VIOX Electric
Language

DC Miniature Circuit Breakers (ڈی سی ایم سی بی)

Compare the published VIOX VOB3-63DC, VOB6-63DC and VOB2-125DC series for direct-current circuit protection in solar PV, battery, telecom and industrial DC systems.

براہ راست کرنٹDC-specific interruption

Series configurationVerify poles and polarity

63A / 125APublished current platforms

250V–1200V classesConfirm exact series data

VIOX DC MCB SERIESشائع شدہ پروڈکٹ رینج

ڈی سی ایم سی بی (DC MCB) کیا ہے؟

A DC miniature circuit breaker is designed to interrupt overload and short-circuit current in a direct-current circuit within its published voltage, pole, polarity and breaking characteristics.

DC arcs do not pass through a natural current zero in the same way as AC arcs. The breaker construction and required series-pole arrangement must therefore be selected from explicit DC ratings rather than inferred from an AC device.

Normal DC currentThe selected breaker carries load current within its approved characteristics.
Overcurrent occursThermal or magnetic operation responds according to the device design.
DC arc is interruptedThe approved pole and arc-control arrangement opens the circuit within its published rating.

How to choose a DC MCB

Start with maximum system voltage and fault conditions, then verify poles, polarity and circuit coordination.

Maximum DC voltage

Confirm the worst-case circuit voltage and the required pole arrangement from the exact datasheet.

Current and breaking capacity

Coordinate rated current with conductor capacity and verify prospective DC fault current.

Poles and polarity

Follow the approved wiring diagram, including any series-pole or polarity requirements.

Application coordination

Check source behavior, upstream and downstream protection, isolation and environmental conditions.

Treat DC interruption as a system decision

A matching current number is not enough; voltage, pole arrangement, polarity and available fault current determine suitability.

ویMaximum direct-current voltage
میںLoad and prospective fault current
پیPole arrangement, polarity and wiring
Read the DC MCB selection guide

Compare published DC MCB series

خالی خانے کا مطلب ہے کہ موجودہ پروڈکٹ سمری میں یہ ویلیو دستیاب نہیں ہے۔ تفصیلات (specification) سے پہلے ماڈل کا صفحہ کھولیں یا اس کا ڈیٹا شیٹ طلب کریں۔.

سیریزCurrent platformسسٹمکھمبےڈی سی وولٹیج
VIOX VOB3-63DC63Aبراہ راست کرنٹ
VIOX VOB6-63DC63Aبراہ راست کرنٹ
VIOX VOB2-125DC125Aبراہ راست کرنٹ

DC MCB Selection Questions

تفصیلی سرکٹ کی تصدیق سے پہلے پروڈکٹ فیملی کے ابتدائی موازنہ کے لیے فوری جوابات۔.

Can an AC MCB be used in a DC circuit?

Only if the manufacturer explicitly publishes the required DC voltage, pole and wiring configuration for that exact device. Do not infer DC suitability from an AC rating.

Why can multiple poles be connected in series?

Approved series-pole arrangements can divide the DC voltage and support arc interruption, but only the wiring shown for the exact model may be used.

کیا پولرٹی (قطبیت) اہم ہے؟

Some DC breakers are polarity-sensitive and others publish polarity-independent arrangements. Follow the selected model markings and diagram.

How is rated current selected?

Coordinate continuous load, conductor capacity, ambient conditions and protective characteristics, then verify the exact datasheet.

Which details are needed for selection?

Provide maximum DC voltage, load current, source and battery or PV details, available fault current, poles, wiring arrangement, quantity and target market.

Need the Right DC MCB?
Let’s Verify the DC Circuit.

Send the maximum DC voltage, load current, source type, available fault current, poles, wiring arrangement, quantity and target market.

Request DC MCB Support