α ααααΎααα ααα αααΆαα’ααααΆααααΉα (Neutral Bar) αααααΉααααΆαααΈ (Grounding Bar)

αα½α αααΆαα’ααααΆααααΉα αααααΆααααααα’ααααΆααααΉα αα·αααΆααααααΆαααα»αα αααααααα‘αααα ααααααααααααααααα·αα A αααΆαααΈ (Grounding bar), αααααααΌαααΆαααα α αααααααΆ αααΆαααΈ (Ground bar), αααΆααααααΈ, α¬ αααΆα PE, αααααΆααααααααΆαααΆαααΈ αα·αααΆααααααΆαααα»αα αααααααααα»αα’αα‘α»ααααααΆαααααΆαααΆαααΌα ααΆαααα»αααααα.
αα αααα»αα§αααααααααΆαααααα ααααααΊα (Neutral) αα·αααααααΈ (Ground) α’αΆα ααααΌαααΆαααααΆααααααΆαα α ααα»α ααααΆαααααααΆααααααα α αααααααααα ααα αΆαααααΎααα (Subpanels) α¬ααΌα ααα αΆαααααΎααα αααααααΆαααααα αααΆαααΊαααΆααααααΆααααΌααααααΆαα»αα±ααααΆα ααααα‘ααααΈαααααααΌ αααααααααΆαααΈααααΌαααααΆαααα ααΉααααααααΌα.
α αααΆαααα½ααααααΆαααΆααα·αα±ααα ααααααΊαααααααΆα αΌαααααααΆααααααΌαααΆαααΆαααααααΈ αααααααα αααααααααααΆα αααααΆαααΆααααα ααααΏαααααα»ααααααΈα (DIN rail) α¬ααα»αα§αααααα‘αΎαα.
ααΆααααααααααααΆααααΆαααΊα αα·ααααΆαααΈαααα»αααΆααΆααααα½α
| αααααα | ααΆαα’ααααΆααααΉα | αααΆαααΈ / αααΆαααααααΈ / αααΆα PE |
|---|---|---|
| αα»αααΆαα αααα | αααααΌααααα»αααααααΊα αα·ααααααααΆααααΌααααα‘ααααα ααααααααααΆ | αααααΌααααα»αααααααΆαααΆαααΈ αα·ααααααααΆααααΌαααΆαααΆααα αααααΆαααΆαααααα αααα |
| α ααααααααααΆ | ααΆα/α αΆα ααΆα’αΆα αααα»αα αααααααα‘ααααααααα»ααααα»αα’αα‘α»ααααααααα·ααααα·ααΆαααααααΆ | αα ααΆαα·ααα½ααααα»αα ααααα’αααα·αααΈααααααΆα‘αΎα |
| αα½ααΆααΈαααα»αααααΈααΆαααα α»ααααα | ααααααααααααααααααα»αα αααααααααΆαααΆαα α»αααΈ ααααααα»ααααααααααΊα (Neutral) ααααΌαααΆαααααΎααααΆαα | αα½ααααααΎαααααΌαα ααααααα α»αααααΆαααααα·αααααΆα ααΎααααΈα±ααααααααααααΆαααΆαα’αΆα ααααΎαααΆαααΆα |
| ααΆαααααΎααΆαααααΆααααααααΆα IEC | αααΆαααααααΊα (N bar) | αααΆαααααααΈ (PE bar α¬ earth bar) |
| ααΆαααααΎααΆαααααΆααααααααΆαα’αΆαααα·αααΆαααΎα | αααΆαααααΆαααααααΆααααααα’ααααΆααααΉα (Neutral bus bar) | αααΆαααααΆαααααααΆααααααααΈ α¬αααΆααααααΆααααααααΈααααα§ααααα (Ground bar or equipment grounding bar) |
| ααΆαααααΆα αα ααααα’αααα·αααΈααΆααΌαα (Typical isolation) | ααΆαααααΆα αα ααααΈαααααααΌαααα»ααααααα ααα αΆαα ααααααΆαααααα (Isolated from enclosure in downstream panels) | ααΆααααααΆαααα ααΉααααααααΌααααααα»αααααΈα αΆαααΆα α (Bonded to the metal enclosure where required) |
| αααααααααα αα αΆαα ααααααΆααΌαα (Typical conductor color) | αααα α¬ααααααααα αααα»αααααααααα’αΆαααα·αααΆαααΎα; αααααα αααα»ααααααααα IEC ααΆα αααΎα | αααααα/ααααααα αααα»αα’αΆαααα·αααΆαααΎα; αααααααααΆαααΏα αααα»ααααααααα IEC |
| αααααααααααα·ααααΈααΈα ααα»α αααααΆαα (Terminal) | ααΆααΌαα ααααα’ααααΆααααΉα (Neutral) αα½ααααααααα»ααα½αα ααα»α αααααΆαα αααααΆααααααΈααΆαααΆαααααααΌααααΎα | ααααααΆαααΆα (PE) α αααΎαααααα’αΆα ααααΌαααΆαα’αα»ααααΆα αα»αααααΆαααααΆα (Bar) αα·αα ααα»α αααααΆααα’αα»ααααΆαα±ααααααΎααΌα αααα |
| α αΆαα·αααααααΆαααααΎααααΆαααα»α | α ααααα’ααααΆααααΉαα’αΆα ααααΎα±αααααααααΆαααΆαααΆαα ααααα’αααα·αααΈ ααααα·αααΎααΆααααααΆαααα·αααααΉαααααΌα | αααααααα ααααααΆααααααΆαα’αΆα ααΆαα ααααα’αααα·αααΈ ααααα·αααΎααααΎααΆααααΌααααααΆααααααα’ααααΆααααΉα |
αααααΆααααα·ααααααΌα ααα αΆαααααΎα (Distribution-box) αααα VIOX αααα’ααα ααα αΆα αα·αααΆαααααΆαααααΎαααΎα ααααααααΈααααααα MCB, RCBO, ααΆαααΆα (Busbars), αααΆαα’ααααΆααααΉα (Neutral bars), αααΆαααΈ (Earth bars) αα·α SPD ααααΌαααΆαααα‘αΎααα½αααααΆαα αααα»αααΌααααΎααααΌαα»α.
ααΎα’αααΈαα ααΆ Neutral Bar?
αα½α αααΆαα’ααααΆααααΉα ααΊααΆαααααααααΆααα ααααα’αααα·αααΈ α¬αααα»αααααααααΆααααααΆαααααα Neutral ααααααααΈααΆα αααΎαα αΌαααααΆα αα αααα»αααααααΈα ααααααααΆαα (AC) ααααΆααααΆααααα½α αααα Neutral ααΎααα½ααΆααΈαααααααααααΈααααααααΌαα αααααααα‘αααα ααααααα·αα αα αααα»αααααααααααΈααααΆααααΆα (Three-phase) α αααα Neutral α’αΆαααααααΎαα»αααααΆαααααααα»α αα·αααΆαα·ααΆα αΆαααΌαα·α ααα»αααααααα Neutral αα ααααΆαααααααααΆαα ααααα’αααα·αααΈα αΌαααααααΆαααα αααααααΎααααΆααα.
αα αααα»ααααααααααΌαααΆαααααΌα’αααα·αααΈ αα·αααααΆααα ααα αΆαααααΎαααΆααααααααΆα IEC, Neutral bar αααααααααΌαααΆαααΆαααααααααΆα
- α
- αααΆαααααααΊα (N bar)
- neutral busbar
- neutral terminal bar
- neutral link
Neutral bar αα·ααααααΆα ααα»α αααααΆααααααΆααααααααΈ (Grounding) α‘αΎαα ααΆααΊααΆααααααα½αααααααααΈαααααΆαα ααααα’αααα·αααΈα αΌαααααααΆααααΆααααααααΈα α ααα»ααΌα ααααα αΎαααΆαααΆαα»αααΆαααααΆααααααΆαααααα Neutral ααΆαααΆααααααΆααααααΆααα ααΆααααααΆαααααα Neutral αα·αΰΉΰΈΰΉΰΈα’αΆα αααααΆαα±ααααΆαααααα ααααΆαα ααα»ααα·ααααα·αααααα ααΆαααΌα ααΆαα§ααααα αα·αααααααΆαααααααααΆαααα»ααααα·ααΆααααααααααα.
ααΎα’αααΈαα ααΆ Grounding Bar α¬ Earth Bar?
αα½α αααΆαααΈ (Grounding bar) ααΊααΆαααααα αααααααααααΎαααααΆααααααΆααααααααΆαααΆαααΈ (Protective Earth)α αα αααα»αααΆααααααα IEC ααΆααααΌαααΆαααα α ααΆααΌαα ααΆ αααΆα PE α¬ αααΆααααααΈ. α αα αααα»αααΆαααααααα’αΆαααα·αααΆαααΎα ααΆα’αΆα ααααΌαααΆαααα α ααΆ αααΆαααΈ (Ground bar) α¬ αααααααααΆααααΈαααααΆααα§ααααα (equipment grounding bar).
αααααααααααααΆααΊααΎααααΈαα»ααααα·ααΆα αα·αααααααααΆααααΆααααα‘αααααα·αααααααα»αααααααΆαααααα αααααααααΆααααΈ (Grounding bar) ααααΆααα
- conductor ααΈααΆαααΆα
- conductor ααΈα§ααααα
- conductor bonding
- α ααα»α ααααΆαααααααα’ααααα (metallic enclosure bonding points)
- ααααααΈααααα§αααααααΆαααΆαααααα (SPD) ααααα·αααΎααΆα
- ααααΆαααΌ ααααααααααΆααααα‘αΎα α¬αααααααααααα’αΆα αααα ααααΆα ααΆαααΆααααααααααΆααα ααΆ
αααα»αα’αα‘α»ααααααΆαααΆαααααα αααα (Fault) ααααααααααΈ/PE αααααααΌαααααΌαααΆαααΆααααααΆαααΆααααααααΆαααΆα ααΎααααΈα±ααα§αααααααΆαααΆααααααααααα’αΆα ααααΎαααΆαααΆαα αα αααα»ααααααααααα·αααααααααΆααααααα ααααα αα·ααααααααΆααααααΆ "ααΆααααααΌαα αααααα αααα»αααΈ" αααααα ααααΌαααα ααααααααααααΌααααααα‘αααα ααααα α¬ααααααααααΆαααΆααα·αααααααααααααα·αααααΆα ααΎααααΈα±ααα§αααααααΆααα αααα (Breakers) α ααα»ααααΈα (Fuses) RCDs, RCBOs α¬α§αααααααΆαααΆαααααααααα’αΆα ααααΎαααααΆαααΆαααΆαααααααα»αα.
ααααα·αααΎαααΆαααΈ (ground bar) ααααΌαααααΆα αα ααααα’αααα·αααΈααΈααααααα‘αΎααααααΆαααααααααΆααααΆααααΆαα½α ααΌαααααΎααααΆααααααΏαααα·ααααΆααααααααΌαααΆααα ααΆα‘αΎααααααΆααααααααααααα ααααα»ααααααααααα VIOX ααααΈααΈ ααΎα’αααΈαα ααΆα§αααααα’ααΈααΌα‘αααααΆαααΈ (ground bar insulator kit) ααΊααΆα―αααΆααααααααΆααααααααααααααΆαααααααααααααααΏαααα·ααααΆααααα.
ααΆαααααααα NEC αααααΉα IECα Neutral, Ground, N αα·α PE
ααΈααααΆαααααααααααΆααααΎααααΆααααΆααΆαα»ααααααΆαααααΆααααααααα·ααα»ααααα·ααΆαααΌα ααααΆα ααΆαααααΎααααΆααααΆαααααΆαα‘αααααΆααααα·ααααααΈαα»αααΆαααααααΆ ααΊααΆαααααααΌαα ααααα α»ααααα»αααΆααα ααΆα.
| ααΆααα | ααΆαααααααα NEC / α’αΆαααα·αααΆαααΎα | ααΆαααααααα IEC / α’ααααααΆαα· | αα»αααΆα |
|---|---|---|---|
| ααΆαα’ααααΆααααΉα | αααΆαααααΆαααααααΆααααααα’ααααΆααααΉα (Neutral bus bar) | αααΆαααααααΊα (N bar) | αααα»αα αααααααα‘ααααααααΆαααααααααααααααα Neutral ααααΌαααΆαααααΎααααΆαα |
| αααΆαααΈ (Grounding bar) | αααΆαααΈ / αααΆαααΈαααααΆααα§ααααα (Ground bar / equipment grounding bar) | αααΆα PE / αααΆαααΈ (PE bar / earth bar) | αααααΆααααααααΆαααΆαααΈ αα·αααααΌαα ααααααα α»α (Connects protective earth conductors and fault-current paths) |
| ααααααΊα (Neutral conductor) | αααααααααααΆαααα ααΈ (Grounded conductor) | αααα N (N conductor) | ααααΌααααα‘ααααα ααααα’αααα·αααΈ (Current-carrying return path) |
| ααααααΈ (Ground conductor) | α§αααααα ααααααΈ | ααααααΆαααΆα PE (PE conductor) | ααααααααΌαα ααααααα α»αααΆαααΆα αααααΆααααααΆαα·αααΆαα ααααααααααΆαα |
| ααΆααααααΆαααααΆαααααα’ααααΆααααΉααα·αααααααΈ (Neutral-ground bond) | αααααααααΆαααα α¬αααααααααΆαααααααααα (Main bonding jumper or system bonding jumper) | ααΆααααααΆαα N-PE αα α ααα»α αααααααααααααΆαααααα | ααααααααααΆαααΆααα ααΆ αα·αααααΌαα ααααααα α»ααα α ααα»α αααα’αα»ααααΆα |
αααααα α α’αΆα ααααΆααααααΌααα ααΆαααααα ααα»αααααααααΆαααααΊαα ααααα αααα N αααα»αα αααααααα‘ααααααααΆα αααα PE ααΊααΆααααααΆαααΆαα αα½αααΆααααΌααααα·αααααΌαααΆαααΆααααα αΌαααααΆαααα αααααα‘αΎαα.
αααααα ααα αΆααα (Main Panel) αααααΉααααααα ααα αΆααα (Subpanel)α ααΎαααααΆααααααα Neutral αα·ααααα Ground ααααΌαααααΆααααααΆ?

α αααΆααααααΆαααααΆααααΊααΆα ααα»α αααααα α»ααααα»αααΆαααα‘αΎαααΆα αααΎααααααα αΆααααααΎαα.
α§αααααααααΆαααααα (Main Service Equipment)
αα αααα»αα§αααααααααΆαααααα α’αΆαααα·αααΆαααΎα αααα Neutral αα·ααααα Ground ααααα§αααααααααΌαααΆαααααΆααααααΆαα αααααα ααα»α ααααΆα αααααΆαααα α¬α ααα»α ααααΆααα§αααααααααΆαααααααααΆααααααα ααΆααααααΆααΆααααΌαααΆαααααΎα‘αΎααααααααΎ Main bonding jumper, ααΈαααααΆαα (bonding screw) α¬αααααααααΆααααααΆαα (bonding strap) αααααααΌαααΆαα’αα»ααααααααΆααα§ααααααααα.
ααΆαααααΆααααααααααΆαααααααααααααααααααΆαααΈ (grounded conductor system) αααααααααααα Ground ααααα§ααααα αααααααΆαααΆα αα·αααααααααα’αα‘α·α ααααΌαααΈ (grounding electrode system) ααααααΆαα αααΆααααα‘αΎααααααΆααααααΆαααααααα.
α ααα»α αααα’α·αααααααΆααααΊααΆ ααΆαααααΆαααααααααΌαααααααΎα‘αΎααα αααααα ααα»α αααααΆαααααα αα·ααααααααΎαα ααααααααΆαααααΆααααα½ααααααα.
αααααα ααα αΆαααΆααααα (Subpanels) αα·αααααΆααα ααα αΆαααΆααα (Distribution Boards) αα αααααααΆαααααα
αα αααα»ααααααα ααα αΆαααΆααααα α¬ααααΆααα ααα αΆαααΆααα αααΆαααααα’ααααΆααααΉα (Neutral bar) ααΆααααααΆααααΌααααααΆα±ααααΆα ααααα‘ααααΈαααα’ααααΌα α αααααααΆαααααααΈ (Grounding bar) ααααΌαααααΆαααα ααΉααααα’ααααΌα.
ααΆαααααααααααΆαααΆααα·αα±ααα ααααα’ααααΆααααΉαααααααΆα αΌαααΆαα
- conductor ααΈααΆαααΆα
- ααααααααααΆαααΆαααααααααΎα (Metal conduits)
- ααααααααααΆαααΆαααααααααΎα (Cable armor)
- αα½αααα’ααααΌ (Enclosure bodies)
- αααααα§ααααα (Equipment frames)
- ααααααααα DIN (DIN rails) αα·ααα ααΆααααααααααα‘αΎα (Mounting structures)
ααααα·αααΎααααα’ααααΆααααΉα (Neutral) αα·αααααααΈ (Ground) ααααΌαααΆαααααΆααααααΆααααααααα αααααααΆαααααααααααααααα αααααΆαααα‘αΎαααΉααααααΎαααααΌααααα‘ααααα ααααααααααααΆα α ααααααααα½ααααααα·ααα ααΎααααα’ααααΆααααΉαα’αΆα α αΌαααΆααααααααΌαααααααΈ αα·ααααααααα ααααααΆααααααΆαα.
ααααααααααααααααΎααααα‘ααααΈααααΆ (Separately Derived Systems)
αααααααααα αααΆαααΈαααααΎα αααααααα UPS αα·αααααααααα’αΆααααΊαααααα½αα ααα½αα’αΆα αααααΎαααΆααααααααααααααααΎααααα‘ααααΈααααΆ αααααΆαα αααΆααααααΆααααααααΈααααΆαααααα½αα αααααΆααααα ααααααα ααααΌαααααΆααααααααΈαααα α ααα»α ααααααααΌααααααΆααα ααΆαααααααα αα·αααααααΆααααααΆαααααααααα»αααααα.
ααααααααΆααααααααΆα IECα αααΆα N, αααΆα PE, αααααααα TN-S, TN-C-S, TT αα·α IT

ααΆαααα‘αΎαααΆααααααααΆα IEC ααααααα·ααΆααααΆα’αααΈαααΆαα’ααααΆααααΉα αα·ααααΆαααααααΈααΆααααααΆααααα αααααααααααααααΈα αααααΆαααΆααααααΆααααΆαα·ααααααααΆααα’ααααα·α B2B ααΌααΆαααα·ααααα α’αααααα·αααΌα’αααα·αααΈ αα·ααααα»αα αα»α OEM αααααααΆαααααααΌα’αααα·αααΈαααα½αα’αΆα ααααΌαααΆαααααααα½ααααααΆααααΈααααΆαααααααααααΆα.
| αααααααα | ααΆααααα ααααΆα Neutral / PE | α’αααααααααααΆαααααΆα N αα·ααααΆα PE |
|---|---|---|
| TN-S | ααααα’ααααΆααααΉα (Neutral) αα·αααααααΈααΆαααΆα (Protective earth) ααααΌααααααα ααααΈααααΆααααα½αααααααααααα‘αΎα | ααααΎαααΆα N αα·α PE ααΆα ααααα‘ααααΈααααΆ; αααΆα PE ααααΌαααααΆαααα ααΉααααααα αα αΆαα’αααα·αααΈαααααΆααααααΆα |
| TN-C | ααααα’ααααΆααααΉα αα·αααααααΈααΆαααΆαααααΌαααΆααααα αΌαααααΆααααα½αααααααααααΆαααααααααΆαααα PEN | αα·αααΆααααΆα N αα·α PE ααΆα ααααα‘αααα αααα»ααααααααααααα αΌαααααΆααααα; αααα PEN αα·αααααΌαααΆα αααΆα αααΆα α αΎαααΆαααααΎααααΆαα RCD ααΊααΆαααααα·α αα»αααααΆααααααααααααααΌαααΆαααααααααα ααΆααΆααααα αααΆα ααααα‘αααα αααααααΆαααααα (downstream) |
| TN-C-S | αααα PEN ααααΌαααΆαααααααα ααΆ N αα·α PE αα α ααα»α αααααΆαααααα | αααααΆααααΈααΆαααααα N αα·α PE ααααΌααααα ααΆα ααααα‘ααααΈααααΆαα αααααααΆαααααα (downstream) |
| TT | ααΆαααα‘αΎαααΆαα’αα‘α·α ααααΌαααΈ (earth electrode) ααααΆαααααα½α; ααααα’ααααΆααααΉαααααΌαααΆααααααααααααααα‘αα | αααΆα PE ααααΆαααα ααΉαααααααααααΈαααα»ααααα»α; ααΆαααΆαααΆαααα RCD ααΆααΏααααΆα ααα»α αααααΆαααααΆαααΆαααΆαααα α»ααααα |
| α’αΆα | ααααααααααααΌαααΆαααααΆα αα ααααΈααΈ α¬ααααΆαααα ααΈααΆααααααΆαααα (Impedance) | αααΆα PE αα ααααΆαααΆααααααΆαα ααΆααααα½ααα·αα·αααα’ααΈααΌα‘αα αα·αααααα·αααααα αααααΆαααα α»αααΎαααΈαα½α ααΉαααα₯αααα·αααααααΆααα ααΆ |
αααααΊααΆα ααα»α αααα’αααααα·αααααΆαααααααΆααΆααααααααΆα IEC ααααΌαααΆαααΆααααα»αααααααααα ααααααααααααΎαααΆααααααΆαααααααααα TN-S αα·αααααΆααααΆα’αΆα ααααΎααΆααααααααααααααααα·αααααΆαααααααααα TT α¬ IT ααααα ααααα·αααΎαα·αααΆααα·αα·αααα‘αΎααα·αααΎαα·ααΈααΆαααααααΆαααΆα αα»αααααΆααααα RCD/RCBO αααααα SPD αα·ααααααααααααα·ααααΆααααααΆααααααααααΎααααα»αααΌαααααΆα.
ααΆαααΆαα’αα»ααααααΆααααααα αα αααααααααα PEN ααααΌαααΆαααααααα ααΆαααα N αα·α PE ααΆα ααααα‘ααααΈααααΆ ααΆααααααΎααα αααααααΆαααααα (downstream) ααΉααα·ααααααΆ TN-C αα»αααααααα ααΆααΆαααααΆααα ααΆ TN-C-S α αΆααααΈα ααα»α ααααααααα α αΆααααΈα ααα»α ααααα αααα N αα·α PE ααααΌααααααααΆααΆααααααααΆα αααΈααααΆαα αααααααΆαααααα ααΎααααααααΆαααααααααααΆα ααααα‘ααααΆααααΆαα α¬αααααααααααα·αααα»αααΌαααααΆααααααΌαα±ααααΆαα ααα»α ααααΆααααααΈαααααΆαααααα.
αααααΆααααΆαααΆαααααααααααααααααΆααααα’ααααΆαααΆα (Enclosures) αααα’ααααα αα·αααααΆαααααααΆ ααΌαααΎα αααα’ααααΆαααΆαα§αααααα’αααα·αααΈ (Electrical Enclosure) αααααΉα αααα’ααα ααα αΆαααααΎα (Distribution Box) αααααΉα ααΆααΆαα ααα αΆαααααΎα (Distribution Board).
ααΌαα ααα»αααααΆαααααα N/PE ααΆαααΆααααααΆαααααααΆαα RCD, RCBO αα·α SPD
ααΆαααααααααα Neutral αα·α PE αα·ααααααααΆααααααΆαααα αΆααααΆααααααααααΆααααααΆααααααααααΎαααα»ααααααα ααα»ααααααΆααα₯αααα·αααααααααΆαααα ααΎα§αααααααΆαααΆα.
RCD αα·α RCBO
RCD α¬ RCBO ααααΎααΆαααααααααα αααααααα αΌαα αα αα·αα αΌααααα‘αααααα·αααΆαααααααααααααΆαα ααααα’αααα·αααΈα ααααα·αααΎα ααααααααα’ααααΆααααΉα (Neutral) ααα ααααΆαα αΌααα αααα»αααααααΆαααΆα (PE) αα αααααααΆααααααααα§ααααα ααΆαααΆαααααα ααααααααα αααα’αΆα ααΉααα·αααΆαααΆαααααΉαααααΌα α¬α’αΆα ααααΎα±ααα§αααααααΆααααααΎαααααα·αααΆαααααααα»αα.
ααααααααΆααΌαα ααααΆααααααααΆαααααα’ααααΆααααΉα (N) αα·αααααααΆαααΆα (PE) αα·αααααΉαααααΌααα½αααΆαα
- ααΆαααααΎααααΎαααααΆα
- RCBO ααΆααααααΎααααα ααααααααααα»ααα½αα ααα½αααααΎαααΆα
- ααΆαααα»αα’αααα·αααΈααααα·αααΆαααααΉααα»ααα ααΎαααααααα α
- ααΆαα ααααα’αααα·αααΈαααααΆααααΆααα ααΎααααααΆαααΆα (PE) αααα»αα’αα‘α»ααααααααα·ααααα·ααΆαααααααΆ
- ααΆααα·ααΆαααααα α»αααΆαααΆαααααΆα αααααΆαααααα’ααααΆααααΉα αα·αααααααΆαααΆαααααΌαααΆαααααΆαααααα αΌαααααΆ
ααααα·αααΎα’αααα’αΆαα’ααααααααα»αααααααααααααααα·αααααΆαααΆαααΆα ααααα»ααααααα VIOX ααααΈααΈ ααΆαα α»αααΈ (Grounding) αααααΉα GFCI αααααΉαααΆαααΆαααΆαααΆαααΎαα‘αΎαααα»αααααΆαα (Surge protection) ααΊααΆαααααααΆααααααααΉαααααΌαα.
SPDs
α§αααααααΆαααΆαααΆαααΎαα‘αΎαααα»α (Surge protective devices) α’αΆαααααααΎααααΌαααΆαααΆαααααΈ αα·αααααΆαααα ααΆαα N αα·α/α¬ PE α’αΆαααααααΎααααααΆαααΆαα ααααα·αααΎαααΆα PE αααα·ααα ααΈααΆαααα·αααα’ ααΆααααααΆαααα·αααααΉαααααΌα α¬ααΆαα‘αααΆαα½αααααααΊα (Neutral) αα·αααααΉαααααΌα ααααΌααααα ααα ααααααΎαα‘αΎαα’αΆα ααΉαααΆααααααα α¬αα·ααΆααααα»αααΆαααααααα»αααΆαα»αα.
αααααΆααααΆαααα‘αΎα SPD α αααΆααα’αα»ααααααΆαααααααααααααΆααααΆαααΌα ααΆααααααα
- αααααΆαα SPD αα ααΆααα ααα»α N αα·α PE αααααααΉαααααΌααααααΆααααααααααααΈ (Earthing system)
- αααααΆαααα PE α±ααααααΈ αα·αααααΆααααΆαααΆαααααΆαααααα’αααααα·α
- αααααΆαααΆααααααΎαααααα·α (Loops) ααααα·αα αΆαααΆα α
- αα»αααααΎαααΆαααΊα (Neutral bar) αααα½αα±αααααΆα PE
- αααααααααΆααααααααΆαααΆα N-PE αα ααααααααααααααΌαα±ααααΆα
αααααΆααα αΆαα·αααααααΆαααα‘αΎαα§αααααααΆαααΆαααΆαααΎαα‘αΎαααα»α (Surge Protection) αααα’α·α ααΌαααΎα ααα α»ααααα»αααΆααααααΎα SPD αα·ααα·ααΈααΆααααααα½ααα»α.
ααα α»αααααααΌαα αααα»αααΆααααααΆααααααααααΎααααα»αααΌα’αααα·αααΈ (Distribution Boxes)
| ααα α»α | ααΌαα ααα»αααααΆααΆααααααααααΆαα | ααΆαα’αα»ααααααα’αααααΎαααΆααα»α |
|---|---|---|
| ααΆααααααΆααααααααΊα (Neutral) αα·αααααααΈ (Ground) αααα»αααΌα’αααα·αααΈαα (Subpanel) | α ααααα’αααα·αααΈαααα»αααααααΊαα’αΆα α αΌαααΆαααααΌαααααααΈ αααααααα αααααααααααΆα αα·αααα»αα§ααααα | αααααΆααααααΊαα±αααα ααΆα ααααα‘αα αα·ααααααΆαααααΆαααααααΈ (PE/Grounding bar) αα ααΉααααααααΌ |
| ααΆαααΆααααααααΊα αα·αααααααΈαα αααααα ααα»α αααααΆαα (Terminal) αααα½α | ααΆααααααΆαααα·αΰΉΰΈΰΉΰΈ ααΆαα‘αΎαααααα ααααΆαα αα·αα αΆαα·αααααααΆααααααααΎααααααΆα/αααααΈαααααααα·ααα | ααααΎααααΆααα ααα»α αααααΆαα (Terminals) ααααααΆααααααΈαααααααααααααΆααα ααα αΆαααααΎα αα·αααΆαααααΆαααααα’αααααα·α |
| ααΆααααααααααααααΆαααα (Main bonding jumper) | α ααααααααα’αΆα ααΉααα·αααααΌαααΆαααΆααααααΆα αααααΉαααααΌα α αΎααααα’ααααΆαααΆα (Enclosure) α’αΆα ααΉααα·αααααΌαααΆαααααΆααααΈ (Bonded) ααααΉαααααΌα | ααααΆααααΈ (Bond) αα αααααα ααα»α αααααΆαααααααααΆαααααα α¬α ααα»α ααααααααααααααααΎααααα‘ααααααα»ααααα |
| ααΆαααααΎααααΆαααααΆαααΈ (PE bar) αααα½ααααΆαααΊα (Neutral bar) | αααααααα ααααααΆααααααΆαα’αΆα ααΆαα αααααααα‘ααααααααΆααααααΆαα | αααααΆααΆααααα αααα»αααΆααααΆαααααααΊα (N) αα·αααααααΈ (PE) α±ααααΆα αααΈααααΆ |
| ααΆααα·ααααααΆαααααα PE ααααα§αααααααΆαααΆαααααα (SPD) | ααααΌααααα ααα αααααααααααΆααααααααααααα αα·αααααα α¬ααααΆαααααα·αααααΆα | αααααΆαααα PE αααα SPD α±ααααααΈ αα·ααααααααΆαααααΆααααΆααααααΆαααααα |
| ααΆαααααΎααααΆαααααΆαααααΆαα (Busbar) αααααΆαααα αααΌα ααα α¬ααΆαααΆααααααΆααα αααΎαααα | α ααα»α αααααΆααα‘αΎαααααα ααααΆαα ααα»α α¬αα·ααΆααααα»αααΆααααα½ααα·αα·ααα | ααααΎαααΎααααΆαααααΆαααααααΆαααααα·αα ααααα’αααα·αααΈ αααααααΆαα ααα»α αααααΆαα αα·αααα αααααααααΎααααααα |
| ααΆααα·ααααααΆααααααααΈ (Bonding) αα ααΉααααααααα ααααα’αΆα αααα ααααΆα | ααααΆα α¬ααααααααααΆααααα‘αΎαα§αααααα’αΆα ααΉααα·αααΆαααααΌαααΆαααΆααα»ααααα·ααΆααααα’αΆα αα»αα α·αααααΆα | ααααΎαααααααααΆαα (bonding straps) α¬ααααα αααααααααααΌαααΆαα’αα»ααααΆααα ααααααααααααααΌα |
| ααΆααααααααΆαααααΊαααααααααΆαααααααΆααααΆααααααα’ααααααααΆα | αααααααααααΎαααΆαααΆααα»αααααΆαα ααΆαααααα α αΎαααΆααααααΎαα αΆαααα’αΆα ααΉααα·αααΆαααΆααααΈαααααΆααααααΆ | αααααααααΆααααΆααα»αααΆα ααααΌαααΆα αα·ααΈααΆαααααααΆααααα αα·αααΆαααΆααααααΆααααααΆ |
αααααΆααααΆαααααΎαααΎαααααΏαααα·ααααΆααααααΆααα±ααααΆααααααΌααααΌααΆα αα½αααα·αααααααΆααααααΆαααααα (terminal block) αα·α ααααα»αααααααααααΎαααΎααα»ααααααΆαααααα ααΆααααααααααα ααααα ααΆααααΆαααααααΆ α¬α§αααααα ααα αΆαααΆααα.
αααααααααα’ααααααααΆααααΆαααααα’ααααΆααααΉα (Neutral) αα·αααααααΈ (Grounding) αα αααα»αααααΆααα ααα αΆαααααΎα
αα»αααΉαααα’ααααΎααααα»ααααα½αα ααΌααααααα’ααααααααΆααααΆα (Busbar) αααααα’ααααΎαα»αααΆα ααΆαααα‘αΎα ααΆαααααΆααααΈ (Bonding) ααΆαααΆααααααΆααααααΆ αα·αααΆααααααΆααααααα.
ααΆααααααα’ααααααααΆααααΆαααααα’ααααΆααααΉα (Neutral Bar)
αααΆαααααα’ααααΆααααΉαααΆααΌαα ααΆαααααααααΌα ααΆααααααα
- ααΆαααΆααααααΆααααααΆ N, Neutral α¬ααααααααααΆ
- αααααΆαααα ααΉαααααα’ααααΆααααΉα
- ααΆα ααααα‘ααααΈαααααααΌ (Enclosure) αα αααα»ααααααα ααα αΆαααΆααααααααααΆαααααα (Downstream panels)
- αααααΆαααα ααΉαααααα’ααααΆααααΉαααααααααααααααααααααααΆααα (Service neutral) α¬ααααΌαααααααα’ααααΆααααΉααααααααααα
- αααα αα‘αΎααααα»ααααααααααααααα’ααααΆααααΉαααΈαα½ααααααΎααααΆαααα·ααΈααΆααααααααααΆααααΆαααααΆααΈααααααααΌαααΆαα’αα»ααααΆα
αα αααα»ααααααα’αααα·αααΈαα α’αΆαααα·αααΆαααΎα ααααααΊα (Neutral) ααΆααΏααααΆααααα α¬αααααααααα αα αααα»ααααααααα IEC ααΆα αααΎα ααααααΊαααΆαααααααα αα»αααααΎαααααΆαααααααΆααααα½αααααααα»αααΆαααααΎαααααα.
ααΆααααααα’ααααααααΆααααΆαααΈ (Grounding Bar) α¬αααΆα PE (PE Bar)
αααΆαααΈ α¬αααΆα PE ααΆααΌαα ααΊα
- ααΆαααΆααααααΆααααααΆ PE, Earth, Ground α¬ GND
- αααααΆαααα ααΉααααα’ααααααα ααααααααααααααΌα
- αααααΆαααα ααΉαααααααΆαααΆαααΈ (Protective earth conductors)
- αααααΆαααα ααΉααααααααααΆαααααααΆααααααααααααα’ααααα
- ααααΎααΆα ααα»α ααααααααΆααααΆααααααΆαα SPD PE αα αααααααααααΆααα ααΆαααααΌαα±ααααΆα
αα α’αΆαααα·αααΆαααΎα ααααααΈ (grounding conductors) ααΆαα αααΎαααΆααααααααα α¬ααΆααααααααα αα αααα»ααααααααα IEC αααα PE ααΆαα αααΎαααΆααααααααααΆαααΏαα.
ααααΆαααααααααααΆααααα½ααα·αα·ααααααααααααα»ααααα·ααΆα
αα»αααααααααααΆααα α¬αααααααααααα ααα αΆαα’αααα·αααΈ α’αααααααΆααααααΆαααααααα·α αα αα½ααααααααααααΆααα
- ααΎααααααααααΆα§ααααααααααααααΆαααα (service equipment) ααααααα (subpanel) αααααα ααα αΆα (distribution board) α¬α ααα»α ααααααααααααααααΎααααα‘ααααΈααααΆ (separately derived system point)
- αααααααααααΆααααααΆαα N-PE ααααΌαααΆαα’αα»ααααΆα α¬αααααΌαα±ααααΆα
- ααΎαααΆαααΊα (neutral bar) ααααΌαααΆααααα ααααΈαααααααΆαααΆα (enclosure) αααα»αααααΈααααααααΌααααα¬αα
- ααΎαααΆα PE ααααΌαααΆαααααΆαααα ααΉααααααααΆαααΆααααα¬αα
- ααΎα§ααααα RCD, RCBO αα·α SPD ααααΌαααΆααααααΆαααα α ααα»α N/PE αααααΆααααααααααΉαααααΌααααα¬αα
- ααΎααΆααααααΆααααααα αααααΆαααΆααααΈααααΆααΉααααααΈααααααααααα ααα αΆαααααΎα αα·ααααΆαααααΆαααααα¬ααα
- ααΎααααΆααααααΆαααααΆααααΆαααΆααααΈααααΆααΉαααααΌαααααααααα¬ααα
ααΆααααα½ααα·αα·ααααα ααΉαααααααα ααΆαααααΎαααααα ααα½αααΈααααααα αΆαααΈααΆααααααΆαα N-PE ααααα·αααααΉαααααΌαα

ααΆααααα½ααα·αα·αααααΆαααααααΊαααααΆαααααα»ααααα·αα’αααα·αααΈαααααΆαααααααα·α αα ααα»αααααα ααΆααΆααααααααααααααΆαααααΆααααααΆαα N-PE ααααα·αααααΉαααααΌα ααΆααΏααααΎααα α αΆααααΌα ααΆααααΉαααααΌαααΆααααααααα αα αΌαααΆααααααΆαααΆαααΆαααααααΎααααααΈα.
- ααΆααααα½ααα·αα·αααααΆαααααααα αααααααα»αααααΆαααΆαααααΆαααΆαααα’αααα·αααΈα. αα αααααααααααα ααα αΆαααααΎααααααααΆααααααααααΌαααΆαααααΆα αα αα αα·ααααααααααΆααααΆααααΆαααΆαααα’αααα·αααΈ ααΌαααααΎααΆαααΆααααααααΆααααΆα Neutral αα·ααααΆα PEα αα αααα»ααααααα ααα αΆααα α¬αααααα ααα αΆαααααΎααααααααΆαααααα ααααααα N αα·α PE αα½αααααααΌαααΆααααααα ααααΈααααΆ αα½αααΆαα·ααα½ααααα αΆαααΈααΆααααααΆααααααΆαααααααα ααΆαα’αΆααααααααΆααααααΆααααα αΆαααΆ α αΆαααΆα αααααΌααα·αα·αααααΎαααΈααααααΆαα ααααααααΆαααααααΆαα ααααΆααΈααααααΆαααα½α α¬ααααΌαα ααααααααααα»ααααααΆααααααΆααα.
- ααΆααααα½ααα·αα·αααα αααααα ααΎαααα PE αααα»αααααΆαααΆαααΆαααααα»αα. αα ααααααααααααααα»αααααΎαααΆα αα·αααΆαααααα»αααααααΆ ααΌαααααΎα§αααααααΆααα αααα (Clamp meter) αααααΎαααα PE αα α¬ααααααΈααααααααααααααα αααααα ααα αΆαααααΎαααΆααααααα αα αααα»αααααααααααααααααααΆαααααΉαααααΌα α ααααααααααα»αααααααΆαα·ααα½ααααα‘ααααΆααααα PE α‘αΎαα ααΆαααΆααααΎαα αααααα ααΎαααα PE ααααααααΆαααααα»αααααααΆ ααΆααΏαααααα αΆαααΈααΆαααα ααααΆαα ααααααΆαααααΌααααα‘αααααααα Neutral ααααααααΆ α¬ααΆαααΆααααααΆαααα»ααααΆααααα Neutral αα·ααααα PE (N-PE)α.
- ααΆααα·αα·αααααααααααΆαααα RCD/RCBOα. ααααα·αααΎ RCD α¬ RCBO ααΆα αααααΎα (Trip) αα αααααααΆααααααααΈααΆααΆ α¬ααααα»αααΆαα½αααΆααααΆαα ααΌαααααΆα αααααααΈαααα αα α αΎααα·αα·αααααΎαααΆααΎαααα Neutral ααααΌαααΆαααααΆαααα»ααα ααΉααααΆα (Bar) αα»α α¬ααααΌαααΆαααααΆαααα ααΉααααα PE αα αααααααΆααααααααα§αααααααααααα¬ααα αααα»αααΆααααααααΆααααα αΆαα ααΎαααααα ααα αΆαααααΎα ααΆαααΆα αααααΎααααααααΆαααΌαα ααα»α αααΆααααΆαα (Nuisance tripping) ααΊααΆαααααΆαααα αΆα α αΎαααΌαα ααα»ααΊαααααΆαααααΈααΆαααααΆαααα»ααααΆααααα Neutral αα·ααααα PE (N-PE bridge) αααααΆααααααΆααα.
αααααΆααααΆααααααα α α·αααααΎαααααααΌααααΎα ααΌαααΎαααΆαααααΆααααα VIOX ααααΈααΈ ααααααααααΆααααα‘αΎαα§ααααααααα»αααΌααααΎα (Electrical enclosure mounting plates) αα·α αααααααα·ααααααα’ααα ααα αΆαααααΎα (Distribution box).
αααα½ααααα½αααΉαααΆαα
ααΎα’αααΈααΆααΆααα»αααααΆααααΆαααααΆααααΆα Neutral αα·ααααΆαααΈ (Grounding bar)?
αααΆα Neutral ααααΆαααα ααΉααααα Neutral α αΎαααΆααααααΆααΆαααα»αα αααααααα‘ααα αααΆαααΈααααΆαααα ααΉαααααααΆαααΆαααΈ (Protective earth) α¬ααααααΈααααα§ααααα α αΎαααΆααααααΆααΆαααα»αα αααααααααα»αααααΈααΆαααΆαααααα αααααα»αααααααααΈ (Fault conditions) ααα»αααααα.
ααΎαααΆαααΈ (grounding bar) ααΌα ααααΆαα ααΉααααΆαααΈ (earth bar) α¬αααΆα PE (PE bar) αααα¬αα?
αα αααα»αααααααααααΆααααααααΆα IEC ααΆα αααΎα ααΊααΌα ααααΆα αααΆαααΈ (Grounding bar), αααΆαααΈ (earth bar) αα·ααααΆα PE (PE bar) ααΆααΌαα αααα αα ααΎαααΆααααααααΎαααααΆααααααααΆαααΆαααΈ (protective earth conductors)α ααΆαααααΎααααΆααααΆααααα αα αααααααΆααααΆααααΊα’αΆααααααα ααΎααΈααααΆα αα·ααααααααΆαααααΆααααααΆααααααααααΎαα.
ααΎααααααΊα (neutral) αα·αααααααΈ (ground) α’αΆα ααΆαααα ααΎαααΆααααα½αααΆααααα¬αα?
ααΆααααα αααααα ααα»α αααααΆαααααααΆααααααααα»ααααα ααΌα ααΆα§αααααααααΆαααα α¬α ααα»α ααααααααααααααααΎαα‘αΎααααα‘αα αααααΌαα’αα»αααα αα·αααΆααα ααΆα§αααααα’αα»ααααΆαα±ααααααΎααΌα ααααα αα αααααααΆαααααα (downstream) ααααΌαα αΆαααα»α N αα·α PE ααΆα ααααα‘ααααΈααααΆ ααΎααααααα―αααΆαααααααααΆααααααΆαααααααααΈαααα.
α ααα»α’αααΈααΆαααΆααααααΊα αα·αααααααΈααααΌααααααααα ααααΈααααΆαα αααα»αααααΆααα ααα αΆααα (subpanel)?
ααΈαααααααΆααααααΆαα N-PE ααΈααΈαααΉααααααΎαααααΌααααα‘ααααα ααααααααααααΆα αααααΆααααααΆαααα αααα ααΉαααααααααΊααααααΆαα αααααα αααα»α PE ααα‘α»ααααααααα·ααααα·ααΆααααα»αααααααΆ; PE αα·ααα½ααααα»αα αααααααα‘ααααααααααΊααααααααααααα.
ααΎαααΆαααΈαααα»αα αααααααα¬αα?
αααα»αααααααααααααααΆ ααΆαα·ααα½ααααα»αα αααααααα»α (load current) αααααα ααΆα’αΆα αααα»αα αααααααα»αα’αα‘α»ααααααΆαααΆαααααα αααα (fault), ααΆαααΎαα‘αΎαααααα»α (surge event), ααΆαααα ααααΆαα αααα (leakage event) α¬αααααααααα·αααααααααΈαααααααα α’αΆααααααα ααΎααααααααααΆαααΆαα.
ααΎαααΆαααααα’ααααΆααααΉα (Neutral bar) α αΆαααΆα αααααΌαααΆααααααΆααααΆαααΆαα’ααΈααΌα‘αααααα¬αα?
αα αααα»ααααααα ααα αΆαααΆααααααααααΆαααααα (Downstream panels) ααΆααΌαα ααΊααααΌαα αααΆαααααα’ααααΆααααΉαααααΌαααΆαααα‘αΎααα ααΎααΎαααααααααΆαα’ααΈααΌα‘αα ααΎααααΈαα»αα±ααααΆαααααΆαα½ααα½ααΌαααα αα αααααα ααα»α αααααΆαααα (Main bonding point) αααααΆαααααα ααΆααααα αααΊααΆαααΆααα»αααααΆαααα ααααΆα.
ααΎααΆααααααααΆα IEC ααα α αααΆαααααααΈ (Ground bar) ααΆααΌα ααααα ?
ααΆααααααααααΎααΆααΌαα ααΆααααααααΆα IEC ααΊ PE bar α¬ Earth barα PE ααΆααααααΆ Protective Earth (ααααααΈααΆαααΆα)α.
ααΎααΉαααΆαα’αααΈααΎαα‘αΎαααααα·αααΎαααα»αααααΎαααΆα PE αααα½ααααΆαααααα’ααααΆααααΉα?
α’αααααΉαααααΎα±ααααααααααααΆαααΆαααααΆαααΆααααααα½αααααααΌααααα‘ααααα ααααααααααΆα αααααΊααΆα’αααΈααα PE ααααΌαααΆααα ααΆα‘αΎαααΎααααΈαααααΆαα.
ααΎααΆαααααΆαααααααΆαααα‘αΎαα§αααααααΆαααΆαααααα (SPD) αααΆαααΌα ααααα ?
α§ααααα SPD ααααΌαααΆαααΆααααααΆααααααΉαααααΌα αα·αααααΈαα ααΆαα PE αα·α/α¬ N α’αΆαααααααΎααααααΆαααΆα αα·αααααααααααααααΈα ααΆαααΆααααΈααΆαααααΆα PE αα·αααααΉαααααΌα αααααααααΆαααααααα α¬ααΆααααααΆαα N/PE αα·αααααΉαααααΌα α’αΆα ααΆαααααααααααα·αααααΆαααααΆαααΆαααΆααααα ααααααΎα (Surge protection)α.
ααΎαα½αααααΎαααΎααααΆαα’ααααΆααααΉα (Neutral bar) αα·ααααΆαααΈ (Grounding bar) ααΌα αα ααΉααααα»ααααααΆααααααααααΎα (Terminal blocks) αααα¬αα?
αα½αααΆαα½αααααΌαααΆαααααΎαααΎααααααα’ααααΎααα αααααα αααα ααααα·αα ααααα’αααα·αααΈ αααααααΆαααα ααα»α αααααΆαα αααααΆαα αα·ααΈααΆααααααααααΎα αααααΌαααΆαα’ααΈααΌα‘αα αα·αααΆααααααΆααααΆααααααααΆα α¬ααΆααα ααΆαααααααααα ααα αΆαα’αααα·αααΈα αα½αααΆαα·ααααααααΆααααααΆααααααααααΌαα αααααα.
ααα ααααΈααααα·
αααΆαα’ααααΆααααΉα αα·ααααΆαααΈα’αΆα ααΎααα ααααααααααΆ ααα»αααααα½αααΆααΆααα»αααΆααα»αααααΆα αααΆαα’ααααΆααααΉαααΊααΆααααααα½αααααααΌααααα‘ααααα ααααααααααΆα α αααααααΆαααΈ (Grounding bar), αααΆα PE α¬αααΆαααΈααΆαααΆα (Earth bar) ααΊααΆααααααα½αααααααΌαααΆαααΆααααααΆαααα α»ααααα αα·αααααααααααααΆααααΈα.
αααααΆαααααααα ααα αΆαα’αααα·αααΈαα α¬ααααααααααα»ααααα ααααΆα αααα½ααααααΉαααΊααΆααΎα’ααααΆααααΉα αα·αααΈααααΌαααΆαααααΆααααααΆαα αααααααΆα αααααΆαααααααα ααα αΆαα’αααα·αααΈααΆααααααααΆα IEC αα·αααΆαααΆαααα‘αΎααααααα ααα αΆα αααα½ααααααΉαααΊααΆααΎ N αα·α PE ααααΌαααΆααααααα ααααΈααααΆαααΆαααΌα ααααα αααααα αααΆααααααααααααΈαααααα TN-S, TN-C-S, TT α¬ ITα.
αα·ααΈααΆααααααα ααΆαααααΆααα»ααααα·ααΆααααα»αααΊααΆααααα αααααΆ α αα·α αα»αααΆα PE α±ααααΆα ααααα‘ααααΈααααΆ ααααΆαααα½αααΆααααΉααααα α ααα»α αααα’αα»ααααΆαααα»ααααα αααααΆααααααα ααααααΆαααΆααααααΆαααααααααααα ααα αΆα αα·ααααα αααΆααααααΆαα RCD/RCBO/SPD αα ααΆαααΆααα ααΆααΆαααααααααααααααααα.
Sources Reviewed
- α’ααααααα αα α»αααααααααα VIOXα αααΆαα’ααααΆααααΉα αααααΉα αααΆαααΈ
- αααααΆααα NECα αααααΆαααα·ααααΆα’αααΈααΆαα α»αααΈ (Grounding) αα·αααΆααααααΆαα (Bonding) αααααΆαααΆααααΆ α’α₯α
- EC&Mα αααααΌαααΆααααα NEC αααααΆααααΆαα α»αααΈααααααααααααααααααααααΆααα (Services)
- Siemensα αα·αααααΆαααΌαα ααααααααααααααααααααααΆααα αα·αααΆαα α»αααΈαααααΆααααααααΆα IEC 60364