ภาพรวม
VOSA1-GK 1500V Rated DC 1500V from 80A to 315A, the 1500V DC Branch-Circuit Semiconductor Protection Fuse from VIOX is an aR-class element with 150kA breaking and ≤15ms time constant, CE marked to IEC 60269-4 and GB/T13539.4, for solar, storage and charging branch circuits.
Branch circuits inside 1500V DC equipment face the same destructive fault energy as the main bus, yet they are often protected with whatever space and budget remain. VIOX Electric developed the 1500V DC Branch-Circuit Semiconductor Protection Fuse to remove that compromise, an aR-class device for 80A to 315A feeders that shields IGBT modules, thyristors and rectifier diodes in solar and storage converters, charging cabinets, telecom DC rooms, rail auxiliary supplies and industrial drive cubicles.
คุณสมบัติ
- Rated voltage 1500VDC and current capacity 80A for ess & semiconductor high-speed fuse applications.
- High interrupting performance (150kA) with rapid current-limiting fault clearing.
- Engineered and tested in accordance with GB/T 13539.4 / GB/T13539.4 / IEC 60269-4 standards.
- Precision-engineered low-power-loss silver-plated contacts and high-temperature ceramic or flame-retardant housing.
- Direct OEM replacement geometry for standardized industrial, solar PV, ESS, and EV protection panels.
ข้อมูลจำเพาะ
VOSA1-GK Technical Specifications
| หมายเลขซีเรียล | Rated Current A | Pre-arcing I²t A²s | Melting I²t A²s | Power dissipation W |
| 1 | 80 | 1800 | 9400 | 45 |
| 2 | 100 | 3230 | 16000 | 54 |
| 3 | 125 | 6400 | 27200 | 63 |
| 4 | 160 | 10710 | 44800 | 74 |
| 5 | 200 | 18400 | 96400 | 86 |
| 6 | 250 | 35100 | 190000 | 96 |
| 7 | 315 | 46900 | 253000 | 105 |
VOSA1-GK Ratings & Dimensions Table 2
| Rated Current (A) | Conventional Time (h) | Conventional Current | |
| “gR” | |||
| Inf | lf | ||
| ln≤63 | 1 | 1.13ln | 1.6ln |
| 63<In≤160 | 2 | ||
| 160<ln≤400 | 3 | ||
| 400<ln | 4 | ||
| Note:ln is the rated current of the fuse; lnf is the conventional non-fusing current; if is the conventional fusing current. | |||
Selection & Installation Notes
- Verify system maximum voltage (1500VDC) and prospective short-circuit fault current before selecting the fuse link or holder rating.
- Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
- Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
- Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.
คำถามที่พบบ่อย
What voltage and current ratings does the VIOX VOSA1-GK 1500V DC Branch-Circuit Semiconductor Protection Fuse support?
This VIOX VOSA1-GK series is rated for 1500VDC with a current rating of 80A and 150kA breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.
Which international standards apply to VIOX VOSA1-GK 1500V DC Branch-Circuit Semiconductor Protection Fuse?
The VOSA1-GK series is designed and verified to GB/T 13539.4 / GB/T13539.4 / IEC 60269-4 requirements for safe overcurrent and short-circuit protection.
Where is the VIOX VOSA1-GK 1500V DC Branch-Circuit Semiconductor Protection Fuse typically installed?
It is engineered for ess & semiconductor high-speed fuse circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.
Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?
Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.