VIOX Electric
Language

อุปกรณ์สวิตช์และอุปกรณ์ตัดตอน (Switching & Isolation)

สวิตช์โรตารี่แคมรุ่น LW26 ขนาด 10A–315A

  • Rotary cam switch for circuit changeover, motor control, master control and measurement circuits
  • Rated current range: 10A to 315A
  • Rated operational voltage: up to 440V AC or 240V DC
  • Maintained, spring-return and combined operating mechanisms
  • Configurable switching angles, positions and contact sections
กระแสไฟฟ้าที่ได้รับการจัดอันดับ
10A–315A
Voltage
≤440V AC / ≤240V DC
มุมการสับเปลี่ยน (Switching Angles)
30° / 45° / 60° / 90°
โหมดการทำงาน
แบบคงตำแหน่ง (Maintained) / แบบสปริงดีดกลับ (Spring Return)

Contact-program selection and OEM support available

ภาพรวมผลิตภัณฑ์

The VIOX LW26 rotary cam switch provides manual switching for control panels, industrial machinery, electrical distribution equipment, and measurement circuits. Its modular cam-and-contact construction can be configured for circuit changeover, motor control, master control, instrument selection, and other defined switching sequences.

The range covers conventional thermal currents from 10A to 315A and operating voltages up to 440V AC or 240V DC. Maintained, spring-return, and combined operating mechanisms are available with application-specific positions, switching angles, contact sections, and handle markings.

ตัวเลือกโมเดล

Current Frame Common Model Designations Ith Ui Reference Ue
10เอ LW26-10, LW26-10G, LW26-10X 10เอ 660/690V 240/440V AC
20เอ LW26-20, LW26-20X, LW26-20C 20เอ 660V 24/110/240/440V, configuration dependent
25ก. LW26-25 25ก. 660V 24/110/240/440V, configuration dependent
32เอ LW26-32, LW26-32F 32เอ 660V 240/440V AC
40เอ LW26-40, LW26-40F 40เอ 660V 240/440V AC
63ก LW26-63, LW26-63F 63ก 660V 240/440V AC
125เอ LW26-125 125เอ 660V 240/440V AC
160A LW26-160 160A 660V 240/440V AC
250เอ LW26-250 250เอ 660V 240/440V AC
315A LW26-315 315A 660V 240/440V AC

คุณสมบัติหลัก

  • Wide 10A to 315A current range for control and main-circuit applications
  • Suitable for AC circuits up to 440V and DC circuits up to 240V
  • Maintained, spring-return, and combined operating mechanisms
  • Selectable 30°, 45°, 60°, and 90° switching angles
  • Modular contact sections for application-specific switching programs
  • Panel-mounted construction for control cabinets and machine interfaces
  • Configurable poles, positions, handles, markings, and contact diagrams

ข้อมูลจำเพาะทางเทคนิค

พารามิเตอร์ Specification
ประเภทผลิตภัณฑ์ Panel-mounted rotary cam switch
Conventional thermal current (Ith) 10A, 20A, 25A, 32A, 40A, 63A, 125A, 160A, 250A, or 315A
แรงดันไฟฟ้าใช้งานที่กำหนด (Ue) Up to 440V AC; up to 240V DC
แรงดันฉนวนที่กำหนด (Ui) 660V for most frames; 660/690V shown for LW26-10
Operating mechanisms Maintained, spring return, or maintained/spring-return combination
Standard switching angles 30°, 45°, 60°, or 90°, depending on the contact program
ความทนทานทางกล 0.3 × 106 การดำเนินงาน
Electrical endurance 0.1 × 106 การดำเนินงาน
Reference operating frequency 120 operations per hour
Installation plate thickness 1–3mm in the supplied installation reference

Utilization-Category Reference Current

These values are transcribed from the supplied technical reference. A dash means that the reference did not state a value for that combination.

กรอบรูป AC-21A / AC-22A AC-23A ซี-3 เอซี-4
LW26-10 10เอ 7.5A 5.5A 1.75A
LW26-20 20เอ 15ก. 11A 3.5A
LW26-25 25ก. 22ก 15ก. 6.5 แอมป์
LW26-32 32เอ 30เอ 22ก 11A
LW26-40 37A 30เอ
LW26-63 63ก 57ก 36A 15ก.
LW26-125 100เอ 90เอ 75เอ 30เอ
LW26-160 150เอ 135A 95A 55A
LW26-250 200เอ
LW26-315 315A 265A 110A 95A

Operating Mode and Selection

Select the current frame together with the required positions, switching angle, contact program, and load category. The Ith marking alone is not sufficient for motor or inductive-load selection.

Maintained Operation

The handle remains in the selected position until it is turned again. This arrangement is used for source, instrument, speed, and other stable selection commands.

Spring-Return Operation

The handle returns automatically when released. It is suitable for momentary commands such as start, jog, or reset.

Combined Operation

Maintained and spring-return positions can be combined where one switching program requires both stable and momentary commands.

Positioning-type switches may use 1–12 contact sections; the supplied reference limits frames rated 63A and above to eight sections. Spring-return configurations normally use 1–3 sections, while the LW26-20 reference allows up to eight. Direct motor-control arrangements commonly use 1–6 sections.

Information Required for Selection

  • Conventional thermal current and operating voltage
  • Load type or utilization category
  • Number of poles and contact sections
  • Required handle positions and switching angle
  • Maintained, spring-return, or combined operation
  • Contact sequence, truth table, or wiring diagram
  • Panel size, handle style, marking, color, quantity, and destination market

ขนาด

The supplied installation reference shows a 1–3mm panel thickness. The LW26-10 drawing uses a central Ø20mm opening with two Ø4.5mm fixing holes on a 30 ±0.20mm spacing reference. Dimensions for LW26-20 through LW26-315 vary with the current frame and operator assembly; confirm the exact drawing before machining the panel.

LW26 rotary cam switch dimensions and panel cutout drawing

แอปพลิเคชั่น

Typical switching, control, and instrument-selection applications for the LW26 include:

  • Main and auxiliary circuit changeover
  • Direct control of three-phase asynchronous motors
  • Forward/reverse, star-delta, and multi-speed motor circuits
  • Ammeter and voltmeter selector switches
  • Master control and command switching
  • Test benches, welding equipment, and industrial machinery
  • Control panels, distribution boards, and OEM equipment

Operating and Installation Conditions

  • Ambient temperature: −25°C to +40°C
  • Average temperature over 24 hours: not more than +25°C
  • Maximum installation altitude: 2000m
  • Relative humidity: up to 50% at +40°C; higher humidity may be permissible at lower temperatures
  • Reference humidity condition: up to 90% at +20°C, with precautions against condensation
  • Installation environment: pollution degree 3
  • Install according to the wiring program, panel cut-out, and instructions for the selected model

Standards Reference

The supplied technical material references GB/T 14048.3, GB/T 14048.5, and EN 60947-5-1. These are standards references, not a blanket certification claim. Applicable conformity, test documents, and destination-market certification must be confirmed for the exact current frame, contact program, and application before ordering.

คำถามที่พบบ่อย

What is an LW26 rotary cam switch used for?

It manually changes a defined group of contacts as the handle moves between positions. Common uses include circuit changeover, motor commands, phase or instrument selection, and master control.

Can one LW26 switch cover several switching positions?

Yes. The cam mechanism can be configured for multiple positions and contact sections. The available sequence depends on the current frame, operating angle, and required wiring program.

Should an LW26 be selected only by its Ith rating?

No. Check the utilization category, operating voltage, motor duty, number of poles, and switching sequence. Motor loads can require a lower operational current than the thermal-current marking.

ข้อมูลใดบ้างที่จำเป็นสำหรับการกำหนดโปรแกรมหน้าสัมผัสแบบพิเศษ

Provide the required positions, switching angle, maintained or spring-return action, number of poles, and a contact truth table or wiring diagram.

Which documents are available for my market?

Documentation depends on the exact model and destination market. Confirm the required standard, test report, or certification with VIOX before ordering.

Need an LW26 Rotary Cam Switch Quote?
Let’s Confirm the Contact Program.

Send us the required current, voltage, load type, handle positions, switching angle, contact diagram, quantity, and destination market. Our team will review the configuration and respond within one business day.

ขอใบเสนอราคา