VIOX ELECTRIC
Γλώσσα

VIOX VOPV-20 1000VDC 20A 8×31.5mm Solar Light PV Fuse Holder

VOPV-20 Holder VIOX Electric’s VOPV-20 1000VDC 20A 8×31.5mm Solar Light PV Fuse Holder has been engineered to meet the emerging circuit protection needs for the 1000VDC Photovoltaic (PV) system. The recommended fuse link size is 8×31.5mm, which can effectively protect 1000VDC.

Σειρά VIOX
VOPV-20
Ονομαστική τάση
1000VDC
Ονομαστικό ρεύμα
20A
Πρότυπο
IEC 60269

Επισκόπηση

VOPV-20 Holder VIOX Electric’s VOPV-20 1000VDC 20A 8×31.5mm Solar Light PV Fuse Holder has been engineered to meet the emerging circuit protection needs for the 1000VDC Photovoltaic (PV) system. The recommended fuse link size is 8×31.5mm, which can effectively protect 1000VDC Photovoltaic (PV) systems. The main application of this VOPV-20 1000VDC 8×31.5mm PV Fuse is Solar Photovoltaic (PV) Street Light (Lamp). VOPV-20 1000VDC 8×31.5mm PV Fuse Holder was made by the flame-retardant shell with V0 standard, and the compact design contributed to low-temperature rise when the holder was installed into a Photovoltaic (PV) system.

1000VDC 20A 8×31.5mm Solar Light PV Fuse Holder

Χαρακτηριστικά

  • Rated voltage 1000VDC and current capacity 20A for solar pv protection fuse applications.
  • High interrupting performance (High Breaking Capacity) with rapid current-limiting fault clearing.
  • Engineered and tested in accordance with IEC 60269 standards.
  • Precision-engineered low-power-loss silver-plated contacts and high-temperature ceramic or flame-retardant housing.
  • Direct OEM replacement geometry for standardized industrial, solar PV, ESS, and EV protection panels.

Προδιαγραφές

VOPV-20 Technical Specifications

Product code Ονομαστικό ρεύμα Ονομαστική τάση Safety certificate Recommended Fuse Link Model/Size Net weight
VOPV-20 20A 1000Vdc ● ● ○ VOPV-20(Φ8×31.5mm) 37.5g

Selection & Installation Notes

  • Verify system maximum voltage (1000VDC) and prospective short-circuit fault current before selecting the fuse link or holder rating.
  • Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
  • Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
  • Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.

ΣΥΧΝΈΣ ΕΡΩΤΉΣΕΙΣ

What voltage and current ratings does the VIOX VOPV-20 1000VDC 20A 8×31.5mm Solar Light PV Fuse Holder support?

This VIOX VOPV-20 series is rated for 1000VDC with a current rating of 20A and High Breaking Capacity breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.

Which international standards apply to VIOX VOPV-20 1000VDC 20A 8×31.5mm Solar Light PV Fuse Holder?

The VOPV-20 series is designed and verified to IEC 60269 requirements for safe overcurrent and short-circuit protection.

Where is the VIOX VOPV-20 1000VDC 20A 8×31.5mm Solar Light PV Fuse Holder typically installed?

It is engineered for solar pv protection fuse circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.

Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?

Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.