نمای کلی
VOSA4-PK-1500V VIOX 1500V DC 250kA Semiconductor Protection Fuse: aR class for 800A-2000A DC links with ≤5ms time constant, pre-arcing I²t from 174000 A²s, IEC 60269-4 and GB/T 13539.4. Built for storage, solar, rail and metallurgy converters.
Clearing a DC fault on a 2000A link leaves no room for a slow element, because the energy released scales with both current and the circuit time constant. VIOX Electric answers that with the 1500V DC 250kA Semiconductor Protection Fuse, an aR-class device rated to interrupt 250kA on circuits whose time constant reaches just 5ms. It protects IGBT modules, thyristors and rectifier diodes in solar and wind stations, battery storage power blocks, rail traction converters, metallurgy plants and utility DC equipment.
ویژگیها
- Rated voltage 1500VDC and current capacity 800A for ess & semiconductor high-speed fuse applications.
- High interrupting performance (250kA) with rapid current-limiting fault clearing.
- Engineered and tested in accordance with GB/T 13539.4 / GB/T13539.4 / IEC 60269-4 standards.
- Precision-engineered low-power-loss silver-plated contacts and high-temperature ceramic or flame-retardant housing.
- Direct OEM replacement geometry for standardized industrial, solar PV, ESS, and EV protection panels.
مشخصات
VOSA4-PK-1500V Technical Specifications
| شماره سریال | Rated Current A | Pre-arcing I²t A²s | Melting I²t A²s | Power dissipation W |
| 1 | 800 | 174000 | 878000 | 248 |
| 2 | 1000 | 286000 | 1855000 | 265 |
| 3 | 1250 | 684000 | 3154000 | 279 |
| 4 | 1400 | 1030000 | 4478000 | 295 |
| 5 | 1600 | 1315000 | 7093000 | 315 |
| 6 | 1800 | 2321000 | 9920000 | 328 |
| 7 | 2000 | 3475000 | 13710000 | 345 |
VOSA4-PK-1500V Ratings & Dimensions Table 2
| Rated Current (A) | Conventional Time (h) | Conventional Current | |
| “gR” | |||
| Inf | lf | ||
| ln≤63 | 1 | 1.13ln | 1.6ln |
| 63<In≤160 | 2 | ||
| 160<ln≤400 | 3 | ||
| 400<ln | 4 | ||
| Note:ln is the rated current of the fuse; lnf is the conventional non-fusing current; if is the conventional fusing current. | |||
Selection & Installation Notes
- Verify system maximum voltage (1500VDC) and prospective short-circuit fault current before selecting the fuse link or holder rating.
- Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
- Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
- Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.
سوالات متداول
What voltage and current ratings does the VIOX VOSA4-PK-1500V 1500V DC 250kA Semiconductor Protection Fuse support?
This VIOX VOSA4-PK-1500V series is rated for 1500VDC with a current rating of 800A and 250kA breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.
Which international standards apply to VIOX VOSA4-PK-1500V 1500V DC 250kA Semiconductor Protection Fuse?
The VOSA4-PK-1500V series is designed and verified to GB/T 13539.4 / GB/T13539.4 / IEC 60269-4 requirements for safe overcurrent and short-circuit protection.
Where is the VIOX VOSA4-PK-1500V 1500V DC 250kA Semiconductor Protection Fuse typically installed?
It is engineered for ess & semiconductor high-speed fuse circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.
Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?
Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.