VIOX ELECTRIC
زبان

کنتاکتور AC با کویل الکترونیکی VIOX CJX2s-W

Electronic-coil AC contactors for motor starting and control.

  • 9–95 A AC-3 at 380/400 V
  • 4–45 kW motor ratings at 380/400 V
  • AC/DC control coil options: 24 V, 48 V or 100–240 V
  • 690 V rated insulation voltage; rail or screw mounting

نمای کلی

VIOX CJX2s-W electronic-coil AC contactors are designed for frequent
AC motor starting and control, remote circuit switching and use with
suitable thermal overload relays. The series covers 9–95 A AC-3 at
380/400 V and uses an electronic electromagnetic control system with
AC/DC coil supply options.

ویژگی‌ها

  • Electronic coil control with a built-in circuit board.
  • AC/DC control supply options: 24 V, 48 V or 100–240 V, depending on
    the selected coil.
  • Holding consumption of ≤5 VA as listed in the specification
    table.
  • Rail or screw mounting with model-specific dimensions.
  • CJX2s platform accessories available for matching
    پیکربندی ها.

مشخصات فنی

مدل AC-3 current at 380/400 V AC-3 motor power at 380/400 V
CJX2s-W09 9 A 4 kW
CJX2s-W12 12 A 5.5 kW
CJX2s-W18 18 A 7.5 kW
CJX2s-W25 25 آمپر 11 کیلووات
CJX2s-W32 32 آمپر 15 kW
CJX2s-W38 38 A 18.5 kW
CJX2s-W40 40 آمپر 18.5 kW
CJX2s-W50 50 آمپر 22 کیلووات
CJX2s-W65 65 A 30 kW
CJX2s-W80 80 A 37 kW
CJX2s-W95 95 آمپر 45 kW
پارامتر مشخصات
Main poles in the detailed rating table 3P
ولتاژ عایق نامی رابط کاربر 690 V
Rated main-circuit operating voltages in the table 380/400 V; 660/690 V
Rated control circuit voltage Us AC/DC: 24 V, 48 V, 100–240 V options
Control circuit operating range 85%–110% Us
Release range 20%–80% Us
Coil holding consumption ≤5 VA
Auxiliary contact configurations 1NO / 1NC
Protection, CJX2s-W09–W38 IP20، به استثنای ترمینال‌ها
Protection, CJX2s-W40–W95 آی پی ۱۰
دسته بندی نصب سوم
درجه آلودگی 3

The motor ratings above apply to AC-3 at 380/400 V. Other voltages
and utilization categories have different ratings. Select the control
coil independently of the main-circuit voltage; the AC/DC coil rating
does not establish a DC main-circuit switching rating.

ابعاد

The supplied drawing separates CJX2s-W09–W38 and CJX2s-W40–W95
mounting layouts. Use the dimensions for the exact model and any fitted
accessories.

CJX2s-W electronic-coil AC contactor installation dimensions

اطلاعات سفارش

Specify the CJX2s-W model, motor voltage and power, utilization
category, AC or DC control supply and its voltage, auxiliary-contact
configuration, accessories and quantity when requesting a quotation.

نیاز به استعلام قیمت محصول دارید؟
بیایید با هم بسازیم.

مدل محصول، مشخصات فنی، تعداد و الزامات OEM خود را برای ما ارسال کنید. تیم ما درخواست شما را بررسی کرده و ظرف یک روز کاری پاسخ خواهد داد.

درخواست قیمت