Penderia Kehampiran Kapasitif 15mm KI5001
VIOX’s KI5001 capacitive proximity sensors provide non-contact detection of any material based on changes in electrical capacitance. With a 10-36VDC power supply, PNP normally closed (NC) output, and up to 15mm sensing range in a robust M30 metal cylindrical housing, the KI5001 ensures reliable detection for diverse industrial applications.
Hantar keperluan anda, kami akan sebut harga untuk anda dalam masa 12 jam
- TEL:+8618066396588
- Sila+8618066396588
- Email:[email protected]
| Model | KI5001 | KI0016 | |
| produk ciri-ciri |
Electrical design | PNP | |
| Fungsi output | normally closed | normally open | |
| Julat penderiaan (mm) | 15 | 15 | |
| Perumahan | Jenis berulir | Jenis berulir | |
| Dimensi(mm) | M30 x 1.5 / L = 81 | M30 x 1.5 / L = 81 | |
| Permohonan | Medium temperature(℃) | ||
| Elektrik tarikh |
Voltan kendalian (V) | 10-36 DC | 20-250 AC/DC |
| Current consumption(mA) | 13; (24 V) | ||
| Kelas perlindungan | II | II | |
| Perlindungan kekutuban terbalik | tidak | ||
| Output | Electrical design | PNP | |
| Fungsi output | normally closed | normally open | |
| Pensuisan jatuh voltan maks keluaran DC(V) |
2.5 | 8 | |
| Pensuisan jatuh voltan maks keluaran AC(V) |
10 | ||
| Arus beban minimum (mA) | 5 | ||
| Arus kebocoran maks (mA) | 2.5 (250 V AC) / 1.7 (110 V AC) / 1.5 (24 V DC) | ||
| Kedudukan semasa kekal bagi menukar output AC(mA) |
200; (for UL application: 250 / 100 DC) | ||
| Kedudukan semasa kekal bagi menukar output DC(mA) |
250 | 200; (for UL application: 250 AC / 100 DC) | |
| Kedudukan semasa masa pendek bagi menukar output (mA) |
1500; (20 ms / 0,5 Hz) | ||
| Kekerapan menukar AC(Hz) | 25 | ||
| Kekerapan menukar DC(Hz) | 40 | 40 | |
| Kalis litar pintas | ya | tidak | |
| Perlindungan beban berlebihan | ya | tidak | |
| Pemantauan julat |
Julat penderiaan (mm) | 15 | 15 |
| Julat penderiaan boleh laras | ya | ya | |
| Julat pengesan tetapan kilang (mm) | 15 | 15 | |
| Julat sening sebenar Sr(mm) | 15 ± 10 % | 15 ± 10 % | |
| Jarak operasi (mm) | 0-12.1 | 0-12.1 | |
| Ketepatan/penyimpangan | Faktor pembetulan | glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2 | glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2 |
| Histeresis (% daripada Sr) | 1~15 | 1~15 | |
| Hanyutan titik suis(% daripada Sr) | -15-15 | -15-15 | |
| Beroperasi syarat |
Suhu persekitaran(℃) | -27-70 | -25-70 |
| Perlindungan | IP 65 | IP 65 | |
| Peningkatan imuniti | yes; (Increased immunity to conducted radio frequency interference) |
yes; (Increased immunity to conducted radio frequency interference) |
|
| Ujian/kelulusan | EMC | EN 60947-5-2 | EN 60947-5-2 |
| MTTF(tahun) | 778 | 489 | |
| Data mekanikal | Berat(g) | 195 | 196 |
| Perumahan | Jenis berulir | Jenis berulir | |
| Boleh dipasang | tidak boleh dipasang siram | tidak boleh dipasang siram | |
| Dimensi(mm) | M30 x 1.5 / L = 81 | M30 x 1.5 / L = 81 | |
| Penamaan benang | M30 x 1.5 | M30 x 1.5 | |
| bahan | PBT | PBT | |
| Paparan | Paparan | Switching status 1 x LED, yellow | Switching status 1 x LED, yellow |
| Sambungan elektrik | Perlindungan yang diperlukan | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting |
|
| Aksesori | lock nuts: 2 | lock nuts: 2 | |
| Teguran | Teguran | Recommendation: check the unit for reliable function after a short circuit. | |
| Kuantiti pek | 1 pcs | 1 pcs | |
| Sambungan elektrik | Sambungan | Cable: 2 m, PVC; 3 x 0.5 mm² | Cable: 2 m, PVC; 2 x 0.5 mm² |