VIOX VSP1-C40PV/3(S) 600V Pluggable Multi-Pole SPD

VIOX VSP1-C40PV/3(S) 600V Pluggable Multi-Pole SPD offers robust surge protection for photovoltaic systems and DC applications. This Class II/Type 2 device safeguards (DC+) – PE and (DC-) – PE modes with 20kA nominal and 40kA maximum discharge current. Featuring high-energy MOV elements, it operates at 600V DC with < 25ns response time. The pluggable design ensures easy installation on 35mm DIN rails. Compliant with IEC 61643-31:2018 and EN 50539-11:2013+A1:2014, it provides a voltage protection level of 2.2kV. With IP20 protection, thermal safeguards, and optional remote contacts, this versatile SPD combines reliability and performance for enhanced power system protection in demanding multi-pole DC and photovoltaic applications.

ສົ່ງຄວາມຕ້ອງການຂອງທ່ານ, ພວກເຮົາຈະອ້າງອີງໃຫ້ທ່ານພາຍໃນ 12 ຊົ່ວໂມງ

VIOX VSP1-C40PV/3(S) 600V Pluggable Multi-Pole SPD

ພາບລວມ

The VIOX VSP1-C40PV/3(S) 600V is a high-performance Pluggable Multi-Pole Surge Protective Device (SPD) designed for use in sub-distribution boards. This versatile device offers robust protection for (DC+) – PE and (DC-) – PE modes, making it an ideal solution for photovoltaic systems and other DC applications.

ຄຸນນະສົມບັດທີ່ສໍາຄັນ

  • Class II, Type 2 device
  • ສະຖານທີ່ນຳໃຊ້: ກະດານຍ່ອຍຍ່ອຍ
  • ຮູບແບບການປົກປ້ອງ: (DC+) – PE, (DC-) – PE
  • Surge Ratings: ໃນ = 20 kA (8/20 μs)
  • IEC/EN/UL Category: Class II / Type 2
  • ອົງປະກອບປ້ອງກັນ: MOV ພະລັງງານສູງ
  • ທີ່ຢູ່ອາໄສ: ການອອກແບບ pluggable
  • ການປະຕິບັດຕາມ: IEC 61643-31:2018, EN 50539-11:2013+A1:2014

ຂໍ້ມູນຈໍາເພາະ

IEC ໄຟຟ້າ 600
Nominal DC Voltage 600V
ແຮງດັນເຮັດວຽກຕໍ່ເນື່ອງສູງສຸດ (DC) 600V
ປັດ​ຈຸ​ບັນ​ການ​ປ່ອຍ​ຕົວ​ຊື່ (8/20 μs​) 20 kA
ກະແສໄຫຼສູງສຸດ (8/20 μs) 40 kA
Impulse Discharge Current (10/350 μs) 6.25kA
ລະດັບການປ້ອງກັນແຮງດັນ 2.2kV
ເວລາຕອບສະຫນອງ < 25 ນ
ຟິວສຳຮອງ (ສູງສຸດ) 125 A gL / gG
ການຈັດອັນດັບກະແສໄຟຟ້າສັ້ນ (AC) 25 kA / 50 kA

ຂໍ້ມູນສະເພາະດ້ານກົນຈັກ ແລະສິ່ງແວດລ້ອມ

  • ຊ່ວງອຸນຫະພູມໃຊ້ງານ: -40°F ຫາ +158°F [-40°C ຫາ +70°C]
  • ຄວາມຊຸ່ມຊື້ນທີ່ອະນຸຍາດ: 5%…95%
  • ຄວາມກົດດັນ ແລະ ລະດັບຄວາມສູງຂອງອາກາດ: 80k Pa … 106k Pa / -500 m….2000 m.
  • Terminal Screw Torque: 39.9 lbf.in [4.5 Nm]
  • Conductor Cross Section (max): 2 AWG (Solid, Stranded) / 4 AWG (ຢືດຢຸ່ນ)
  • 35 mm² (ແຂງ, Stranded) / 25 mm² (ຍືດຫຍຸ່ນ)
  • ການຕິດຕັ້ງ: 35 mm DIN Rail, EN 60715
  • ລະດັບການປົກປ້ອງ: IP 20 (ໃນຕົວ)
  • ວັດສະດຸທີ່ຢູ່ອາໄສ: Thermoplastic: Extinguishing Degree UL 94 V-0
  • ການປ້ອງກັນຄວາມຮ້ອນ: ແມ່ນແລ້ວ
  • ລັດປະຕິບັດງານ / ຕົວຊີ້ວັດຄວາມຜິດ: ສີຂຽວ ok / ສີແດງຜິດປົກກະຕິ

ຄຸນສົມບັດເພີ່ມເຕີມ

  • ຕິດຕໍ່ທາງໄກ (RC): ທາງເລືອກ
  • RC Switching Capacity: AC: 250V / 0.5 A; DC: 250V / 0.1 A;125V / 0.2 A;75V / 0.5 A