The VIOX VAF1-40 arc fault detection device combines arc-fault detection with Type A residual-current, overload and short-circuit protection. Designed for 240 V AC, 50 Hz final circuits, it is available in 6-40 A ratings, B or C tripping characteristics and 10 or 30 mA residual-current sensitivities. Its 1P+N configuration supports residential and commercial electrical installations.

Névleges áram
6-40 A
Maradékáram
10, 30 mA
Kioldási karakterisztika
B, C
Rövidzárlati áram
6 kA

Áttekintés

The VAF1-40 is an arc fault detection device combining arc-fault detection with Type A residual-current, overload and short-circuit protection. Designed for AC 50 Hz final circuits, it has a rated voltage of 240 V AC and is available in rated currents from 6 A to 40 A. The 1P+N device offers B or C overcurrent tripping characteristics and 10 mA or 30 mA residual-current sensitivities. It is intended for residential and commercial electrical installations requiring combined protection against electrical fires, electric shock and overcurrent faults.

Jellemzők

  • Integrated arc-fault, Type A residual-current, overload and short-circuit protection.
  • Compliant with IEC/EN 61009-1 and IEC/EN 62606.
  • Rated-current options from 6 A to 40 A.
  • B and C overcurrent tripping characteristics.
  • 10 mA and 30 mA residual-current sensitivities.
  • Load-disconnect contact with 6 kA rated short-circuit current.

Műszaki adatok

Elektromos adatok

Paraméter Specifikáció
Névleges áram (In) 6, 10, 13, 16, 20, 25, 32, 40 A
Névleges feszültség (Ue) 240 V AC
Működési gyakoriság 50 Hz
Minimum test-circuit operating voltage 196 V
Maximum test-circuit operating voltage 253 V
Névleges szigetelési feszültség (Ui) 250 V
Névleges impulzusállási feszültség (Uimp) 4 kV
Rated short-circuit current 6 kA
Maximum total rated switching capacity 6 kA
Surge-current withstand strength 0.25 kA
Power loss per current path 3 W
Short-circuit back-up fuse (SCPD) 100 A
Back-up fuse type gG
Túlfeszültség kategória III

Védelmi adatok

Paraméter Specifikáció
Product configuration AFDD with integrated Type A residual-current, overload and short-circuit protection
Pólusok száma 1P+N
Maradékáram típusa A típus
Névleges maradékáram (IΔn) 10, 30 mA
Overcurrent tripping characteristic B, C
Load-circuit specification Load-disconnect contact

Telepítési adatok

Paraméter Specifikáció
Terminál típusa Screw-type terminals; top or bottom connection on the load circuit
Neutral conductor position Left or right
Maximum connected cable length 70 m between the distribution board and the furthest socket outlet
Terminal clamping capacity 1-25 mm²
Kapocs meghúzási nyomatéka 2-2.4 N·m

Standards Data

Paraméter Specifikáció
Alkalmazandó szabványok IEC/EN 61009-1; IEC/EN 62606

Kiválasztási útmutató

Kódpozíció Jelentése Catalog reference
V VIOX vállalati azonosító V
AF Arc-fault protection product family AF
1 Tervezési sorozatszám 1
40 Maximum frame current 40
C16 C tripping characteristic and rated current 16 A
A30 A típusú áram-védőkapcsolós (RCD) védelem 30 mA

Névleges áram

Select a listed rating from 6 A to 40 A to match the final-circuit rating.

Kioldási karakterisztika

Select a B or C overcurrent tripping characteristic according to the circuit requirements.

Residual Sensitivity

Select a Type A residual operating-current sensitivity of 10 mA or 30 mA.

Alkalmazások

  • Residential final circuits.
  • Commercial final circuits.
  • Circuits requiring arc-fault and electrical-fire protection.
  • Circuits requiring combined residual-current and overcurrent protection.

Telepítés

  • Use screw-type terminals with top or bottom connection on the load circuit.
  • Confirm whether the selected configuration places the neutral conductor on the left or right.
  • Use conductors within the listed terminal clamping capacity of 1-25 mm².
  • Apply the listed terminal tightening torque of 2-2.4 N·m.
  • Keep the connected cable length within 70 m between the distribution board and the furthest socket outlet.
  • Use the listed 100 A gG short-circuit back-up fuse.

GYIK

Milyen védelmi funkciók vannak integrálva a VAF1-40 készülékbe?

Egyesíti az ívhiba-érzékelést az A típusú maradékáram-, túlterhelés- és rövidzárlat-védelemmel.

Milyen névleges áramerősségek és kioldási karakterisztikák érhetők el?

A katalógus 6, 10, 13, 16, 20, 25, 32 és 40 A névleges értékeket sorol fel, B vagy C túláram-kioldási karakterisztikával.

Milyen maradékáram-érzékenységek érhetők el?

A VAF1-40 A típusú maradékáram-védelemmel rendelkezik, 10 mA vagy 30 mA érzékenységgel.

Mekkora a VAF1-40 névleges rövidzárlati árama?

A névleges rövidzárlati áram 6 kA.

Mi a maximális csatlakoztatott kábelhossz?

A katalógus legfeljebb 70 m távolságot ír elő az elosztótábla és a legtávolabbi dugaszolóaljzat között.

Mely szabványok vannak felsorolva a VAF1-40 típushoz?

Az alkalmazandó szabványok az IEC/EN 61009-1 és az IEC/EN 62606.

Termékajánlatot kérne?
Építsük fel együtt.

Küldje el nekünk a termékmodelljét, a műszaki jellemzőket, a mennyiséget és az OEM-követelményeket. Csapatunk áttekinti az alkalmazást, és egy munkanapon belül válaszol.

Kérjen Árajánlatot