Tổng quan
VOPV-30 Holder The VOPV-30 1000VDC 10×38mm heighten PV Fuse Holder is designed to fit 1000VDC PV Fuse, which can provide fast-acting protection under overload current conditions associated with Photovoltaic (PV) systems. The total height of the product has been increased from the original 61.5±0.5mm to 70±0.5mm, which can better match the matching circuit breakers and surge protectors, and unify the height of all accessories in the combiner box and other equipment to a horizontal plane, not only It increases safe operation and improves the aesthetics. VOPV-30 1000VDC 10×38mm heighten PV Fuse Holder is also available in 1, 2, 3 and 4-pole configurations.
Đặc trưng
- IEC60269-6
- Heighten version
- VOPV-30 1000VDC 10×38mm Fuse Link recommended
- 1000VDC Photovoltaic (PV) system available
- 30A ampere ratings
- Available in 1, 2, 3 and 4-pole configurations
- Meets IEC and UL standards for global acceptance
- Flame retardant shell with V0 standard
Thông số kỹ thuật
VOPV-30 Technical Specifications
| Tham số | Đặc điểm kỹ thuật |
|---|---|
| Mẫu VIOX | VOPV-30 |
| Danh mục sản phẩm | Solar PV Protection Fuse |
| Điện áp định mức | 1000VDC |
| Bình Hiện Tại | See Spec Table |
| Breaking / Performance | Khả năng phá vỡ cao |
| Tiêu chuẩn tuân thủ | IEC60269-6 / UL4248-19 |
Selection & Installation Notes
- Verify system maximum voltage (1000VDC) and prospective short-circuit fault current before selecting the fuse link or holder rating.
- Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
- Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
- Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.
Câu hỏi thường gặp
What voltage and current ratings does the VIOX VOPV-30 1000VDC 10×38mm Heighten PV Fuse Holder support?
This VIOX VOPV-30 series is rated for 1000VDC with a current rating of See Spec Table and High Breaking Capacity breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.
Which international standards apply to VIOX VOPV-30 1000VDC 10×38mm Heighten PV Fuse Holder?
The VOPV-30 series is designed and verified to IEC60269-6 / UL4248-19 requirements for safe overcurrent and short-circuit protection.
Where is the VIOX VOPV-30 1000VDC 10×38mm Heighten PV Fuse Holder typically installed?
It is engineered for solar pv protection fuse circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.
Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?
Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.