααααα»αααΆααααααααΆααααα αΆααααααΈαααααΆ 120V βαααα β αααααα.
contactor αα αααα»αααΌαααααα ααΆαα½αααΉα coil 24V AC ααααααΆ ααααΎαααααααΆααααΆααααΆααααΌαααΆαααααα»ααα»ααααααΆααα’αααααΆα HVAC αα·ααααααΆααΌ PLC αααα αααααααΎααααααα.
ααΈ βααΆααααα»αααααΆβ αα βααααΉαβ
βααΆααααα»αααααΆβ αα αααα»ααααα’ααααααΆαααα·ααααααααααααα αα·ααααααΆααΆααααα»αααααΆααΆαααααααα ααΆααΊααΆααΌαααααΆαααααΉαααααΆααααααααααα’αααα·αααΈααααΎαααΆααα’ααα.
ααΆβααΊβααΆ ααΆααααα ααααΆαααααααααα/αααα»α αα αααα»ααααααααΆαα.
ααΆααΊααΆ βαα½αααααΆαβ ααααΆαα βααΆα ααα»αβ ααΌαα’αααΈαααααααΌαααααΎα.
ααΆααΊααΆ βα’αααααααααβ αααα’αα»ααααΆαα±αααααααΆααΌα αα½ααααααΆααα»ααααα·ααΆααααααΆααααα»αααααΆαα₯αααα·αα αα·ααααααααααΆααα.
ααΆααααααΉαααΈααΆααα»αααααΆααα αα·ααααααααΆααααααΆααΆααααα‘αααΆαααααααα ααΆααΊααΆααααααα’ααααααα ααααΆααα·ααααΆααΈααΆαααααΆααααααΌαααααΏααααααΆαα αα ααΆααΆααα·α ααΆααααααΉα αααααααααααα’ααααα ααΆ αα·αααααΆαα.
ααα βAha!β αααααΊααΆα’αααΈααααα·αααααααααΊα’αααΈα ααα»ααααααα βAha!β ααΉααα·ααααααΆαααααΆααααααα’αααα±ααααααΎαααΆααα αα αααααα βααΆα ααα»αβ αα·αααΉαααΆααααααααααΆαααααααΆαααα·α αα ααΆααααα.
If your βBrainβ (your PLC or controller) is giving the orders but your βMuscleβ (your contactors) canβt handle the load, itβs time to upgrade. VIOX contactors are built to survive the real-world abuse of switching heavy inductive loads, day in and day out.
Donβt let a weak link in the chain cost you thousands in downtime. Check out our lineup of VIOX contactorsβthe βMuscleβ your βBrainβ can count on.




