The VAF1-40 is an arc fault detection device combining arc-fault detection with Type A residual-current, overload and short-circuit protection. Designed for AC 50 Hz final circuits, it has a rated voltage of 240 V AC and is available in rated currents from 6 A to 40 A. The 1P+N device offers B or C overcurrent tripping characteristics and 10 mA or 30 mA residual-current sensitivities. It is intended for residential and commercial electrical installations requiring combined protection against electrical fires, electric shock and overcurrent faults.
Jellemzők
- Integrated arc-fault, Type A residual-current, overload and short-circuit protection.
- Compliant with IEC/EN 61009-1 and IEC/EN 62606.
- Rated-current options from 6 A to 40 A.
- B and C overcurrent tripping characteristics.
- 10 mA and 30 mA residual-current sensitivities.
- Load-disconnect contact with 6 kA rated short-circuit current.
Műszaki adatok
Elektromos adatok
| Paraméter | Specifikáció |
|---|---|
| Névleges áram (In) | 6, 10, 13, 16, 20, 25, 32, 40 A |
| Névleges feszültség (Ue) | 240 V AC |
| Működési gyakoriság | 50 Hz |
| Minimum test-circuit operating voltage | 196 V |
| Maximum test-circuit operating voltage | 253 V |
| Névleges szigetelési feszültség (Ui) | 250 V |
| Névleges impulzusállási feszültség (Uimp) | 4 kV |
| Rated short-circuit current | 6 kA |
| Maximum total rated switching capacity | 6 kA |
| Surge-current withstand strength | 0.25 kA |
| Power loss per current path | 3 W |
| Short-circuit back-up fuse (SCPD) | 100 A |
| Back-up fuse type | gG |
| Túlfeszültség kategória | III |
Védelmi adatok
| Paraméter | Specifikáció |
|---|---|
| Product configuration | AFDD with integrated Type A residual-current, overload and short-circuit protection |
| Pólusok száma | 1P+N |
| Maradékáram típusa | A típus |
| Névleges maradékáram (IΔn) | 10, 30 mA |
| Overcurrent tripping characteristic | B, C |
| Load-circuit specification | Load-disconnect contact |
Telepítési adatok
| Paraméter | Specifikáció |
|---|---|
| Terminál típusa | Screw-type terminals; top or bottom connection on the load circuit |
| Neutral conductor position | Left or right |
| Maximum connected cable length | 70 m between the distribution board and the furthest socket outlet |
| Terminal clamping capacity | 1-25 mm² |
| Kapocs meghúzási nyomatéka | 2-2.4 N·m |
Standards Data
| Paraméter | Specifikáció |
|---|---|
| Alkalmazandó szabványok | IEC/EN 61009-1; IEC/EN 62606 |
Kiválasztási útmutató
| Kódpozíció | Jelentése | Catalog reference |
|---|---|---|
| V | VIOX vállalati azonosító | V |
| AF | Arc-fault protection product family | AF |
| 1 | Tervezési sorozatszám | 1 |
| 40 | Maximum frame current | 40 |
| C16 | C tripping characteristic and rated current | 16 A |
| A30 | A típusú áram-védőkapcsolós (RCD) védelem | 30 mA |
Névleges áram
Select a listed rating from 6 A to 40 A to match the final-circuit rating.
Kioldási karakterisztika
Select a B or C overcurrent tripping characteristic according to the circuit requirements.
Residual Sensitivity
Select a Type A residual operating-current sensitivity of 10 mA or 30 mA.
Alkalmazások
- Residential final circuits.
- Commercial final circuits.
- Circuits requiring arc-fault and electrical-fire protection.
- Circuits requiring combined residual-current and overcurrent protection.
Telepítés
- Use screw-type terminals with top or bottom connection on the load circuit.
- Confirm whether the selected configuration places the neutral conductor on the left or right.
- Use conductors within the listed terminal clamping capacity of 1-25 mm².
- Apply the listed terminal tightening torque of 2-2.4 N·m.
- Keep the connected cable length within 70 m between the distribution board and the furthest socket outlet.
- Use the listed 100 A gG short-circuit back-up fuse.
Letöltések
GYIK
Milyen védelmi funkciók vannak integrálva a VAF1-40 készülékbe?
Egyesíti az ívhiba-érzékelést az A típusú maradékáram-, túlterhelés- és rövidzárlat-védelemmel.
Milyen névleges áramerősségek és kioldási karakterisztikák érhetők el?
A katalógus 6, 10, 13, 16, 20, 25, 32 és 40 A névleges értékeket sorol fel, B vagy C túláram-kioldási karakterisztikával.
Milyen maradékáram-érzékenységek érhetők el?
A VAF1-40 A típusú maradékáram-védelemmel rendelkezik, 10 mA vagy 30 mA érzékenységgel.
Mekkora a VAF1-40 névleges rövidzárlati árama?
A névleges rövidzárlati áram 6 kA.
Mi a maximális csatlakoztatott kábelhossz?
A katalógus legfeljebb 70 m távolságot ír elő az elosztótábla és a legtávolabbi dugaszolóaljzat között.
Mely szabványok vannak felsorolva a VAF1-40 típushoz?
Az alkalmazandó szabványok az IEC/EN 61009-1 és az IEC/EN 62606.