ααΆααα»αααααΆααααΌαα αααα’ααα ααα αΆαααΆααα αααααΉα αααα’αααα½ααααα αΌαααΆααα
αα½α αααα’ααα ααα αΆα α ααα αΆαααΆαααααΈααααααααααααααααα½ααα ααΆααααααααΈαααα»α (Load circuits) ααΆα αααΎαα αααα’αααααα αα½ααααα αΌαααααααΈαααααααΆα αααΎα αααααΆαα αααΎαααΆαααααααααΆααααΌα‘αΆ (PV strings) αα ααΆαααααααα½α α¬α αααΎα αα»αααααααααΌααα ααΆααα’αΆααααΊαααα (Inverter) α¬α§ααααα DC αα αααααααΆααααααα.
αα½αααΆαα·αα’αΆα ααααΎαααα½αααααΆααΆαααα αααα’ααα ααα αΆαααΆαααααααΌαααΆαααααΎαααΎααααααα’ααααΎααΆαα ααα αΆαααααα»α ααΆαααΆαααΆαααααααΈααΆααΆ ααα αααααααααΎα αα·ααααααΌαααΆααααααααα AC α¬ DCα αααα’αααα½ααααα αΌαααΆααα PV ααααΌαααΆαααααΎαααΎααααααα’ααααΎααα»ααααααααααααΆαα α αααααααααααααααΆαα ααΆαααΆαααΆαα αααααααα αααΆα ααΆαααααΆα αα αααα DC ααΆαααΆαααΆαααΆαααΎαα‘αΎαααα»αααααΆαα (Surge protection) αααααααΆααααααα’ααααΆαααΆααααααΆααααααΎααααΆαααααα α’αΆααΆα αα·αααΆααα ααΆα αααα αΌαααααα’αΆααααΊααααα.

ααααα·αααΎα’ααααααα»αααααΎαααΎααααα’ααααΆααααααααΆααα’αΆααΆα α¬α§ααααΆα αααα ααΌαα αΆααααααΎαααΆαα½α αααα’ααα ααα αΆα αα·αααΆαααααΆαααααΎαααΎα. ααααα·αααΎα’ααααααα»αααααΎααΆαααΎααααααααααΌα‘αΆ PV ααΌαααΎααα ααΎ ααααα»ααααααααααα’αααα½ααααα αΌαααΆααααααααΊααααα’αΆαα·ααα (PV Combiner Box) α¬ VIOX Combiner Box αααααααα·αααα.
ααΆααΆααααααααααααΆααααα’ααα ααα αΆαααΆααα (Distribution Box) αα·ααααα’αααα½ααααα αΌαααΆααα (Combiner Box)
| ααΆαα» | αααα’ααα ααα αΆα | αααα’αααααα |
|---|---|---|
| αααααααααααΆαα | α ααα αΆαααΆααααα ααΆααααααααΈαααα»α (Load circuits) α αααΎααααααα | αα½ααααα αΌααααααααααΆαα PV α¬ααααααΈαααααααΆα αααΎααα ααΆαα·ααααααα·α ααΆααα»α |
| ααααααααααΌαα | ααΆαα ααα αΆαααΆααα AC αααα»αα’ααΆα, αααααα ααα αΆαααΆαααα§ααααΆα αααα, αα·αααΆαα ααα αΆαααΆααα DC αα½αα ααα½α | ααααα DC ααααααααααααΌα‘αΆ PV, αα½αααΆαααΆαααΆααα½ααααα αΌα AC αα αααα»αααααααααα’αΆααααΊαααα (Inverter) |
| ααΈααΆααααααααΆ | αααα»αα’ααΆα ααααααα§ααααα ααααααααΆαααΈα ααααααααα»αααααα»ααα ααΆααααα | αααααααααΆααααΌα‘αΆ (PV array) ααααΌααααα ααααΆααααΌα‘αΆααα‘αΎαααΎααΈ ααααααααα αΌαα αααα DC ααααα’αΆααααΊαααα |
| αα·ααα ααααααααΈ | ααΈααααααααααααααααα ααΆααααααα»α | ααΈαααααα αααΎααα ααΆααα’αΆααααΊαααα α¬α§ααααααα αααααααΆαααααα |
| α§αααααααΌαα | MCB, MCCB, RCCB, RCBO, αα»αααΆααααααΆα αα αααα (Isolator), SPD, ααΆαααΆα (Busbar), αααααααΊα (Neutral bar), αααααααΈ (Earth bar) | α ααα»ααααΈααααααααααΆαα (String fuses), DC MCBs, DC isolator, DC SPD, αααααααααααα½ααα·αα·ααα, ααααΆαααααα (Cable glands) |
| αααα αΆααΆααααααΉαααααααα»α | ααααααα»ααααααααα AC, ααααα·αααΆααααααααααααααΈααΆααΆ, ααααα·αααααα α»ααααα (Fault level) | ααααααα»αααΎαααααααΈ PV (Open-circuit voltage), ααααααα»α Voc ααααααααΆαα, α αΆαα·αααααααααΌα’αααα·αααΈ DC, ααααααα»ααααα αΌαααααα’αΆααααΊαααα |
| ααΆααααααααΎααΆαααΆαααΆα | ααΆααααα»αααΎαααααα·α, ααααααΈααααΈ, ααΆαααα ααααΆαα ααααα’αααα·αααΈα α»αααΈ, ααΆαααΆαααΆαααΆαααΎαα‘αΎαααααααα»αααααΆαα (Surge), ααΆαααααΆα αα αααα | α ααααααΎααααα»ααααα (String overcurrent), α αααααααα αααΆα, ααΆαααΆαααΆαααΆαααΎαα‘αΎαααααααα»α DC, ααΆαααααΆα αα αααα |
| ααΆααααααααΎααΌααΆααα§αααααα’αααα·αααΈ (Enclosure) | α ααα½αααααααΈ, ααα ααααααΆααααΆααααααααααΎα, ααααα·αααΆαααΆα IP, ααΆααααα αααααααααα DIN (DIN rail) | ααααα·αααΆαααΆα IP αααααΆααααααΎααααΆαααααα α’αΆααΆα, ααΆααααααΉαααΆααααααΈ UV, αααααΆααααααΆααα αααα DC, ααααα , ααΆαααααΆααααΆααα αααα αΌαααααααααΎα |
| ααα·αααααααααααΆαααΌαα | ααΆαααα‘αΎαααΆααααααααΆα IEC 61439, ααΆααααααΆααααΆααααααααΆα IEC 60364, ααααααααα·ααααα·ααΆααααααΆααααααααααΎααααα»ααααα»α | ααα·ααααααΆαααα‘αΎαααααααααααΌα‘αΆ (PV) ααΆααααααααΆα IEC 60364-7-712, ααΆαα’αα»ααααααΆααα ααΆαααααααα PV ααΆααααααααΆα IEC 62548, ααΆαααααΎαααΎαα§αααααααΆαααΆαααααα (SPD) ααΆααααααααΆα IEC 61643 |
| ααΎα’αΆα αααα½αααααΆααΆααααα¬αα? | ααΆβααααααΆβαα | ααΆβααααααΆβαα |
ααα ααααΈααααααα αααα’ααα ααα αΆαααααΎα (Distribution box) αααααααααααΎ ααααααΈαααα»αααααα»α (Load circuits). αααα’αααα½ααααα αΌαα ααααα’αααα·αααΈααΈαααααααΌα‘αΆ (PV combiner box) αααααααααααΎ ααααα’ααααααααα.
ααΎα’αααΈαα ααΆααΌα’αααα·αααΈ (Distribution Box)?
αααα’ααα ααα αΆαααΆαααα’αααα·αααΈ αααααααΌαααΆαααα α ααΆααααΆααα ααα αΆαααΆααα α¬αααα’αα DB αα αααα»αααΈααααΆαααΆα αααΎα ααΊααΆαααα’αααααααΆααααα½αααΆαααα’αααα·αααΈ αα·αα ααα αΆαααΆαα ααΆααααααααΈα ααααΆα αααΎαα αα αααα»αααΆαααα‘αΎαααααααααααααααα»αααΆαααΆα αααΎα ααΆααΆααααα»αα§αααααααΆαααΆα αα·αα§ααααααα·αααΎααααααΆααααααααΈααΈαα½ααα.
ααααΏααααααΆααααΆααααα»αααααααΆααΆαααΌα ααΆα
- αα»αααΆαααα α¬α§αααααααααΆα αα ααααα’αααα·αααΈα αΌα
- α§ααααααααααααααααΈααααΆαααΌα (MCBs)
- α§αααααααΆααα ααααα’αααα·αααΈααααααααααααα (MCCBs) αα αααα»αααααΆααα ααα αΆαααα
- α§αααααααΆαααΆαα ααααααα ααααΆα (RCCBs α¬ RCBOs)
- ααΎαα‘αΎαααΆαααΆαα§ααααα(SPDs)
- busbars
- αααΆαα’ααααΆααααΉα
- αααΆαααΈ α¬αααΆαααΆαααΆαααΈ (PE)
- ααααΌαααα DIN
- ααααΆααΈααααα ααα ααααα’αααα·αααΈ
- αααααΆααααΉαααααααααΎα (Cable glands) α¬α αααα αΌααααααααααααααΎα (Conduit entries)
αααα’ααα ααα αΆαααααΎαααααΌαααΆαααααΎααααΆαααα αααα»αα
- α’ααΆααααα ααααΆα
- ααΆαα·ααΆαααααΆαα·ααααααα
- αααα ααα
- αα·ααααΆααΆααΆ α¬αααααΆα
- αααααααα HVAC
- αααααααααΆαααΈαααΌαααΉα
- ααααααααα½ααα·αα·ααααααΆαααΈα
- ααΆαα ααα αΆαααΆαααα’αααα·αααΈαααααΆααα§ααααααα ααΆααααα α’ααΆα
αα½ααΆααΈαααααααα’ααα ααα αΆαααΆααααα·αααααααααΆαααααα αΌααααααααα·αααΆααααααααα ααΆααΆααα½ααΆααΈαααα ααααΆααααα ααΆααααααΈααΆααΆαααααΆααα»ααααα·ααΆα ααΆαααΆαααΆα αα·αααΆααααα½ααααα»αααΆαααααΆαα.
αααααΆααααααααΆααααα’α·αα’αααΈΰΉΰΈΰΈ£ΰΈΰΈͺΰΈ£ΰΉΰΈ²ΰΈααΆααααα»α ααΌαααΎα ααααΆααααΆααα ααΆααααααααααΆααααα»ααααααα’ααα ααα αΆαααααΎαα ααΆαααααααα’αααΈ MCB, Busbar, Neutral Bar αα·α SPD.
ααΎαααα’αααααα αΌαααααΆααΆα’αααΈ?
αααα’αααααα αΌαααΆααα (Combiner box) ααΊααΆαααα’ααααααααααΌααααα»αααααααΈαααα αΌαααΆα αααΎααα αααα»αααααααΈαααα αααα½α α¬α αααΎαα αα αααα»αααααααααααΆααααααααΊααααα’αΆαα·ααα (Solar PV) αααααααααααααααΎααΉαααΆαααααα»αααΊ αααα’αααααα αΌαααΆααα DC αααααΆαααααααααα PV, ααααααααΌααααα»ααααααααααΆαα PV (PV string) ααΆα αααΎααααα αΌαααααΆαα»ααααα αΌααα αααα»αααααααααα αΌα DC ααααα’αΆααααΊαααα (Inverter)α.
αα αααα»αααααααααα’αΆααααΊαααααααααααααΆαα (String inverter) ααΌαα αααααααααΆαα PV ααΆα αααΎαααΉαα αΌααα αααα»ααααα’αααααα αΌαααΆααα ααΆααααΆαα§αααααααΆαααΆα αα·αα§αααααααααΆα αααααααΈ αα½α ααΎααααααΌααα ααΆααααααααααα αΌα DC ααααα’αΆααααΊααααα.
αααΆαααΆαα»ααααααΆαααααα’αααααα αΌαααΆααα PV αα½αααΆαα
- α ααα»α αααα αΌααααααααααΆαααα·αααααΆα αα·αα’αα·αααααΆα
- α ααα»ααααΈααααα (string fuses) α¬α§αααααααΆααααααΆα αα αααα DC (DC breakers)
- α§αααααααΆαααΆαααΆαααΎαα‘αΎαααα»αααααΆαααααααΆααα ααααααααΆαα (DC Surge Protective Device)
- α§αααααααααΆα αα αααα DC (DC isolator) α¬αα»αααΆααααααΆα αα αααα (switch disconnector)
- ααΆααααααααΆαα (busbars) ααΌα αα·ααα
- αααΌαα»ααααα½ααα·αα·ααα (monitoring module) ααααα·αααΎα αΆαααΆα α
- ααααΆααΈααααααΆααααΈ (grounding terminal)
- αααααααααααααααΆααααααΎααααΆαααααα α’αΆααΆα (outdoor cable glands)
- αααα’ααααΆαααΆααααααΆαααααα·αααΆαααΆαααα·ααααΆααααααα (enclosure with suitable environmental rating)
αααα’αααα½ααααα αΌαααΆααααααααΊααααα’αΆαα·ααα (PV combiner box) αα·ααααααααΆααααααΆαααα’αααααααΆααααααααααααΆαααααα ααΆααΊααΆααααααα½αααααααααααααΆαααΆαα αααα DC αα·ααα ααΆααααααααααααααααΎααααααααααΌα‘αΆα.
αααααΆααααΆαααααααααααααα’αααΈαααααααΆααααααααΊααααα’αΆαα·ααα ααΌαααΎα ααΎαααα’αααα½ααααα αΌα PV ααΆα’αααΈ? αα·α ααΎαααα’αααα½ααααα αΌαααΆααααααααΊααααα’αΆαα·ααα (Solar Combiner Box) ααΆααα½ααΆααΈα’αααΈαααααα αααα»ααααααααα PV?.
ααΆααα»αααααΆααααΆααααΈ α‘α ααΆαα ααα αΆαααΆααα αααααΉα ααΆααα½ααααα αΌαααααα αααα (String)
ααΆααα»αααααΆαααααααα»αααΊαα·ααα αα·ααααααααααααααααΈα.
αααα’ααα ααα αΆαααΆααα (Distribution box) ααΆααααααΆααααΎαα ααααΈααααααααααααααααααα½α α αΎααααα ααααΆαα ααΆααααααΈαααα»α (Load circuits) α αααΎαα α§ααΆα αααα αααααααααααααααααα½αα’αΆα α ααα αΆααα ααΆααααααααααααααΎαααααααΊ, ααααααα, αααααααα HVAC, ααΌαααΉα αα·αααααΏαα αααααΌα α ααΆααααααααααΈαααααΆαααΆα ααααα‘ααααΈααααΆα.
αααα’αααα½ααααα αΌαααΆααα PV (PV combiner box) ααααΎαααΆααααα»ααα·ααα αααα»αααααΆα ααΆααα½αααααααΈααααα PV α αααΎα α αΎααα½ααααα αΌαααΆαα ααΆαααααααα½α α¬α αααΎαα α§ααΆα αααα αααα PV α ααα½αααααΆαααΈα’αΆα ααααΌαααΆααα½ααααα αΌααα ααΆααΌαα·ααααα DC αααα½α ααΎααααΈαααααααααααα ααΆααα§ααααααααααααααΎα (Inverter)α.
ααΆααα»αααααΆαααααααΆααααααΌαα’αααΈαααααααααΆαα
- ααΆαααααΎαααΎαα§ααααα
- αααααααααααααΎα
- α₯αα·ααΆααααα ααααααΌα ααΆα
- αα·ααΈααΆαααααααααΆα αα αααα
- ααΆαααΆαααΆαααΆαααΎαα‘αΎα
- ααΆααα ααΆαααα’ααααΆαααΆα
- ααΈαα·αα·ααΈαααα½ααα·αα·ααα
ααΆααα»αααααΆααααΆααααΈ α’α ααααααΈαααα»ααααααΉαααααααΈααααα
αααα’ααα ααα αΆαααΆαααααΆαααΆα αα·ααααααααααααααααΈαααα»αα ααααα»αααΆαααααααααΎααααΆααααΆαααα ααΆααααααΆ α ααααα αΌαααΈαααααααααααααααααααααΆααα§αααααααΆαααΆαααααααα ααΆααααααα»αα.
αααα’αααα½ααααα αΌαααΆααααααααΊααααα’αΆαα·ααα (PV combiner box) αααααααααααααααΈαααααα αααααααΌα‘αΆαααααΎαααΆααααα ααααααααΆααααααΊαααααααααΆααα αααααΈααΆα’αΆααααΊαααα (Inverter) αα·αααααα αααααααααααΆαααααααααΌα‘αΆα’αΆα αα ααααΆαααα»α DC αα αααααα ααα»α αααα αΌααααααα’αααα½ααααα αΌαααΆαααα.
αααααΊααΆααΌαα ααα»ααααααα’αααα½ααααα αΌαααΆααααααααΊααααα’αΆαα·ααα (PV combiner boxes) ααΆαααΆαααΆαααα α·ααααα»αααΆαααα·ααααα ααΎα
- ααα»αααααααΈααΎα (Open-circuit voltage) αααααα PV
- ααΆαααΎαα‘αΎαααα»ααα ααΈαα»ααα ααΆαααΆα
- α αΆαα·αααααα αααααααα αααΆααααΆαααααααΈαα½αα
- ααΆαααααΆα αααααΌα’αααα·αααΈα ααααααααΆαα (DC arc interruption)
- ααΆαααααΆα ααααααααΆααααα»ααααααααΆα
- αααΌα (Polarity) αα·αααΆααααααΆαααααα
ααααααααααααααΈαααααααΆααααααααΊααααα’αΆαα·ααα ααΊααΆααΌαα ααα»ααααααα’ααα ααα αΆαααΆααα AC ααααααΆαα·ααα½αααααΌαααΆαααααααααΎααααΆααααΆαααα’αααα½ααααα αΌαααΆααα PV α‘αΎα αα»αααααΆααααΆααααΌαααΆααα ααΆ αα·ααααααααααα·ααααααΆαααααααα·ααΈαααααΆαα·αααα.
ααΆααα»αααααΆααααΆααααΈ α£α ααΆααααααααααα·αααα»α AC/DC αα·αα§αααααααΆαααΆα
αααα’ααα ααα αΆαααααΎαααααΌαααΆαααααΎααααΆααααΆααΌαα αα αααα»ααααααααα AC αααααΈααΆαααα’ααα ααα αΆαααααΎα DC ααααΆααααααΆααααααααααααΌαααααΆαααα α’αΆαα»α ααααααα’αααα·αααΈ (EV) αα·αααααααααααΆααααααααΊααααα’αΆαα·ααααααααα αααα’ααα ααα αΆαααααΎααααα»αα’ααΆαααΆααααααΆαααααααΎααα»α AC, α ααααααααααααΈααΆααΆ, α ααααααααααΆααααααααΈααααΈ (short-circuit), ααΆαααΆαααΆαα ααααααα ααααΆα (residual-current) αα·ααααααααααααα·ααααΆααααααΆααααααααααΎααααα»αααΌαααααΆαα.
αααα’αααα½ααααα αΌαααΆααααααααΊααααα’αΆαα·ααα (PV combiner boxes) ααααΌαααΆαααααΎααααΆααααΆααΌαα αα ααααα DC ααααααααααααΆααααααααΊααααα’αΆαα·αααα ααΆαααΆαααΆαααααα DC ααΆαααΆαααΉααααΉαααΆααα»α αααααΆαααααΌα’αααα·αααΈ DC αα·αααααααααααα½αα―ααα αααα ααααααααΎααΉαααΌααααααααα α§αααααααΆααΆααααΌαααααΆαααααα·αααα»α DC αα·αααααααααααααα α»αααααααΆαααααααα.

| αα»αααΆαααΆαααΆα | αααα’ααα ααα αΆαααααΎα (Distribution box) | αααα’ααβαααα αΌαβααααΆ PV |
|---|---|---|
| ααΆαααΆαααΆαααΆααααα»αααΎαααααα·α/ααααααΈααααΈ | MCB, MCCB, α ααα»ααααΈα | α ααα»ααααΈααααα, DC MCB, α ααα»ααααΈα DC |
| ααΆαααΆαααΆαα ααααααααα | RCCB α¬ RCBO αα αααααααααα αΆαααΆα α | ααΆααααααΆαα·ααααα·ααα αααα»ααααα’αα DC combiner αα; RCD/RCM αα ααααα AC α’αΆαααααααΎααΆααα ααΆααααα’αΆααααΊαααα α¬αααααααα |
| ααΆαααΆαααΆαααΆαααΎαα‘αΎα | AC SPD | DC SPD αααααααΌαααΆαααααΎαααΎααααααΆααααα»α PV |
| ααΆαααΆααα±αααα ααΆα ααααα‘αα | αα»αααΆαααα, α§αααααααααΆα αα αααα, αα»αααΆααααααΆα αα αααα (switch disconnector) | αα»αααΆααααααΆα αα αααα DC α¬αα»αααΆααααααΆα αα αααααααααααΌαααΆαααΆαααααααααααΆαα PV |
| ααΆααααα ααααΆαααααΆαα (Busbar) | αααΆαααααΆαααααααΆααααααα αααΆα (Phase), ααααααΊα (Neutral), αα·αααααααΈ (PE) | ααααΆααΈααααααΆαααααααΆαααααααα·αααααΆα, ααααα’αα·αααααΆα, αα·αααααααΈ (PE/grounding) |
| ααΆααααα½ααα·αα·ααα | ααΆαααΆααααα ααΆααααα½ααα·αα·αααααΆααα αα·αααΆααααα αΆαααααΆαααΆα | ααΆααααα½ααα·αα·αααα αααααααα (String current) ααααΆααααααααααΆαααΆα αα·αααΆααααα αΆα SPD αα αααααααααα αΆαααΆα α |
ααααα·αααΎαααα αΆααΊααΆαααΆαααΆα AC αααααΉα DC ααΌαααΎα αααα’ααα ααα αΆαααΆαααα’αααα·αααΈ AC αααααΉα αααα’ααα ααα αΆαααΆαααα’αααα·αααΈ DC αα·α ααΆαααααααα’αααΈααΆαααΆαααΆαα ααααααααΆαα (DC) αααα»ααααααααα PVα MCBs, Fuses, SPDs αααααΉα RCDs.
ααΆααα»αααααΆααααΆααααΈ α€α αα ααΆααααααααααΆααααα»α
αα ααΆααααααααααΆααααα»ααααααα’ααα ααα αΆαααααΎα
αααα’ααα ααα αΆαααααΎαααααααΆααααΌαααΆααααα ααα»ααα·αααΆαααααααααααααΆαααα αΌα ααΆαα ααα αΆαααΆααααΆαααααΆαα (Busbar) αα·αααααααΈααΆααΆα αα.
αα ααΆααααααααααΌαα α
- ααΆαααααααααααααΆαααα αΌααα ααΆαααα»αααΆαααα α¬α§αααααααΆααααααΆα α (Isolator).
- ααααααααΆααααΆα (Phase conductors) αααααΌαα αααααα ααΆαααααΆαααααΆαα (busbars) α¬αααα»αα ααα αΆαα ααααα.
- MCBs, RCBOs α¬ MCCBs ααΆαααΆαααααααΈαααα»αααααααα ααα αααααα ααΆααααα α.
- ααααα’ααααΆααααΉα (Neutral conductors) ααααΌαααααΆαααα ααΉααααΆαα’ααααΆααααΉα (neutral bar)α.
- ααααααΆαααΆαααΈ (Protective earth conductors) ααααΌαααααΆαααα ααΉααααΆαααΈ (earth bar)α.
- α§αααααααΆαααΆαααααα (SPD) αααααΆαααααΎα ααααΌαααΆαααααΆαααααΆαααααααΆαα αααα αα·αααααααΈ (PE) α’αΆαααααααΎααααααααααααααα.
αα ααΆαααααααααααααααΌαααΆααα ααΆα‘αΎααααααΆααααΆαα ααα αΆαααααααΈααΆααΆααααααααααααααααα αα·αααΆαα αΌαααααΆαααααα»ααααα·ααΆαα.
αα ααΆααααααααααΆααααα»ααααααα’αααα½ααααα αΌαααΆααααααααΊααααα’αΆαα·ααα (PV combiner box)
αααα’αααα½ααααα αΌαααΆααααααααΊααααα’αΆαα·ααα (PV combiner box) ααααΌαααΆααααα αα‘αΎααα»ααα·αααΆααααα αΌααααα PV string αα·αααΆααααα ααα αααα DCα.
αα ααΆααααααααααΌαα α
- ααααααΌα αα·ααααααααα PV string ααααΌααααα αΌαααΆαααααααααΆααααΉααααα (cable glands)α.
- String ααΈαα½ααα’αΆα ααααααΆααα ααα»ααααΈα (fuse) α¬α§αααααααΆααααααΆα αα αααα DC (DC breaker)α.
- ααααααααααααααΌα αα·αααααααααααΌαααΆαααααΆαααααα αΌαααααΆαα ααΎαααΆαααααΆαα (busbars) α¬α ααα»α αααααΆαα (terminals) ααα αααα DCα.
- α§αααααααΆαααΆαααααα DC (DC SPD) ααααΎαααααΆααααΆαααΆαααΆαααΎαα‘αΎαααααααα»αααααΆααα.
- α§αααααααΆααααααΆα αα αααα DC (DC isolator) α’αΆα ααααΎαααααΆααααΆααααααΆα ααααααααααααΆαααααΆαααααα αΌαααααΆα.
- αααααααα ααα ααααααααΌααααααΆαααα ααΆααα αααα αΌα DC ααααα’αΆααααΊαααα (inverter)α.
- α ααα»α αααααΆααααΈ (grounding terminals) ααααΎαααααΆααααααΆαααα½α§ααααα αα·αααααΌααααα SPD αα ααΉαααΈα.
ααΆααα ααΆααααΌαααααααΆααααΌαααα αααα DC, α ααααΆααα»ααααα·ααΆα (creepage and clearance), ααΆααααα ααααααα αα·αααΆααααααΆααααΉαααα·ααΆααΆαααΆααααα α.
αααααΆααααα·ααααααΆααααααΆααααααααααΎαααΆααααααα ααΌαααΎα ααααΆααααΆαααααααααΎααααα’ααα§ααααααααα αΌαααΆαααααααα’αΆαα·ααα.
ααΈααΆααααααααα’ααααΈαα½ααααααΌαααΆαααα‘αΎααα αααα»αααααααααααΆααααααααΊααααα’αΆαα·ααα (Solar PV)
αααα’ααααΆααααΈαα’αΆα αααα αΆααα αααα»αααΆαααα‘αΎαααααααααααΌα‘αΆαααα½α ααα»αααααααα·ααα ααααααααααααααΆαααααααααα.

| ααΈααΆααααααααααααΆααααααααΊααααα’αΆαα·ααα | αααααααααα’αα | αα½ααΆααΈ |
|---|---|---|
| αα αα·ααααααααααΆαααααααααΌα‘αΆ (PV strings) αα ααΎααααΌα α¬αα ααΎααΈ | αααα’ααβαααα αΌαβααααΆ PV | αα½ααααα αΌααααααααααΆαα (Strings) αααααααΆαααΆαααΆαα ααααααααΆαα (DC string protection) αα·αα§αααααααΆαααΆααααααα ααααααααΆαα (DC SPD) |
| αααΆααααααααΌα‘αΆ (PV array) αα·αα’αΆααααΊαααα (Inverter) | αααα’αααα½ααααα αΌαα ααααα’αααα·αααΈααΈαααααααΌα‘αΆ (PV combiner box) α¬αααα’ααααΆαααΆαα ααααααααΆαα (DC protection box) | αααα αααΆααααα αΌαα ααααααααΆαα (DC input) αα·αααΆαααααΆα αα αααααα»ααααα αΌααα ααΆααα’αΆααααΊαααα |
| ααααααααα ααα ααααααααΆαα (AC output) ααααα’αΆααααΊαααα | αααα’ααα ααα αΆαα ααααααααΆαα (AC distribution box) α¬ααααΆαααα½ααααα αΌαα ααααααααΆαα (AC combiner panel) | α ααα αΆαα αααααααα ααααΈα’αΆααααΊαααα α¬αα½ααααα αΌαα ααααααααΆααααΈα’αΆααααΊααααα αααΎαα αΌαααααΆ |
| αααααα ααα αΆαα ααααα’αααα·αααΈααααα’ααΆα | αααα’ααα ααα αΆαα αααα (Distribution box) / ααααΆααα ααα αΆαα αααα (Distribution board) | ααααααααααααααα»α αα·ααααααΆαααα·αααααααΆααααααααΊααααα’αΆαα·ααα (PV) αα αααα»αααααααααα’αααα·αααΈ |
| αααααα ααααααααΆαα (DC) ααααααααααα’αΆαα»α α¬ααααααααααΌαααΆαα (Hybrid) | αααα’ααα ααα αΆα/ααΆαααΆαα ααααααααΆαα (DC) | α ααα αΆα α¬ααΆαααΆαααααααΈα’αΆαα»α/α’αΆααααΊαααα (Inverter) αααααααΎα ααααααααΆαα (DC) |
αααααΊααΆα ααα»α αααααΆααααα αα αααααα’αΆα ααααΎα±ααααΆαααΆαααΆααα ααα‘αα ααααααααααΆααααααααΊααααα’αΆαα·ααααα½αα ααα½αααααΎααααΆαα ααααααα½ααααα αΌαα ααααααααΆαα (AC Combiner Panels) ααΎααααΈαα½ααααα αΌααα·αααααααΈα’αΆααααΊαααα α¬ααΈααααΌα’αΆααααΊααααααΆα αααΎαα ααΆαα»αααααΆααΈ αααα’αααααα αΌαααΆααα DC αααααΆαααααααααα PV αααααααΎααααΆαααα»ααααα αΌααα ααΆααα’αΆααααΊααααα.
ααΎαααα’αααα½ααααα αΌα (Combiner Box) αααααααΆαααααα DC αααα¬?
αα·ααααααα αααα’αααα½ααααα αΌαααΆααααααααΊααααα’αΆαα·ααα (PV combiner boxes) ααΆαα αααΎα αααα’αααααα DC ααααΌαααΆαααα‘αΎααα α ααααααααα PV αα·αα αααα αΌα DC ααααα’αΆααααΊαααα (Inverter)α αααααΆαααΆαααΆααααα ααααααααααΌα‘αΆααααααααααΎααααΆαα αααα’αααα½ααααα αΌααααααα AC ααΎααααΈαα½ααααα αΌααααααα AC ααΈα’αΆααααΊαααααααα (String inverters) α¬ααΈααααΌα’αΆααααΊαααα (Microinverters) α αααΎααααα αΌαααααΆ αα»αααΉααααααΌααα ααΆαααααααα ααα αΆαααΆααα ACα.
ααααα·ααααααΆααααααΆαααα’αααα½ααααα αΌα AC ααΌα ααααΆαα ααΉααααα’ααα ααα αΆαααΆαααααΌαα αααααα αα»αααΆαααααααΆαα ααααΆαααΆααα»αααααΆα
- α αααα’αααααα αΌα AC αα½ααααα αΌαααααααααΈα’αΆααααΊααααααΆα αααΎααα ααΆαααααααααΌαααΆααα AC αα·α ααΆααα»αα.
- αα½α αααα’ααα ααα αΆα α ααα αΆαααΆαααααΈααααααααααααααααα ααΆααααααααΈαααα»α (Load circuits) ααΆα αααΎαα.
- αα½α αααα’αααααα αΌαααΆααα DC αααααΆαααααααααα PV αα½ααααα αΌααααααααααΆααααααα PV ααΆα αααΎααα»ααααα αΌααα ααΆααα’αΆααααΊαααα (Inverter)α.
ααΌα αααα βαααα’αααα½ααααα αΌα AC αααααΉα DCβ ααΊααΆαααααΆαααααααααΆααααααααααα αααα»ααααα»ααααα’αααα½ααααα αΌαααΆααααααααΊααααα’αΆαα·ααα ααα»ααααααΆαα·ααα½ααααα½ααααααΆαααααααΆααααααααααααααα αααααααααα·ααΆαα’αααΈααΆααα»αααααΆααΆααααααΌααααΌααΆααααΆααααα’ααα ααα αΆα (Distribution boxes) αα·ααααα’αααα½ααααα αΌα (Combiner boxes)α.
ααΎαααα’ααα ααα αΆαα’αΆα αααα½ααααα’αααα½ααααα αΌαααΆααααα¬αα?
ααΆααΌαα ααΊαα·αααΆαααα.
αααα’ααα ααα αΆααααααααΆααα·ααα½αααααΌαααΆαααααΎααΆαααα’αααα½ααααα αΌα PV α‘αΎα αα»αααααΆααααΆααααΌαααΆααα ααΆ αα·ααααααααααα·ααααααΆαααααααααα PV DCα.
ααΌαα ααα»αα½αααΆαα
- α§αααααααΆααα ααααα’αααα·αααΈ AC ααααααΆαααα ααααΆαα·αα’αΆα ααΆααααααΆα αα αααα PV DC ααΆαααααα»ααααα·ααΆααααααα
- ααΆααααα αααααα’ααααΆααααΉα/ααααα αααΆα αα·αααααΌαααααΆααΉαααΆααα ααΆαααααααααΆαααα·αααααΆα/α’αα·αααααΆααααα PV α‘αΎαα
- αααααΆαααΆααααα»αα’αΆα αα·ααααααααααααΆααααα»α DC ααααα
- αααα’ααααΆαααΆαα’αΆα αα·αααΆααααααααααααΉαααΆααααααΈ UV αα·αα’αΆααΆαααΆαα»αααααΆααααΈααΆααααα‘αΎααααααααΌα‘αΆ (PV)
- ααααααααααααααΎα (Cable glands) α’αΆα αα·αααααΌαααΆααααααΌαααΆαααααααααααΎα PV
- αα·αααΆαααΆααααα αααααααααα ααα»ααααΈααααααΆαααααααααααΆαα (String fuse) α¬ααΆααααα αα§αααααααΆαααΆαααααα (PV SPD)
- αα·αααΆαααΆααα·α αΆαααΆααΎααα»αααααααΈααΎα (Open-circuit voltage) αααα»αα’αΆααΆαααΆαα»αααααΆαα
αααα’ααααΆαααΆααααααΎαααΎαααΈααΆααααα α’αΆα ααΆαααααααααααααααααΆ ααα»αααααα»αααΆαα’αααα·αααΈααΊαα»αααααΆα.
ααΎαααα’αααα½ααααα αΌααααα (Combiner Box) α’αΆα αααα½ααααα’ααα ααα αΆαααααΎα (Distribution Box) ααΆααααα¬αα?
ααΆααΌαα ααΊαα·αααΆαααα.
αααα’αααα½ααααα αΌααααα PV αα·αααααΌαααΆααα ααΆα‘αΎαααΎααααΈα ααα αΆαααααα»αα’αααα·αααΈαααα»αα’ααΆααααααα ααΆα’αΆα αα·αααΆααα½ααααα αΌαααΌαα
- ααΆααααα αααααααΈααΆααΆ MCB/RCBO
- ααΆααααα ααααΆαααααα’ααααΆααααΉα (Neutral bar)
- ααΆαααΆαααΆα RCD
- α ααα½αααααΌαα ααααααααααΈαααααααααΆαα
- αα ααΆαααααααααααΆαααααΆαα (Busbar) αααααΆααα ααααααααΆαα (AC)
- ααΆαααΆααααααΆααααααΆααααΉαααααΌααααααΆααααααααΈαααα»αααααα»α
- ααα αααααααααααααααΆαααααααΆααααΆααααααΆααααααααααΎααααα»αα’ααΆα
αααα’ααα ααα αΆαα ααααααααΆαα (AC distribution box) αα·ααααα’αααα½ααααα αΌαααΆααααααααΊααααα’αΆαα·ααα (PV combiner box) αααααααΆααααα αΆαααααααααα»ααααααΆα ααΆαα αΆαααα»αα§αααααααΆαα½αααΆαααα’ααααΌαα αααααΆαα ααα»α αααααΆαααα ααΆααααα»α ααΊααΆααα α»αααααααΌαα αααα»αααΆααα ααΆα.
Selection Checklist
ααΌαααααΎαααααΈαααα½ααα·αα·αααααα αα»ααααααααΎαααΎααααα’ααααΆαα½αα.

| αααα½ααααααΆααααΆαααααΎαααΎα | αααα’ααα ααα αΆαααααΎα (Distribution box) | αααα’ααβαααα αΌαβααααΆ PV |
|---|---|---|
| ααΎααΆααΆααααααααααααααα’αααΈ? | ααααααααα’αααα·αααΈ AC αααααΆααα’ααΆα, α§ααααΆα αααα α¬ααααααααα ααα αΆα DC | αααα PV DC, αα·αααααα’αΆααααΊαααα AC α¬αααααααα DC αααααΌαααΆαα (Hybrid) |
| ααΎααΆααααΌαααααΆααααααΉαααα»αααααα·αααΆ? | ααα»ααααα AC α¬ααα»ααααααααα DC | ααα»αα’αα·ααααΆαααααα PV (Voc) αα ααΈαα»ααα ααΆαααΆααααα»α |
| ααΎααΆααααΌααααα»αα ααααα’αααα·αααΈααααα·αααΆ? | α αααααααα»α (Load current) αα·αα αααααααααα (Feeder current) | α αααααααααααααΆαα (String current) αα·αα αααααααα ααααα»α (Combined output current) |
| ααΎααααΌαααΆαααΆαααΆαααΆαααααααααΆαααα? | MCB, MCCB, RCCB, RCBO, SPD | α ααα»ααααΈααααααααααΆαα/α§αααααααΆααα αααα DC, α§αααααααΆαααΆαααααα DC (DC SPD), α§αααααααααΆα αα αααα DC (DC isolator) |
| ααΎααααα·αααα α»α (Fault level) αα½αααΆαααααααΌαα’αα»αααα? | α ααααααααααΆααααααααΈααααΈαααααααΉααα»α (Prospective short-circuit current) αα ααΎααααΆααα ααα αΆαααααΎα | α αααααααα αααΆααααααα PV αα·αααααααααααααα α»αα ααααααααΆαα (DC fault) |
| ααΎααΆααΉαααααΌαααα‘αΎααα ααΈααΆ? | αααα»ααααα/αααα αααα, αααααΆαα, αααΆαααΈα, αααααααααΆααααα’ααΆα | ααααΌα, ααΆαααα‘αΎαααΎααΈ, αααααα’αΆααααΊαααα (Inverter), αααααααααΆααααΌα‘αΆαααα αααα |
| ααΎααααΌαααΆαααααα·αααΆαααΆααααααα’αα (Enclosure rating) ααααα·αααΆ? | ααααα·α IP, ααΆαα αααα, ααΆααααααααα·α , ααα ααααααΆααααΆααααααααααΎα | ααααα·α IP αααααΆαααααα αααα, ααΆαααΆαααΆαααΆααααααΈ UV, ααααα , ααααααααααααααΎα (Cable glands), αααααΆααααααΆααα αααα DC |
| ααΎααααααΆα α¬ααααα’αααΈαααααααααααΌαα’αα»αααα? | αααααααααααα·ααααααααΎααααα»ααααα»α αααα»αααα·αα IEC 61439/IEC 60364 | αααααααααααα·ααα‘αΎαααααααααααΆααααααααΊααααα’αΆαα·ααα (PV) αααα»αααα·αα IEC 60364-7-712/IEC 62548 |
| ααΎα―αααΆαα’αααΈαααααααα αΆαααΆα α? | ααααΌαααΆαααααααααΎα ααΆααΆαααααααΈ αα·αααααΆααααααΆααααα·αααΆααα | αααααΈαααααααααΆαα (String map) ααααΆααααααΆαααααα (Polarity labels) ααααα·αααΆααα DC ααααΆαααΆαα§αααααααΆαααΆαααααα (SPD) αα·αααΆααΆαα ααα»ααααΈα |
ααα α»αααΌαα αααα»αααΆαααααΎαααΎα
ααα α»αααΈ α‘α ααΆαααααΎαααΎααααααα’ααααΎααα ααααα’ααααααα»ααααα
αααα’ααααααααααΆαααα ααααααααααΆαααα·ααααααΆααααααΆααΆαααααααααααααααααααααα·αααααα α§αααααααΆααααα»α ααΆαααααααα (Busbars) α ααα»α αααα αΌαααααααααΎα α ααααΆαα’ααΈααΌα‘αα ααΆααααα ααααααα αα·αααααα·αααΆααααα»αααααααΆαααΆααααααΆααα.
ααα α»αααΈ α’α ααΆαα αΆαααα»αα§αααααααΆαααΆα AC αα·α DC ααΆα’αΆα ααααΎαααα½αααααΆααΆα
α§ααααααααααααΌαααΆαααΆαααααααααααΆααααααααααα ααα αΆαα ααααααααΆαα (AC) αα·αα’αΆα αααααααΆα’αΆα ααααΎααααΆααααΆααααααΆααααααααΈα ααααααααΆαα (DC) ααααααααααααΆααααααααΊααααα’αΆαα·ααα (PV) ααΆαααα ααα»α DC αααΌα αα·αααΆαααΆααααααΆα αααααΌα’αααα·αααΈ ααααΌααααα·αα·αααααΎααα αααα»ααααααΉααα·αααααααα αα αααααα.
ααα α»αααΈ 3α ααΆααα·αα’αΎααΎααΉαααα»αααΎαααααααΈ (Voc) αααααααααα PV αααα»αα’αΆααΆαααΆαα»αααααΆαα
ααα»ααααααα PV ααΉαααΎαα‘αΎααααα»αααααααααα’αΆααΆαααΆαα»αααααΆααα αααα’αααα½ααααα αΌααααα (Combiner box), α ααα»ααααΈα, α§αααααααΆααα αααα DC (DC breaker), αα»αααΆααααααΆα αα αααα DC (DC isolator) αα·αα§αααααααΆαααΆαααααα (SPD) ααααΌαααααααΎαααΎααααααα’ααααΎααα»αααΎαααααααΈα’αα·ααααΆαααααΆααααααααΌα αα·ααααααα’ααααΎααα»αααΆααααααααααααααα PV αααα½ααα»ααααααα.
ααα α»αααΈ 4α ααΆαααααα ααα‘αΎαα§αααααααΆαααΆαααααα (Surge protection)
αααα’ααα ααα αΆαααΆαααα αααΎαααααααΎα§αααααααΆαααΆαααααααααααΆαα AC ααααααααααααα’αααα½ααααα αΌααααα PV ααααΌαααΆαα§αααααααΆαααΆαααααααααααΆαα DC αααααααααααΉαααα»ααααααααααα PV αα·αααΆααααα αααααααααααΈα ααΆαααααΎααααΆααααααααα§αααααααΆαααΆαααααααα»αα’αΆα ααααΎα±ααα§ααααααα·αααΆαααΆαααΆαααΆα α¬ααΌα ααΆααα»αααΆααααααα.
ααα α»αααΈ 5α ααΆαααααΎααααΆαααααα’αααα½ααααα αΌαααααααΆαααα’αααααααααααααααΆ
αααα’αααα½ααααα αΌααααα PV αα½ααααααααααΌααα»αααΆαααΆαααΆα αα·ααα»αααΆααααααΆαααααααααα αααΆααααΆααα ααααα·αααΎααΆααααΆααααααΆααΆααααααΆαααααααααααααΆαα ααα»ααααΈα ααΆαααααΆα αα αααα α§αααααααΆαααΆαααααα ααΆαααΆααααααΆααααααΆ αα·αααΆααα ααΆααααααααΉαααα·ααααΆαααααΉαααααΌα αααααΆαα·αα’αΆα αααααααΆααααα αΆαα»ααααα·ααΆαααΆαα‘αΎαα.
ααα α»αααΈ 6α ααΆαααΎαααααααΆαααΆααααααΆααααααΆαααααΆααααΆαααααΆα
αααα’ααααΆααααΈαααααααααααΌαααΆαααααΆααααααΆαααα αααΆααααΆααα αα αααα»ααααα’ααα ααα αΆαααΆααα (Distribution box) α’ααααα αα αααααααααΌαααΆαααΆααΆααααα αΆαααΈααααααΈααΈαα½ααα α αααααα αααα»ααααα’αααα½ααααα αΌαααΆααααααααΊααααα’αΆαα·ααα (PV combiner box) αα½αααααααΌαααΆαααΆααααααα’ααααααααΆααααα (string identification) αααΌα (polarity) ααΆααααααΆαα’αααΈααα»α DC ααααα·αα ααα»ααααΈα (fuse ratings) αα·ααα·ααα αα ααΆααα’αΆααααΊαααα (inverter)α.
ααΎα’αααααααΌαααΆααα½αααΆ?
ααααΎαααΎα αααα’ααα ααα αΆα αα ααααααα’αααααααΌαααΆαα ααα αΆαααΆαααααΈααααααα½ααα ααΆααααααααΈαααα»α (load circuits) α αααΎααα αααα»αα’ααΆα αααΆαααΈα ααααααααα·ααααα α¬αααααα§ααααααα ααΆααααα α.
ααααΎαααΎα αααα’ααβαααα αΌαβααααΆ PV αα ααααααα’αααααααΌαααΆααα½ααααα αΌααααα PV α αααΎααααα αα·ααααααααΆαααΆαααΆαααααα·ααααα (string-level protection) ααΆαααΆαααΆαααΆαααΎαα‘αΎαααα»α DC (DC surge protection) ααΆαααααΆα αα αααα (isolation) αα·αααΆααααα αααααααααΎαα αααα ααΆααα’αΆααααΊααααα.
ααααΎαααΎαααααΆααααΈααα αααααααααααααααα½ααααα αΌαααΆααααααααΊααααα’αΆαα·ααα (PV) ααααααααααααααα ααΆααα’ααΆα α¬ααααααααα’αααα·αααΈα§ααααΆα ααααα αααα’αααα½ααααα αΌαααΆααα (combiner box) ααααααααααααααααααα DC αα PV ααααααααααααα’ααα ααα αΆα (distribution box) αααααααααααααααααα»α AC α¬ααΆααααα αΌαααααΆααααααααα’αΆααααΊααααα.
αααα½ααααα½αααΉαααΆαα
ααΎα’αααΈααΆααΆααα»αααααΆααααΆαααααΆααααα’ααα ααα αΆα (distribution box) αα·ααααα’αααα½ααααα αΌαααΆααα (combiner box)?
αααα’ααα ααα αΆαααααΎααΆαα ααα αΆαααΆαααααΈααααααα½ααα ααΆααααααααΈαααα»αα αααΎαα αααα’αααα½ααααα αΌαααΆαααααααΎααΆααα½ααααα αΌαααααααΈαααααα αααΎα αααααΆααααααΆααΊααΆαααα PV αα ααΆαααααααα½α α¬α αααΎααα»αααααα αααα’αΆααααΊαααα α¬α§ααααααα αααααααΆααααααα.
ααΎαααα’αααα½ααααα αΌαααΆααα PV (PV combiner box) ααΌα ααααΆαα ααΉααααα’ααα ααα αΆα (distribution box) αααα¬αα?
αααα’αααααα αΌαααΆααααααααΊααααα’αΆαα·ααα (PV combiner box) ααααΌαααΆααααααΎαα‘αΎααααααΆαααααααΌααααα»αααααααΌα‘αΆ αα·αααΆαααΆαα ααααα’αααα·αααΈααααΆαα (DC)α αααα’ααα ααα αΆαα’αααα·αααΈ (Distribution box) ααααΌαααΆααααααΎαα‘αΎααααααΆααα ααα αΆαααααααΈααΆααΆ αα·αααΆαααΆαααααα»αα’αααα·αααΈα.
ααΎαααα»αα’αΆα ααααΎαααα’ααα ααα αΆαα’αααα·αααΈααααααΆαααααΆααααααααΌα‘αΆ PV ααΆααααα¬αα?
ααΆααα»αααααΆααααΆαααα‘αΎαααΆααααΌα αα·αα§αααααααΆααααα»αααααΌαααΆαααΆαααααα αα·ααα ααΆα‘αΎααααααΆααααα»α DC ααΆααααααααααα PV, α αααα, ααΆαααΆαααΆαααααααΌα‘αΆ, ααΆαααααΆα αα αααα, ααΆααααα αα§αααααααΆαααΆαααααα (SPD) αα·αααααααααααα·ααααΆαα αααα’ααα ααα αΆαα’αααα·αααΈ AC ααααααΆαα·ααα½αααααΌαααΆααααααααΆα’αΆα ααααΎααααΆααααΆααααααα.
ααΎααΆαα§αααααα’αααΈαααααα ααΆααααα»ααααα’ααα ααα αΆαα’αααα·αααΈ?
α§αααααααΌαα αα½αααΆα MCBs, MCCBs, RCCBs, RCBOs, SPDs, αα»αααΆαααα, ααΆααααααα (busbars), ααΆαααααααΊα (neutral bars), ααΆαααααααΈ (earth bars), α§ααααααααααΆαα (terminals) αα·αααααααααα DIN (DIN rails)α.
ααΎααΆαα§αααααα’αααΈαααααα ααΆααααα»ααααα’αααααα αΌαααΆααααααααΊααααα’αΆαα·ααα (PV combiner box)?
α§αααααααΌαα αα½αααΆαα ααα»ααααΈαααααααΌα‘αΆ α¬α§αααααααΆααα αααα DC, α§αααααααΆαααΆαααααα DC (DC surge protective devices), αα»αααΆααααααΆα αα αααα DC, ααΆααααααααα·αααααΆα αα·αα’αα·αααααΆα, αααΌαα»ααααα½ααα·αα·αααααααααΌα‘αΆ, α§ααααααααααΆααααααααΈ αα·αααααααααααααααΎααααααΆααααααΎααααΆαααααα α’αΆααΆαα.
ααΎααααααααααΌα‘αΆαααααααααααα αΆαααΆα αααααΌαααΆααααα’αααααα αΌαααΆααα (combiner box) αααα¬αα?
ααααααααααΌα ααααααΆααααααααααΆαααααα½α α¬ααΈαα’αΆα αααααΆαααααααααΆαααα ααΆααα’αΆααααΊαααα (Inverter) ααααα·αααΎα’αΆααααΊαααα αα·ααααααααααααα·αααα»αααΌαααααΆαα’αα»ααααΆαα ααααααααααααααααΆααααααααααΆααα αααΎα α αααΎαααααααΎαααα’αααα½ααααα αΌα (Combiner box) ααΎααααΈααΆαααΆα αααα αααααααααΎα αααα½ααα·αα·ααα αα·αααααΆαα.
ααΎαααα’αααα½ααααα αΌα (Combiner box) ααΆαααααα AC α¬ DC?
αααα’αααα½ααααα αΌαααΆααααααααΊααααα’αΆαα·ααα (PV combiner box) ααΆαα αααΎαααΆαααααα DC αααααααΎαα»ααααα αΌααα ααΆααα’αΆααααΊααααα ααααααααααααααααααΎααααααα½ααααα αΌα AC ααΎααααΈαααααΌααα·αααααααΈα’αΆααααΊααααα αααΎα α¬ααΈααααΌα’αΆααααΊααααα ααααα·αααα»α αα·αα§αααααααΆααααα»αααΊαα»αααααΆα.
ααΎαααα’αααα½αααΆαααααααΌαααΆαααΆαααΆαααΆαααΈααΆαααΎαα‘αΎαααα»αααααΆαα (Surge protection)?
ααΆααααΈαααααααα’αΆα ααααΌαααΆαααΆαααΆαααΆαααΈααΆαααΎαα‘αΎαααα»αααααΆαα α’αΆαααααααΎααΆααα ααΆααααααααα αααα’ααα ααα αΆα (Distribution box) α’αΆα ααααΎ AC SPDα αααα’αααα½ααααα αΌα PV ααΆααααααΆααααΌαααΆα DC SPD αααααααΎαααΎαααΆαααα»α PV αα·αααααααααααααΆαααα‘αΎαα.
ααΎα’αααΈααΆαααααΆααααΎαααΎαααααααΆαααααα»ααααααΆαααααα’αααα½ααααα αΌα PV?
αααααΆααααΆααααααΌαααΊααα»αα’αα·ααααΆαααααααααααΆαα PV αα½αααΆααααΆααααααααΌαααα»αααααααΈααΎααααα»αα’αΆααΆαααΆαα»αααααΆααα αααααΆααααααααΌααα·αα·αααααΎαα αααααααααααααΆαα ααΆαααΆαααΆαα αααααααα αααΆα ααααα·α DC SPD ααααα·αα§αααααααΆααααααΆα α DC (DC isolator) ααααα·αααΆαααΆααααααααα’αα (Enclosure rating) αα·αααΆααα ααΆα αααα αΌαααααα’αΆααααΊααααα.
ααΎα’αααΈααΆαααααΆααααΎαααΎαααααααΆαααααα»ααααααΆαααααα’ααα ααα αΆα (Distribution box)?
α αΆααααααΎαααααααααααα»ααααααααα α αααααααα»α α ααα½αααααααΈαααα αα ααααα·αααα α»α α§αααααααΆαααΆα ααα αααααααααΎα ααααα·αααΆαααΆαααααααΌ (Enclosure rating) ααΆααααα αααααα’ααααΆααααΉα/ααΈ αα·ααααααααΆαααα‘αΎααααααΆαααααααα.
αααααα
ααΌα ααα αΆαααΆααα (Distribution boxes) αα·αααΌαααααΌααααα»αααΆααα (Combiner boxes) α’αΆα ααΎααα ααααααααααΆαα ααΆααααα ααα»αααααα½ααΆααΈα’αααα·αααΈααααααΆααΊαα»αααααΆα ααΌα ααα αΆαααΆααααααα ααααΆααααα ααΆααααααΈαααα»ααααααΆαααΆαααΆαααΆαα α ααααααΌαααααΌααααα»αααΆααααααααΊααααα’αΆαα·ααα (PV combiner box) αααααΌααααα»αααααααΈαααααααΆαααααααα’αΆαα·αααααΆα αααΎα αα·ααααααααΆαααΆαααΆααα αααααα ααααααααΆαα (DC) αα»ααααα αΌααα ααΆααα§ααααααααααααααΆααα (Inverter)α.
ααΎααααΈααααΎαααΎαααααα»ααααα·ααΆα αα»αααααΎαααΎααααααα’ααααΎααΌαααΆαααΆααααα ααααααΌαααα½ααα»αα ααΌααα·αα·αααααΎααα»αααΆαααΆαα»α αααααΆαααααα·αα·αααααΎαααα»α α αααα α§αααααααΆαααΆα ααΆαααααα·α αα AC/DC ααΈααΆααααα‘αΎα ααααα·αααα·ααααΆα ααΆααααα αααααααααΎα αα·ααααααΌαααΆαααααΆαα.
αααααΆααααΆαααααΎαααΎαααα·ααα VIOX ααΌααα·αα·αααααΎα αααα’ααα ααα αΆα αα·α αααα’αααααα αααααααα·ααα αααααΆααααααααΎααΆαααααΆααααα’α·αααααΈααΈ ααΆαααααΎαααΎαααΌα ααα αΆαααΆααα, αααΆαααΆαα» αα·αααΆααααααΆααααααααααΎαααααΌαααααΌααααα»αααΆααααααααΊααααα’αΆαα·ααα (PV combiner box), αα·α ααΆαααΆαααΆα PV DC.
Sources Used
- αα·αααααΆαααΌαα ααααααΆααα ααα αΆαααΆααα (Distribution board)
- αα·αααααΆαααΌαα αα IEC 60364 αα·αααα·αααααααααααΆααααααααΊααααα’αΆαα·ααα (PV)
- αα·αααααΆαααΌαα αα IEC 61439
- ααα·ααααα§ααααααααααα ααααα’αααα·αααΈ (Inverter) αα·αααααααααααΆααααααααΊααααα’αΆαα·ααα (PV)