| Modell | LM8 | |||
| Dimension | ![]() |
|||
| Entfernung wahrnehmen | 1mm±10% | |||
| Bündiger Typ | DC10~30VDC | NPN | NO | LM8-3001NA |
| NC | LM8-3001NB | |||
| NO+NC | LM8-3001NC | |||
| PNP | NO | LM8-3001PA | ||
| NC | LM8-3001PB | |||
| NO+NC | LM8-3001PC | |||
| Zwei-Draht-System | NO | LM8-3001LA | ||
| NC | LM8-3001LB | |||
| AC90~250VAC | NO | LM8-2001A | ||
| NC | LM8-2001B | |||
| NO+NC | LM8-2001C | |||
| Entfernung wahrnehmen | 2mm±10% | |||
| Nicht bündiger Typ | DC10~30VDC | NPN | NO | LM8-3002NA |
| NC | LM8-3002NB | |||
| NO+NC | LM8-3002NC | |||
| PNP | NO | LM8-3002PA | ||
| NC | LM8-3002PB | |||
| NO+NC | LM8-3002PC | |||
| Zwei-Draht-System | NO | LM8-3002LA | ||
| NC | LM8-3002LB | |||
| AC90~250VAC | NO | LM8-2002A | ||
| NC | LM8-2002B | |||
| NO+NC | LM8-2002C | |||
| Ausgangsstrom | DC | 200mA | ||
| AC | / | |||
| Spitze der Ausgangsspannung | DC-Typ unter 3V、Zweidraht-Typ unter 3,9V、 AC unter l0V DC<3V, AC<10V | |||
| Verbrauchsstrom | DC-Typ 8mA bei 12V, 15mA bei 24V, AC unter 10mA DC<15mA, AC<10mA | |||
| Standard erkanntes Objekt | 8×8×1 (A3-Eisen) | |||
| Reproduzierbarkeit | 0.01 | |||
| Antwortfrequenz | 500Hz/25Hz | |||
| Temperatur in der Umgebung | -25℃-+75℃ | |||
| Isolationswiderstand | ≥50MΩ | |||
| Material der Schale | Metall | |||
| Schutzgrad | IP67 | |||