ASTP-Y Ρελέ χρόνου
The VIOX ASTP-Y Analog Timer is a reliable and precise time delay relay designed for industrial automation systems and mechanical devices. This device counts down the set time and then switches the relay contacts, maintaining this position until reset. It features a time range of 0-60 seconds, adjustable via an analog dial, and is suitable for various applications requiring accurate timing control.
Στείλτε τις απαιτήσεις σας, θα σας παραθέσουμε εντός 12 ωρών
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:sales@viox.com
VIOX ASTP-Y Analog Timer
Επισκόπηση
The VIOX ASTP-Y Analog Timer is a reliable and precise time delay relay designed for industrial automation systems and mechanical devices. This device counts down the set time and then switches the relay contacts, maintaining this position until reset. It features a time range of 0-60 seconds, adjustable via an analog dial, and is suitable for various applications requiring accurate timing control.
Βασικά χαρακτηριστικά
- Precise Timing Control: Adjustable time range from 0 to 60 seconds with an analog dial.
- Reliable Operation: Switches relay contacts after the set time and maintains the position.
- Dual Relay Outputs: Two relay outputs with a maximum load of 5A each.
- Εύκολη εγκατάσταση: Includes PF083A base for DIN rail mounting.
- Οπτικοί δείκτες: Front panel work indicator for easy monitoring.
- Ανθεκτική κατασκευή: Designed for long-lasting performance with high mechanical and electrical life.
- Ευρύ φάσμα τάσης: Operates on 230 VAC with a tolerance of +/-10%.
Προδιαγραφές
CLASSIFICATION | TIMER | TIMER | ||||||
ΜΟΝΤΕΛΟ | ASTP-N | ASTP-Y | AH2-N | AH2-Y | ||||
APPEARANCE | ||||||||
DIMENSIONS | 61H×49W×70D | 88H×58W×68D | 61H×49W×70D | 88H×58W×68D | ||||
MOUNTING & SOCKET |
SURFACE(-N) | PF083A(E) PS-08 | PF083A(E) PS-08 | |||||
FLUSH(-Y) | US-08 P3G-08 | US-08 P3G-08 | ||||||
FULL TIMING RANGE | SEC:1,3,6,10,12,30,60 MIN:3,6,12,30,60 HR:3,6,12,24 |
SEC:1,3,6,12,30,60 MIN:3,6,12,30,60 HR:3,6,12,24 |
||||||
RATED VOLTAGE | DC(V):12,24 AC(V):12,24,110,220,240, 50/60Hz | DC(V):12,24 AC(V):12,24,110,220,240, 50/60Hz | ||||||
INDICATOR OPERATING | Time Operating | ON-UP Two indicator Lamp ON-UP | ||||||
CONTACT | ΜΟΝΤΕΛΟ | ASTP-N1/ ASTP-Y1 | ASTP-N2/ ASTP-Y2 | ASTP-N/ ASTP-Y | AH2-N1/ AH2-Y1 | AH2-N2/ AH2-Y2 | AH2-N/ AH2-Y | |
TIME LIMIT 1C | 5A | 5A | 5A | 5A | ||||
TIME LIMIT 2C | 5A | 5A | ||||||
INSTANTANEOUS 1C | 5A | 5A | ||||||
LIFE | MECHANICAL | 5×106 φορές | 5×106 φορές | |||||
ELECTRICAL | 105 φορές | 105 φορές | ||||||
ACCURACY | REPEAT ERROR | ±1% max | ±1% max | |||||
SETTING ERROR | ±10% max | ±10% max | ||||||
VOLTAGE ERROR | ±1% max | ±1% max | ||||||
TEMP. ERROR | ±2% max | ±2% max | ||||||
RESET TIME | 0.1 sec max | 0.1 sec max | ||||||
CONSUMED POWER | 2VA | 3VA | ||||||
AMBIENT TEMPERATURE | -10℃~+55℃ | -10℃~+55℃ | ||||||
AMBIENT HUMIDITY | 48~85%RH | 48~85%RH | ||||||
WEIGHT | 220g | 220g | ||||||
CONNECTION DIAGRAMS & TIMING CHART | 39A | 39B | 39C | 39D | 39E | 39F |
Εφαρμογές
The VIOX ASTP-Y Analog Timer is ideal for a variety of applications in industrial automation and mechanical devices. It is suitable for use in control panels, machinery, and other systems requiring precise timing control. The timer’s robust design and reliable performance make it an excellent choice for both commercial and industrial environments.
Τεχνικά στοιχεία
- Τροφοδοσία ρεύματος: 230 VAC +/-10%
- Output: Ρελέ
- Max. Load: 5A
- Εύρος χρόνου: 0-60 seconds
- Διαστάσεις: 40×50 mm
- Assembly: DIN Rail, In the table
- Ψήφισμα: Analog Dial
- Degree of Protection: IP 40
- Μηχανική διάρκεια ζωής: 5×106 φορές
- Ηλεκτρική ζωή: 105 φορές
- Ακρίβεια: Repeat Error: ±1% Max., Setting Error: ±10% Max., Voltage Error: ±1% Max., Temp. Error: ±2% Max.
- Reset Time: 0.1 Sec. Max.
- Κατανάλωση ενέργειας: 2VA
- Θερμοκρασία περιβάλλοντος: -10℃ to +55℃
- Υγρασία περιβάλλοντος: 48% to 85% RH
- Βάρος: 220g
Διάγραμμα σύνδεσης
The VIOX ASTP-Y Analog Timer features a straightforward connection diagram for easy installation. The device starts counting the set time when the power supply voltage is applied, then switches the relay contacts and remains in this position. Relay A1 operates according to the set time on the panel, while Relay A2 operates according to the timer power supply.
Output Modes
When the power supply voltage is applied, the device starts counting the set time and then switches the relay contacts, maintaining this position. Relay A1 works according to the set time on the panel, and Relay A2 works according to the timer power supply. Below is the operation diagram: