VIOX ELECTRIC
Jazyk

VIOX VOPV-40 1500VDC 40A 14×51mm Solar PV Thermal Fuse Link

VOPV-40 1500VDC Solar PV Fuse Link is specifically designed to protect and isolate the Solar Photovoltaic (PV) system. This 14×51mm compact cylindrical fuse secures the 1500VDC Photovoltaic (PV) systems. 1500VDC 40A 14×51mm Solar PV Thermal Fuse Link provides multiple ampere ratings.

Řada VIOX
VOPV-40
Jmenovité napětí
1500VDC
Jmenovitý proud
40A
Standardní
GB/T 13539.6 / IEC60269-6

Přehled

VOPV-40 1500VDC Solar PV Fuse Link is specifically designed to protect and isolate the Solar Photovoltaic (PV) system. This 14×51mm compact cylindrical fuse secures the 1500VDC Photovoltaic (PV) systems. 1500VDC 40A 14×51mm Solar PV Thermal Fuse Link provides multiple ampere ratings of 10A to 40A and is capable of interrupting overload currents associated with malfunctioning Photovoltaic (PV) systems. VIOX Electric is a leading manufacturer of Solar Photovoltaic (PV) Fuses in China, dedicated to providing safer circuit protection for our customers.

1500VDC 40A 14×51mm Solar PV Thermal Fuse Link

Funkce

  • Rated voltage 1500VDC and current capacity 40A for solar pv protection fuse applications.
  • High interrupting performance (25kA) with rapid current-limiting fault clearing.
  • Engineered and tested in accordance with GB/T 13539.6 / IEC60269-6 standards.
  • Precision-engineered low-power-loss silver-plated contacts and high-temperature ceramic or flame-retardant housing.
  • Direct OEM replacement geometry for standardized industrial, solar PV, ESS, and EV protection panels.

Specifikace

VOPV-40 Technical Specifications

Product code Jmenovitý proud Vypínací schopnost Safety certificate Power loss 1.0In(W) Net weight
VOPV40/10NF 10A 1500Vdc TUV&CE:25kA ● ● ○ 1.7 24.5g
VOPV40/12NF 12A ● ● ○ 2.0
VOPV40/15NF 15A ● ● ○ 2.5
VOPV40/20NF 20A ● ● ○ 3.0
VOPV40/25NF 25A ● ● ○ 3.9
VOPV40/32NF 32A ● ● ○ 5.0
VOPV40/40NF 40A ● ● ○ 6.3

VOPV-40 Ratings & Dimensions Table 2

Standard:IEC60269-6 & GB/T 13539.6
113% In 145% In
>1h non fusing <1h fusing

Selection & Installation Notes

  • Verify system maximum voltage (1500VDC) and prospective short-circuit fault current before selecting the fuse link or holder rating.
  • Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
  • Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
  • Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.

ČASTO KLADENÉ DOTAZY

What voltage and current ratings does the VIOX VOPV-40 1500VDC 40A 14×51mm Solar PV Thermal Fuse Link support?

This VIOX VOPV-40 series is rated for 1500VDC with a current rating of 40A and 25kA breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.

Which international standards apply to VIOX VOPV-40 1500VDC 40A 14×51mm Solar PV Thermal Fuse Link?

The VOPV-40 series is designed and verified to GB/T 13539.6 / IEC60269-6 requirements for safe overcurrent and short-circuit protection.

Where is the VIOX VOPV-40 1500VDC 40A 14×51mm Solar PV Thermal Fuse Link typically installed?

It is engineered for solar pv protection fuse circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.

Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?

Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.

Potřebujete cenovou nabídku produktu?
Pojďme to vybudovat společně.

Zašlete nám model produktu, technické parametry, množství a požadavky OEM. Náš tým vaši žádost posoudí a odpoví do jednoho pracovního dne.

Požádat o cenovou Nabídku