⎯⎯ Low-Voltage Distribution · ACB

ACB for Low-Voltage Distribution Systems

VIOX ACB air circuit breaker solutions are built for switchboards, generator systems, industrial plants, and large commercial power distribution projects that require higher current handling, intelligent protection, and stable operating performance. The W1-2000 series product scope covers 630A to 6300A with fixed and draw-out configurations, 3P and 4P options, and intelligent trip unit support.

630A-6300A

Phạm vi dòng điện

3

Frame Sizes

2

Kiểu lắp đặt

⎯⎯ W1-2000 Series

Intelligent Air Circuit Breaker

Suitable for main incoming protection, bus coupler switching, and higher-capacity feeder protection in low-voltage power distribution.

2000A

Frame for 630A to 2000A

4000A

Frame for 2500A to 4000A

6300A

Frame for 4000A to 6300A

3P / 4P

Fixed or draw-out construction

Typical configuration options include intelligent trip unit, motor charging, shunt release, undervoltage release, and accessory logic for panel integration.

⎯⎯ Tổng quan

What Is an ACB?

An ACB, or air circuit breaker, is a low-voltage circuit breaker that uses air as the arc extinguishing medium when the contacts open under load or fault conditions. It is commonly used in higher-current power distribution systems where main incoming protection, bus coupler switching, selective coordination, and service accessibility are more important than compact breaker size.

Air as the Breaking Medium

The breaker interrupts current and extinguishes the switching arc in air, which makes ACB products suitable for low-voltage systems with higher current demand.

Main Distribution Protection

ACB products are often used as main incoming breakers, bus coupler breakers, or high-current feeder breakers inside switchboards and distribution assemblies.

High-Current Low-Voltage Use

Compared with smaller breaker platforms, ACB products are better suited to applications that need higher current coverage, service access, and more advanced protection control.

VIOX ACB

⎯⎯ Phạm vi sản phẩm

Các mô hình và danh mục hộp đấu dây

Khám phá thực tế hộp kết hợphộp kết hợp năng lượng mặt trời, Và Hộp kết hợp DC các nhóm mô hình theo cấp điện áp, cấu hình chuỗi, hướng vỏ bọc và bố cục bảo vệ bên trong.

Frame Platform

2000A Frame ACB

Suitable for current ratings from 630A to 2000A in low-voltage switchboards, main panels, and higher-capacity feeder positions.

Frame Platform

4000A Frame ACB

Designed for larger industrial and commercial distribution assemblies where higher current capacity and stable switching are required.

Frame Platform

6300A Frame ACB

Fits the upper-capacity side of low-voltage distribution systems where high-current switching and protection performance are critical.

Cài đặt

ACB loại cố định

Used where stable breaker mounting and straightforward integration into the panel structure are preferred.

Cài đặt

ACB loại kéo ra

Preferred when service accessibility, isolation during maintenance, and easier breaker replacement are important.

Điều khiển

Intelligent Trip Unit and Accessories

Supports protection, measurement, status display, and project-specific accessory logic such as motor charging and release modules.

⎯⎯ Technical Specs

ACB Technical Direction

ACB selection is usually confirmed by frame size, current band, installation type, voltage level, pole structure, interrupting requirement, and intelligent controller level. These factors help match the breaker to the real switchboard duty.

MụcTypical Coverage
LoạtW1-2000 Intelligent Air Circuit Breaker
Bình Hiện Tại630A to 6300A
Kích Thước Khung2000A / 4000A / 6300A
Cài Đặt LoạiFixed Type / Draw-out Type
Tùy chọn cực3P / 4P
Hệ Thống Điện ÁpTypical low-voltage applications at 415V / 690V
Tính thường xuyên50Hz / 60Hz
Bộ ngắtM / H / 3M / 3H intelligent controller options
Phạm vi bảo vệOverload, short circuit, undervoltage, ground fault logic
Accessory ScopeMotor charging, shunt release, undervoltage release, auxiliary contact

Configuration Highlights

ACB selection is usually confirmed by frame size, current band, installation type, voltage level, pole structure, interrupting requirement, and intelligent controller level. These factors help match the breaker to the real switchboard duty.

Switchboard Structure

Suitable for higher-current incoming distribution positions.

600V / 1000V

Fixed or draw-out mounting according to service workflow.

Accessory Expansion

Motor charging and release options for panel control logic.

Intelligent Monitoring

Bảo vệ chuỗi

⎯⎯ Ứng dụng

Các lĩnh vực ứng dụng

ACB products are usually selected where current level, switching duty, and selectivity requirement go beyond compact low-voltage breaker platforms.

Main Switchboards

Used as main incoming breakers in low-voltage switchboards for commercial buildings, industrial plants, and utility rooms.

Bus Coupler Sections

Suitable for sectionalizing and coupling duties where dependable switching and isolation logic are important.

Generator Systems

Used for generator outgoing protection and other applications where higher current and control coordination matter.

Industrial Distribution

Fits factories, process plants, production workshops, and load centers requiring higher-capacity feeder protection.

⎯⎯ Selection Focus

Why This ACB Layout Works

The page follows the main factors normally used when reviewing ACB products for quotation, comparison, and switchboard matching.

Frame and Current Logic First

The page starts with 2000A, 4000A, and 6300A frame logic because current coverage is usually the first step in ACB selection.

Installation Type is Separated Clearly

Fixed and draw-out types are presented as distinct choices so maintenance strategy and switchboard design are easier to compare.

Trip Unit and Accessories are Included

Many ACB decisions depend on controller level and accessory logic, so those points are kept in the main comparison flow instead of being hidden.

RFQ Path is Kept Simple

The page closes with the exact project details that are most useful for ACB quotation, helping the buyer move from product review to inquiry faster.

⎯⎯ Câu hỏi thường gặp

Frequently Asked Questions About Cable Tie Products

An ACB air circuit breaker is used in low-voltage distribution systems as a main incoming breaker, bus coupler breaker, or higher-current feeder breaker. It is commonly selected for switchboards, generator systems, industrial plants, and large commercial power assemblies.

The VIOX ACB product scope covers current ratings from 630A to 6300A across 2000A, 4000A, and 6300A frame sizes, which helps organize the range for different low-voltage distribution capacities.

Fixed type ACB is commonly used for stable panel integration, while draw-out type ACB is generally preferred when service access, isolation during maintenance, and easier breaker replacement are important in the switchgear workflow.

ACB products commonly include different intelligent controller levels such as M, H, 3M, and 3H options. The right choice depends on the required protection functions, operating display, monitoring depth, and communication needs.

For a faster quotation, send the rated current, frame size, number of poles, fixed or draw-out preference, working voltage, accessory requirements, application, and target quantity. This helps match the correct ACB configuration more efficiently.

⎯⎯ Yêu cầu báo giá

Discuss the Right ACB Configuration

VIOX supports ACB product selection for low-voltage switchboards, generator systems, industrial distribution panels, and higher-current incoming or feeder applications. Share your project basics and we can match the frame size, installation type, pole structure, and accessory set more efficiently.

Cho chúng tôi biết yêu cầu của bạn

Yêu cầu báo giá ngay