VIOX FCT18-Xd Asymmetrical On-Delay ແລະ Off-Delay Timer Relay ມີສັນຍານຄວບຄຸມ
The VIOX FCT18-Xd Asymmetrical Timer Relay offers both ON-delay and OFF-delay (0.1s-100 days) triggered by a control signal. <0.5% error, NPN/PNP, 1/2 SPDT, AC/DC 12-240V. Ideal for industrial automation needing precise, sequential timing for applications like conveyor or motor control.
ສົ່ງຄວາມຕ້ອງການຂອງທ່ານ, ພວກເຮົາຈະອ້າງອີງໃຫ້ທ່ານພາຍໃນ 12 ຊົ່ວໂມງ
- ໂທ:+8618066396588
- Whatsapp:+໘໖໑໘໐໖໖໓໙໖໕໘໘
- Email:sales@viox.com
ພາບລວມຂອງຜະລິດຕະພັນ
The VIOX FCT18-Xd is a versatile industrial-grade asymmetrical timer relay designed to provide precise ON-delay and OFF-delay timing control in a compact DIN rail mountable package. This sophisticated timing device offers exceptional flexibility with adjustable time ranges from 0.1 seconds to 100 days, making it suitable for a wide variety of industrial automation, process control, and equipment protection applications.
Engineered with dual timing functions (T1 and T2), the FCT18-Xd allows you to implement both rising edge (ON-delay) and falling edge (OFF-delay) timing sequences in a single device. The unit’s precision timing control, combined with its robust design and versatile power supply options, makes it an ideal solution for systems requiring accurate time-based switching operations.
ຄຸນນະສົມບັດແລະຜົນປະໂຫຍດທີ່ສໍາຄັນ
- Dual Timing Functionality: Integrates both ON-delay and OFF-delay timing functions in a single compact device, reducing panel space requirements and simplifying installation.
- ຊ່ວງເວລາກວ້າງຂວາງ: Features a remarkable time range from 0.1 seconds to 100 days, covering virtually all industrial timing applications from rapid cycling to extended process monitoring.
- ໄລຍະເວລາທີ່ມີຄວາມແມ່ນຍໍາສູງ: Delivers exceptional timing accuracy with less than 0.5% time error and 0.1% time deviation, ensuring reliable and consistent operation.
- Universal Power Supply: Supports a wide power supply range from 12 to 240 VAC/DC, eliminating the need for different models for various power sources.
- Adjustable Duty Cycle: Features ratio setting from 10% to 100%, allowing precise control over the ON/OFF cycle timing relationship.
- ຕົວຊີ້ບອກສະຖານະພາບ: Includes green LED for supply indication and red LED for relay status, providing clear operational feedback.
- Easy Configuration: Simple setup with intuitive controls for time and ratio settings, reducing commissioning time.
- Multiple Control Options: Available with NPN or PNP control signal compatibility for seamless integration with various control systems.
- ຄວາມສາມາດຕ້ານການແຊກແຊງທີ່ເຂັ້ມແຂງ: Built-in protection against electrical noise, ensuring reliable operation in harsh industrial environments.
- ການຕິດຕັ້ງລົດໄຟ DIN: Standard DIN rail mounting per EN/IEC 60715, simplifying panel installation and system integration.
- ຊ່ວງອຸນຫະພູມກວ້າງ: Operates from -20°C to +60°C (-40°F to +85°F), suitable for diverse environmental conditions.
Understanding the FCT18-Xd Timing Function
The FCT18-Xd provides a sophisticated timing function that combines both ON-delay (rising edge) and OFF-delay (falling edge) operations. When the control signal (S) is applied:
- On the rising edge (when S switches from OFF to ON), the relay output (R) remains OFF for duration T1 (ON-delay).
- After T1 elapses, the relay output (R) switches ON.
- On the falling edge (when S switches from ON to OFF), the relay output (R) remains ON for duration T2 (OFF-delay).
- After T2 elapses, the relay output (R) switches OFF.
This dual-timing capability allows the FCT18-Xd to handle complex timing sequences with a single device, eliminating the need for multiple timers in many applications.
ຕົວເລືອກການຕັ້ງຄ່າເວລາ
The FCT18-Xd offers an exceptional range of time settings to accommodate virtually any industrial timing requirement:
0.1-1ວິ | 1-10ວິ | 0.1-1ມ | 1-10ມ | 0.1-1ຊມ |
1-10ຊມ | 0.1-1 ມື້ | 1-10 ມື້ | 3-30 ມື້ | 10-100 ມື້ |
Each time range is easily selectable via the rotary switch on the front panel, allowing for quick configuration changes without rewiring or replacement.
Ratio Setting Capability
A unique feature of the FCT18-Xd is its adjustable ratio setting, which allows you to precisely control the timing proportion between different phases of operation. The ratio can be set from 10% to 100% in the following increments:
10% | 15% | 20% | 25% | 30% | 35% | 40% | 45% | 50% | 55% |
60% | 65% | 70% | 75% | 80% | 85% | 90% | 95% | 100% |
This flexibility allows for precise customization of timing cycles, making the FCT18-Xd suitable for a wide range of applications requiring specific ON/OFF duty cycles.
Model Variants and Selection Guide
The FCT18-Xd series is available in various configurations to meet different application requirements. The model number is structured as follows:
FCT18-Xd 1 W N
ຕໍາແໜ່ງ | ລະຫັດ | ລາຍລະອຽດ |
---|---|---|
1. ຫນ້າທີ່ | Xd | ON-OFF delay switching |
2. ປະເພດຜົນຜະລິດ | 1 | 1 CO contact |
2 | 2 CO contacts | |
3. ການສະຫນອງແຮງດັນ | ກ | AC230V |
ງ | DC24V | |
ວ | AC/DC 12-240V | |
4. ສັນຍານຄວບຄຸມ | ນ | NPN |
ປ | PNP |
ການຕັ້ງຄ່າສາຍ
The FCT18-Xd offers straightforward wiring options for both NPN and PNP control signal types:
ການຕັ້ງຄ່າ NPN:
- Connect the power supply to terminals A1 (DC+ / AC L) and A2 (DC- / AC N)
- Connect the control signal (S) input
- Output terminals: 11, 12, 14 for single CO contact version; 11, 12, 14, 21, 22, 24 for dual CO contact version
ການຕັ້ງຄ່າ PNP:
- Connect the power supply to terminals A1 (DC+ / AC L) and A2 (DC- / AC N)
- Connect the control signal (S) input
- Output terminals: 11, 12, 14 for single CO contact version; 11, 12, 14, 21, 22, 24 for dual CO contact version
ຂໍ້ມູນຈໍາເພາະ
FCT18-Xd Technical Specifications | ||
---|---|---|
ສະຖານີປ້ອນຂໍ້ມູນ | A1-A2 | |
ຊ່ວງແຮງດັນ | AC 230V / DC24V / AC / DC 12-240V | |
ການບໍລິໂພກພະລັງງານ | AC 3.5VA / DC 2.0W | |
ຄວາມທົນທານຕໍ່ແຮງດັນ | -15%~+10% | |
ຕົວຊີ້ວັດການສະຫນອງ | LED ສີຂຽວ | |
ຕົວຊີ້ບອກ Relay | LED ສີແດງ | |
ຊ່ວງເວລາ | 0.1s-100 ມື້ | |
ກໍານົດເວລາ | ປຸ່ມ | |
ການບິດເບືອນເວລາ | 0.1% | |
ເຮັດຊ້ໍາຄວາມຖືກຕ້ອງ | 0.5% | |
ຄ່າສໍາປະສິດອຸນຫະພູມ | 0.05%/°C, ທີ່ = 20°C (0.05%/°F, =-68°F) | |
ຜົນຜະລິດ | FCT18-Xd1 | FCT18-Xd2 |
ຕິດຕໍ່ພົວພັນ | 1*SPDT | 2*SPDT |
ອັນດັບປັດຈຸບັນ | 1*16A | 2*16A |
ຂໍ້ມູນຈໍາເພາະທົ່ວໄປ | ||
ຊີວິດກົນຈັກ | 1*107 | |
ຊີວິດໄຟຟ້າ | 1*105 | |
ອຸນຫະພູມສະພາບແວດລ້ອມ | -20 … +60°C / -40 … +85°F | |
ການຕິດຕັ້ງ | ລົດໄຟ DIN EN/IEC 60715 | |
ການຈັດອັນດັບ IP | IP20 | |
ຄວາມຍາວຂອງເສັ້ນດ່າງ | 7ມມ (0.28ນິ້ວ) | |
ລະດັບຄວາມສູງທີ່ຕິດຕັ້ງ | ≤2200ມ | |
ລະດັບມົນລະພິດ | 2 | |
ຂະໜາດສາຍສູງສຸດ | AWG13-20 0.4Nm | |
ຂະໜາດ | 90mm*18mm*64mm | |
ນ້ຳໜັກ | ປະມານ 90g | |
ມາດຕະຖານ | GB/T 14048.5, IEC60947-5-1, EN68112-1 |
ຄໍາຮ້ອງສະຫມັກ
The FCT18-Xd timer relay is ideal for a wide range of industrial and commercial applications where precise timing control is required:
- ອັດຕະໂນມັດອຸດສາຫະກໍາ: Conveyor systems, material handling equipment, packaging machinery
- ການຄວບຄຸມຂະບວນການ: Sequential operations, batch processing, mixing and blending cycles
- ລະບົບ HVAC: Fan control, ventilation cycling, temperature regulation
- ການຄວບຄຸມປັ໊ມ: Irrigation systems, water treatment, chemical dosing
- Machine Protection: Cool-down periods, delayed start after power interruption
- ການຄວບຄຸມແສງ: Sequential lighting, staircase lighting, display illumination
- ການຄວບຄຸມມໍເຕີ: Star-delta starting, acceleration/deceleration timing
- ການຄຸ້ມຄອງພະລັງງານ: Load shedding, peak demand control
- ການກໍ່ສ້າງອັດຕະໂນມັດ: Access control systems, security lighting
- Agricultural Systems: Irrigation scheduling, feed dispensing, climate control
ຂໍ້ແນະນຳການຕິດຕັ້ງ
For optimal performance and longevity of the FCT18-Xd timer relay, we recommend following these installation guidelines:
- Mount the device on a standard 35mm DIN rail in a clean, dry environment.
- Ensure adequate ventilation around the device to prevent overheating.
- Maintain an operating environment within the specified temperature range (-20°C to +60°C).
- Use appropriate wire sizes (AWG13-20) for the terminals and maintain the recommended stripping length of 7mm.
- Avoid installing near sources of strong electromagnetic interference.
- Ensure the input voltage falls within the specified tolerance range.
- When installing multiple relays, maintain adequate spacing between devices to allow for heat dissipation.
- Verify all connections are secure and properly tightened to the specified torque (0.4N·m).
- Label wiring connections for easy identification during maintenance.
- Consider using surge protection devices when operating in environments with electrical noise or power fluctuations.
ຂໍ້ມູນມິຕິ
The FCT18-Xd features a compact design optimized for efficient use of panel space:
- ຄວາມສູງ: 90mm
- ກວ້າງ: 18mm
- ຄວາມເລິກ: 64mm
- Weight: Approximately 90g
ການປະຕິບັດຕາມແລະການຢັ້ງຢືນ
The FCT18-Xd timer relay is manufactured to comply with the following international standards:
- GB/T 14048.5
- IEC60947-5-1
- EN68112-1
These certifications ensure the device meets stringent requirements for safety, reliability, and electromagnetic compatibility in industrial environments.
Why Choose the VIOX FCT18-Xd?
The FCT18-Xd represents the culmination of years of engineering expertise in industrial timing control. Here’s why this asymmetrical timer relay stands out from the competition:
- ຄວາມຄ່ອງແຄ້ວພິເສດ: With its wide time range and adjustable ratio settings, the FCT18-Xd can replace multiple specialized timers in your inventory.
- Superior Reliability: Engineered with robust components and protective features, the FCT18-Xd delivers consistent performance even in harsh industrial environments.
- Installation Simplicity: Clear wiring diagrams, straightforward setup, and intuitive controls reduce commissioning time and minimize the potential for errors.
- ປະສິດທິພາບອາວະກາດ: The compact 18mm width design maximizes panel space utilization without compromising on functionality or performance.
- ຄວາມເຂົ້າກັນໄດ້ທົ່ວໄປ: With both NPN and PNP control signal options and a wide supply voltage range, the FCT18-Xd integrates seamlessly with virtually any control system.
- Cost Effectiveness: By combining multiple timing functions in a single device with exceptional durability, the FCT18-Xd offers outstanding value and reduces total ownership costs.
ສະຫຼຸບ
The VIOX FCT18-Xd asymmetrical on-delay and off-delay timer relay with control signal represents a sophisticated yet user-friendly solution for applications requiring precise timing control. With its extensive range of timing options, dual-function capability, and robust design, this versatile device delivers exceptional performance across a wide spectrum of industrial and commercial applications.
Whether you’re designing a new system or upgrading existing equipment, the FCT18-Xd offers the flexibility, reliability, and ease of use that modern automation demands. Contact our technical support team today to learn how the FCT18-Xd can enhance your timing control applications.