VIOX ELECTRIC
Bahasa

VIOX VM6E Series Electronic MCCB (160A–2000A, Class B)

VIOX VM6E Series Electronic MCCB spans 7 frames from 160 A to 2000 A (3P/4P, AC 400 V / 690 V, 50/60 Hz, Ui 1000 V, Uimp 8 kV) with wide 0.4–1.0×In electronic trip adjustment (3-knob or 6-knob), Class B short-time withstand (Icw 10–20 kA/1s), and breaking capacity up to 100 kA Icu / 85 kA Ics.

Frame Range
160–2000 A (7 Frames)
Perjalanan Elektronik
0.4–1.0×In · 3 or 6 Knobs
Class B Icw
10 kA/1s (400–630) · 20 kA/1s (800+)
Max Breaking (400V)
Up to 100 kA Icu / 85 kA Ics

Ikhtisar

The VIOX VM6E Series is a microprocessor-based electronic molded case circuit breaker engineered for high-selectivity industrial switchgear across AC 400 V and AC 690 V networks (50/60 Hz). Spanning 7 frames from 160 A to 2000 A (12 A–2000 A adjustable, 3P/4P), VM6E delivers Class B selectivity with rated short-time withstand current Icw up to 20 kA/1s, 3-knob or 6-knob LSIG protection, optional ground-fault (Code G), overload-alarm-without-trip (Code III), thermomagnetic dual backup (Code R), and low-temperature-rise builds (40 K / 50 K / 60 K).

Fitur

  • Wide 0.4–1.0×In electronic current adjustment (12 A to 2000 A) with 3-knob or 6-knob precision settings.
  • True Class B selectivity (400–2000 A): Icw = 10 kA/1s (400–630 A) and 20 kA/1s (800–2000 A).
  • Dual-voltage AC 400 V / AC 690 V operation (50/60 Hz) with up to 100 kA Icu / 85 kA Ics at 400 V.
  • Optional grounding protection (Code G), overload alarm without trip (Code III), and dual electronic + thermomagnetic backup (Code R).
  • Low-temperature-rise options: Type V (40 K), Type VI (50 K), and Type VII (60 K).
  • Full compatibility with DC3/DC6 motor operators, rotary handles, plug-in/draw-out bases, and internal accessory codes 00–78.

Model

Frame SeriesAdjustable In Range (A)Breaking TiersIcw (1s) & CategoryMax Icu / Ics (400 V AC)
VM6E-16012–32 A · 40–100 A · 63–160 AS, M, HKelas A65 kA / 65 kA
VM6E-250100–250 AS, M, HKelas A65 kA / 65 kA
VM6E-400160–400 A · 200–400 AM, H10 kA/1s · Class B70 kA / 70 kA
VM6E-630250–630 A · 400–630 AM, H10 kA/1s · Class B70 kA / 70 kA
VM6E-800400–630 A · 500–800 AM, H20 kA/1s · Class B65 kA / 50 kA
VM6E-1250630–1000 A · 850–1250 AM, H20 kA/1s · Class B65 kA / 50 kA
VM6E-2000500–1250 A · 630–1600 A · 800–2000 AM, H20 kA/1s · Class B100 kA / 85 kA

Spesifikasi

Electrical & Breaking Capacity (400 V / 690 V AC)

Frame & TiersIcs (400 V / 690 V)Icu (400 V / 690 V)Icw (1s)
VM6E-160 S / M / H18 / 35 / 65 kA · 4 / 8 / 8 kA25 / 50 / 65 kA · 8 / 8 / 8 kA—
VM6E-250 S / M / H18 / 35 / 65 kA · 8 / 8 / 8 kA25 / 50 / 65 kA · 4 / 8 / 8 kA—
VM6E-400 M / H35 / 70 kA · 8 / 8 kA50 / 70 kA · 8 / 8 kA10 kA/1s
VM6E-630 M / H35 / 70 kA · 8 / 8 kA50 / 70 kA · 8 / 8 kA10 kA/1s
VM6E-800 M / H50 / 50 kA · 10 / 10 kA65 / 65 kA · 20 / 20 kA20 kA/1s
VM6E-1250 M / H50 / 50 kA · 10 / 10 kA65 / 65 kA · 20 / 20 kA20 kA/1s
VM6E-2000 M / H50 / 85 kA · 20 / 20 kA50 / 100 kA · 20 / 20 kA20 kA/1s

Outline Dimensions (mm)

BingkaiPolandiaWidth W (mm)Length L (mm)Height Cover / Handle (mm)
VM6E-1603P / 4P90 / 12015568–82 / 94–108
VM6E-2503P / 4P105 / 14016568–88 / 96–116
VM6E-400 / 6303P / 4P140 / 184257103 / 152
VM6E-800 / 12503P / 4P210 / 280275.5103 / 152
VM6E-20003P / 4P210 / 280340141 / 244

External Accessories Compatibility

AksesoriSupported Frames & Poles
Electric Motor Operation3P, 4P
Manual Rotary Handle (ZY1/ZF1/ZY2/ZF2/Z3)3P, 4P
Extension Copper Bar (P)3P, 4P
Interlocking Mekanis3P, 4P (up to 800 A)
Plug-in Front / Back Panel (Z2Q/Z2H/Z3Q/Z3H)3P, 4P (up to 800 A)
Draw-out Back-Panel (DR)400 / 630 / 800 A (3P only)

Panduan Pemilihan

Posisi KodeArtiCatalog Value or Options
VM6ESeriElectronic molded case circuit breaker (IEC/EN 60947-2)
160–2000Arus rangka160, 250, 400, 630, 800, 1250, 2000 A
3 / 6Knob configuration3 knobs (LSI basic) or 6 knobs (full LSIG + time delays)
G / III / R / VAdditional functionsG: Ground fault · III: Overload alarm w/o trip · R: Thermomagnetic backup · V/VI/VII: 40K/50K/60K low temp rise
3 / 4Polandia3P or 4P (Neutral Types A, B, C, D)
00–78Internal accessory code00 None · 08 Alarm · 10 Shunt · 18 Shunt+Alarm · 20/27 Aux · 28/29 Aux+Alarm · 30 UVT · 38 UVT+Alarm · 40/41/48 Shunt+Aux · 50 Shunt+UVT · 60–69 Multi-Aux · 70–78 UVT+Aux (DC 24/110/220 V, AC 230/400 V)

1. Select Knob Depth

Choose 3-knob electronic trip for standard feeders or 6-knob LSIG for full time-graded selectivity.

2. Leverage Class B Icw

Use 10–20 kA/1s short-time delay on 400–2000 A main incoming MCCBs to coordinate with downstream breakers.

3. Specify Ground Fault

Add Code G for integrated ground-fault protection or Code R for dual electronic + thermomagnetic redundancy.

4. Consolidate Spares

0.4–1.0×In wide dial range lets one VM6E-400 or VM6E-630 cover an entire sub-panel spectrum.

Instalasi

  • Verify short-time delay (tsd) settings against upstream ACB and downstream MCB/MCCB coordination curves.
  • Confirm 50/60 Hz AC 400 V or AC 690 V rated voltage and prospective fault level.
  • Select Code V (40 K) or VI (50 K) low-temperature-rise builds for IP54/IP65 sealed switchgear.
  • Compare with LCD metering VM6EY or thermomagnetic VM6 on our MCCB page.

PERTANYAAN YANG SERING DIAJUKAN

Why is Class B selectivity (Icw 10–20 kA/1s) important on VM6E?

Class B MCCBs can withstand a short-circuit current for a programmable short-time delay (up to 1 second) without tripping instantaneously, allowing downstream branch breakers to clear the fault first and preventing upstream blackouts.

What is the difference between 3-knob and 6-knob VM6E trip units?

3-knob units provide compact Ir/Isd/Ii current settings, while 6-knob units add programmable long-delay/short-delay time settings and optional ground-fault protection for complex switchgear.

Does VM6E support both 400 V and 690 V AC?

Yes. All 7 VM6E frames (160 A to 2000 A) are rated for both AC 400 V and AC 690 V at 50/60 Hz with Ui = 1000 V and Uimp = 8 kV.

What does Additional Function Code R mean on VM6E?

Code R equips the VM6E with dual electronic + thermomagnetic protection for maximum reliability in critical industrial feeders.

What is the adjustable current range of VM6E?

Every VM6E frame is field-adjustable from 0.4 to 1.0×In—spanning 12 A on VM6E-160 up to 2000 A on VM6E-2000.

Are draw-out bases available for VM6E?

Yes. Draw-out back-panel bases are supported on VM6E-400, VM6E-630, and VM6E-800 (3P), and plug-in bases are supported from 160 A to 800 A (3P/4P).

2026 Technical Catalog · Online PDF
VIOX Full 18-Series MCCB & Intelligent Breaker Catalog
Open the complete 18-series catalog online for frame dimensions, time-current trip curves, wiring schematics, and factory order codes (PDF · 26.7 MB).
Open Full Catalog PDF ↗

Butuh Penawaran Produk?
Mari Kita Bangun Bersama.

Kirimkan model produk, peringkat teknis, kuantitas, dan persyaratan OEM kepada kami. Tim kami akan meninjau aplikasi Anda dan merespons dalam satu hari kerja.

Minta Penawaran