VIOX ELECTRIC
Язык

VIOX HR17 690VAC 160A Horizontal 3P Fuse Switch Disconnector

HR17 160A 3P VIOX YR:HR17-690VAC 160A Horizontal 3P Fuse Switch Disconnector is suitable for short circuit protection and overload protection of cable and power equipment of the distribution system. In the case of a short circuit, the current can be broken by the fuse link inside.

Серия VIOX
HR17
Номинальное напряжение
690VAC
Номинальный ток
160A
Стандарт
IEC 60269

Обзор

HR17 160A 3P VIOX YR:HR17-690VAC 160A Horizontal 3P Fuse Switch Disconnector is suitable for short circuit protection and overload protection of cable and power equipment of the distribution system. In the case of a short circuit, the current can be broken by the fuse link inside. With the features of high isolating function and high durability, YR:HR17-160/3 Horizontal Fuse switch disconnector can withstand high short circuits.

690VAC 160A Horizontal 3P Fuse Switch Disconnector

Характеристики

  • IEC60947-3
  • Rated voltage 690VAC and current capacity 160A for hrc fuse switch disconnector applications.
  • High interrupting performance (High Breaking Capacity) with rapid current-limiting fault clearing.
  • Engineered and tested in accordance with IEC 60269 standards.
  • Precision-engineered low-power-loss silver-plated contacts and high-temperature ceramic or flame-retardant housing.
  • Direct OEM replacement geometry for standardized industrial, solar PV, ESS, and EV protection panels.

Технические характеристики

HR17 Technical Specifications

Model / Size Номинальное напряжение (В) Номинальный ток (A) Power Frequency Withstand Voltage (V) Recommended Fuse Link Model/Size Габаритные размеры
A E H H1 B
YR:HR17-160/3 690V 160A 3000V NT00C, NT00, NH00C, NH00 202 106 83 208 65

Selection & Installation Notes

  • Verify system maximum voltage (690VAC) and prospective short-circuit fault current before selecting the fuse link or holder rating.
  • Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
  • Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
  • Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.

ЧАСТО ЗАДАВАЕМЫЕ ВОПРОСЫ

What voltage and current ratings does the VIOX HR17 690VAC 160A Horizontal 3P Fuse Switch Disconnector support?

This VIOX HR17 series is rated for 690VAC with a current rating of 160A and High Breaking Capacity breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.

Which international standards apply to VIOX HR17 690VAC 160A Horizontal 3P Fuse Switch Disconnector?

The HR17 series is designed and verified to IEC 60269 requirements for safe overcurrent and short-circuit protection.

Where is the VIOX HR17 690VAC 160A Horizontal 3P Fuse Switch Disconnector typically installed?

It is engineered for hrc fuse switch disconnector circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.

Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?

Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.

Нужен расчет стоимости продукции?
Давайте создавать вместе.

Отправьте нам модель изделия, технические характеристики, количество и требования OEM. Наша команда рассмотрит вашу заявку и ответит в течение одного рабочего дня.

Запрос Цитировать