VIOX VM6RT / RT-A / RT-P Series Thermomagnetic Double-Adjustable MCCB covers 8 frames from 125 A to 2000 A (3P/4P, AC 400 V, Ui 1000 V, Uimp 8 kV) with field-adjustable thermal overload (0.8–1.0×In) and instantaneous magnetic (5–10×In) trip dials, delivering up to 100 kA Icu / 85 kA Ics per IEC/EN 60947-2.

Frame Range
125–2000 A (8 Frames)
Adjustment Dials
Thermal 0.8–1.0×In · Mag 5–10×In
Max Breaking (400V)
Up to 100 kA Icu / 85 kA Ics
Standards & Ui
IEC 60947-2 · Ui 1000 V / 8 kV

Ikhtisar

The VIOX VM6RT Series (including VM6RT double-adjustable, VM6RT/A thermal-adjustable, and VM6RT/P magnetic-adjustable) bridges fixed thermomagnetic breakers and electronic trip units across 8 industrial frames from 125 A to 2000 A (16 A–1600 A rated current, 3P/4P, AC 400 V). Front-mounted rotary dials let panel builders fine-tune thermal overload protection from 0.8–1.0×In and instantaneous magnetic tripping from 5–10×In on site, simplifying spare-part inventory and feeder selectivity up to 100 kA Icu / 85 kA Ics.

Fitur

  • Field-adjustable thermal overload setting (0.8–1.0×In) and adjustable magnetic instantaneous pickup (5–10×In).
  • 8 industrial frames from VM6RT/A-125 through VM6RT-2000 (16 A–1600 A rated currents, 3P/4P).
  • Breaking capacity up to 100 kA Icu / 85 kA Ics at AC 400 V (VM6RT-2000H) and 85 kA Icu / 65 kA Ics (800/1250 A H).
  • Multi-contact blade design delivers low temperature rise and compact enclosure footprint.
  • Ui 1000 V, Uimp 8 kV, Selectivity Category Class A per IEC/EN 60947-2.
  • Full compatibility with DC3/DC6 motor operators, rotary handles, plug-in/draw-out bases, and internal codes 00–78.

Model

Frame SeriesRated Current In (A)Breaking TiersPolandiaMax Icu / Ics (400 V AC)
VM6RT/A-12516, 20, 25, 32, 40, 50, 63, 80, 100, 125 AC, S, M, H3P, 4P50 kA / 50 kA
VM6RT-16025, 32, 40, 50, 63, 80, 100, 125, 140, 160 AC, S, M, H3P, 4P50 kA / 50 kA
VM6RT-250100, 125, 140, 160, 180, 200, 225, 250 AC, S, M, H3P, 4P50 kA / 50 kA
VM6RT-400315, 320, 350, 400 AM, H3P, 4P50 kA / 50 kA
VM6RT-630400, 500, 630 AM, H3P, 4P50 kA / 50 kA
VM6RT-800630, 700, 800 AM, H3P, 4P85 kA / 65 kA
VM6RT-12501000, 1250 AM, H3P, 4P85 kA / 65 kA
VM6RT-20001600 AM, H3P, 4P100 kA / 85 kA

Spesifikasi

Breaking Capacity (AC 400 V)

Frame & TiersIcs (400 V)Icu (400 V)Rentang Penyesuaian
VM6RT/A-125 C / S / M / H5 / 10 / 18 / 50 kA10 / 20 / 36 / 50 kAThermal 0.8–1.0×In
VM6RT-160 C / S / M / H5 / 10 / 10 / 50 kA8 / 20 / 20 / 50 kAThermal 0.8–1.0×In · Mag 5–10×In
VM6RT-250 C / S / M / H5 / 8 / 10 / 50 kA8 / 15 / 20 / 50 kAThermal 0.8–1.0×In · Mag 5–10×In
VM6RT-400 / 630 M / H50 / 50 kA50 / 50 kAThermal 0.8–1.0×In · Mag 5–10×In
VM6RT-800 / 1250 M / H50 / 65 kA65 / 85 kAThermal 0.8–1.0×In · Mag 5–10×In
VM6RT-2000 M / H50 / 85 kA50 / 100 kAThermal 0.8–1.0×In · Mag 5–10×In

Outline Dimensions (mm)

BingkaiPolandiaWidth W (mm)Length L (mm)Height Cover / Handle (mm)
VM6RT/A-1253P / 4P75 / 10013068 / 94.5
VM6RT-1603P / 4P90 / 12015568–82 / 94–108
VM6RT-2503P / 4P105 / 14016568–88 / 96–116
VM6RT-400 / 6303P / 4P140 / 184257103 / 152
VM6RT-800 / 12503P / 4P210 / 280275.5103 / 152
VM6RT-20003P / 4P210 / 280340141 / 244

External Accessories Compatibility

AksesoriSupported Frames & Poles
Electric Motor Operation3P, 4P
Manual Rotary Handle (ZY1/ZF1/ZY2/ZF2/Z3)3P, 4P
Extension Copper Bar (P)3P, 4P
Interlocking Mekanis3P, 4P (up to 800 A)
Plug-in Front / Back Panel (Z2Q/Z2H/Z3Q/Z3H)3P, 4P (up to 800 A)
Draw-out Back-Panel (DR)400 / 630 / 800 A (3P only)

Panduan Pemilihan

Posisi KodeArtiCatalog Value or Options
VM6RT / RT-A / RT-PSeriDouble-adjustable (RT), thermal-adjustable (RT-A), or magnetic-adjustable (RT-P)
125–2000Arus rangka125 (RT/A only), 160, 250, 400, 630, 800, 1250, 2000 A
C / S / M / HBreaking tierC/S/M/H on 125–250 A; M/H on 400–2000 A
3 / 4Polandia3P or 4P (Neutral Types A, B, C, D)
00–78Internal accessory code00 None · 08 Alarm · 10 Shunt · 18 Shunt+Alarm · 20/27 Aux · 28/29 Aux+Alarm · 30 UVT · 38 UVT+Alarm · 40/41/48 Shunt+Aux · 50 Shunt+UVT · 60–69 Multi-Aux · 70–78 UVT+Aux (DC 24/110/220 V, AC 230/400 V)

1. Tune to Actual Load

Dial thermal Ir (0.8–1.0×In) to match cable ampacity or seasonal load growth without swapping breakers.

2. Coordinate Inrush

Set magnetic pickup (5–10×In) above motor or transformer starting inrush while keeping fast fault clearance.

3. Reduce SKU Stock

One adjustable VM6RT frame replaces multiple fixed-rating spares for distributors and panel shops.

4. Add Switchgear Kits

Pair with rotary handles, DC3/DC6 motor operators, or plug-in/draw-out bases.

Instalasi

  • Adjust the front thermal (0.8–1.0×In) and magnetic (5–10×In) dials with a flathead driver before energizing.
  • Seal the transparent dial cover after commissioning to prevent unauthorized field tampering.
  • Verify frame cutout dimensions (same footprint as VM6 standard series across all 8 frames).
  • Compare with fixed VM6 or electronic VM6E on our MCCB hub.

PERTANYAAN YANG SERING DIAJUKAN

What is the difference between VM6RT, VM6RT-A, and VM6RT-P?

VM6RT provides double adjustment (both thermal 0.8–1.0×In and magnetic 5–10×In); VM6RT-A provides thermal adjustment only (including the 125 A frame); VM6RT-P provides magnetic adjustment only.

Why choose an adjustable thermomagnetic MCCB over a fixed MCCB?

Adjustable dials let engineers tune overload pickup to exact cable ampacity and adjust magnetic pickup for motor inrush, while allowing distributors to stock fewer SKUs.

Does VM6RT share the same mounting footprint as VM6?

Yes. Every VM6RT frame from 125 A to 2000 A shares the exact same W × L × H outline dimensions and external accessory ecosystem as VM6.

What is the maximum breaking capacity of VM6RT?

At AC 400 V, VM6RT reaches 50 kA Icu/Ics up to 630 A, 85 kA Icu / 65 kA Ics on 800–1250 A, and 100 kA Icu / 85 kA Ics on VM6RT-2000H.

Are plug-in and draw-out bases supported on VM6RT?

Yes. Plug-in front/back bases are available from 125 A to 800 A (3P/4P), and draw-out back-panel bases are supported on 400, 630, and 800 A (3P).

Can VM6RT be equipped with shunt and undervoltage releases?

Yes. All internal accessory combinations (codes 08–78) are factory-installable in DC 24/110/220 V and AC 230/400 V.

2026 Technical Catalog · Online PDF
VIOX Full 18-Series MCCB & Intelligent Breaker Catalog
Open the complete 18-series catalog online for frame dimensions, time-current trip curves, wiring schematics, and factory order codes (PDF · 26.7 MB).
Open Full Catalog PDF ↗

Butuh Penawaran Produk?
Mari Kita Bangun Bersama.

Kirimkan model produk, peringkat teknis, kuantitas, dan persyaratan OEM kepada kami. Tim kami akan meninjau aplikasi Anda dan merespons dalam satu hari kerja.