ទិដ្ឋភាពទូទៅនៃផលិតផល
The VIOX NTS01/NTS10 cabinet thermostat series regulates temperature inside electrical enclosures, control cabinets, and industrial panels. Its compact 18mm-wide housing mounts on a standard 35mm DIN rail, helping panel builders control heaters, fans, cooling devices, warning lights, and alarm circuits from one adjustable thermostat platform.
The series provides two contact functions for different control tasks. NTS01-60 uses a normally closed contact for heating and anti-condensation control. NTS10-60 uses a normally open contact for cooling, ventilation, and signaling. Both models cover a 0 to +60°C setting range.
ជម្រើសម៉ូដែល
| គំរូ | ប្រភេទទំនាក់ទំនង | ទម្រង់ទំនាក់ទំនង | កម្មវិធីចម្បង |
|---|---|---|---|
| NTS01-60 | SPST-NC | បិទធម្មតា | ឧបករណ៍កម្តៅ និងការគ្រប់គ្រងសំណើម |
| NTS10-60 | SPST-NO | បើកធម្មតា | ម៉ាស៊ីនត្រជាក់ ឧបករណ៍ត្រជាក់ ភ្លើងសញ្ញា និងការគ្រប់គ្រងសំឡេងរោទិ៍ |
លក្ខណៈសំខាន់ៗ
- ឧបករណ៍កម្តៅពីរកំណែសម្រាប់ការគ្រប់គ្រងកំដៅ និងត្រជាក់
- ជួរកំណត់សីតុណ្ហភាពពី 0 ទៅ +60°C
- Compact 18mm-wide design for electrical cabinet installation
- 35mm DIN rail mounting according to EN 60715
- Bimetal thermostat element for temperature sensing and switching
- សាកសមសម្រាប់កំដៅ ម៉ាស៊ីនត្រជាក់ត្រង ឧបករណ៍ត្រជាក់ និងសញ្ញាសំឡេងរោទិ៍
- Flexible mounting position inside enclosures and control panels
លក្ខណៈបច្ចេកទេស
| ប៉ារ៉ាម៉ែត្រ | ការបញ្ជាក់ |
|---|---|
| Temperature setting range | 0 ទៅ +60°C |
| Switching difference | 7K (+/−4K) |
| Temperature sensor | ធាតុឧបករណ៍កម្តៅ Bimetal |
| ភាពធន់នឹងទំនាក់ទំនង | ≤50mΩ |
| អាយុកាលសេវាកម្ម | >100,000 វដ្ត |
| ការវាយតម្លៃទំនាក់ទំនង | 10(2)A at 250VAC; 15(2)A at 120VAC; 30W at DC24V to 72V |
| Connection terminal | ស្ថានីយវីស 2 ប៉ូល |
| Rigid wire capacity | 2.5 មម 2 |
| Flexible wire capacity | 1.5mm² ជាមួយ ferrule |
| វិធីសាស្ត្រម៉ោន | 35mm DIN rail, EN 60715 |
| សម្ភារៈប្រអប់ | ABS ពណ៌ប្រផេះដែលធន់នឹងអណ្តាតភ្លើង |
| វិមាត្រ | 86 × 48 × 18mm |
| ទីតាំងដំឡើង | ទីតាំងណាមួយ |
| សីតុណ្ហភាពព័ទ្ធជុំវិញ | −45°C to +80°C |
| សំណើមព័ទ្ធជុំវិញ | ≤90% RH, មិន condensation |
| កំរិតការពារ | IP20 |
| ទម្ងន់ | ប្រហែល 40g |
How the Two Models Work
Choose the contact function according to the equipment that must switch when enclosure temperature moves below or above the selected setpoint.
NTS01-60: Heating Control
The normally closed contact is used with heaters and anti-condensation equipment. When enclosure temperature falls below the set value, the circuit supports heating or dehumidification control.
NTS10-60: Cooling and Signaling
The normally open contact is used with fans, cooling equipment, warning lights, and alarms. When enclosure temperature rises above the set value, it can activate ventilation, cooling, or signaling equipment.
កម្មវិធី
Typical enclosure climate-control and signaling applications for the NTS01/NTS10 series include:
- Electrical enclosures and distribution panels
- គណៈរដ្ឋមន្ត្រីគ្រប់គ្រងឧស្សាហកម្ម
- Panel heaters and anti-condensation systems
- ម៉ាស៊ីនត្រជាក់ត្រង និងម៉ាស៊ីនត្រជាក់
- Cooling devices for cabinet climate control
- Warning lights and alarm circuits
ហេតុអ្វីបានជាជ្រើសរើស VIOX NTS01/NTS10 Thermostats
The NTS01/NTS10 series gives panel builders, OEMs, and distributors a clear choice between heating and cooling control in the same compact DIN rail format. The two contact versions simplify model selection while supporting common enclosure climate-control and signaling tasks.
- ការជ្រើសរើសម៉ូដែលច្បាស់លាស់សម្រាប់ការគ្រប់គ្រងកំដៅ ឬត្រជាក់
- Compact housing for space-conscious panel layouts
- Straightforward 35mm DIN rail installation
- One thermostat family for climate-control and signaling applications
- សមស្របសម្រាប់ OEM អ្នកចែកចាយ និងការទិញគម្រោង
សំណួរគេសួរញឹកញាប់
តើអ្វីជាភាពខុសគ្នារវាង NTS01 និង NTS10?
NTS01-60 is an SPST-NC normally closed thermostat for heater and dehumidification control. NTS10-60 is an SPST-NO normally open thermostat for fan, cooling, warning-light, and alarm control.
តើជួរកំណត់សីតុណ្ហភាពគឺជាអ្វី?
Both models cover an adjustable setting range from 0 to +60°C.
តើឧបករណ៍កម្តៅត្រូវបានម៉ោនយ៉ាងដូចម្តេច?
The thermostat mounts on a standard 35mm DIN rail according to EN 60715.
តើបន្ទុកអ្វីខ្លះដែលឧបករណ៍កម្តៅនេះអាចប្តូរបាន?
The available product data lists 10(2)A at 250VAC, 15(2)A at 120VAC, and 30W at DC24V to 72V.
តើឧបករណ៍កម្តៅនេះត្រូវបានប្រើប្រាស់ជាទូទៅនៅឯណា?
Typical applications include electrical enclosures, control cabinets, panel heaters, filter fans, cooling devices, warning lights, and alarm systems.