VIOX VSP1-D20/3(S) Pluggable Multi-Pole SPD
VIOX VSP1-D20/3(S) Pluggable Multi-Pole SPD αααααααΌαααΆαααΆαααΆαααΆαααΎαα‘αΎαααααΉαααΆααααααΆαααααααα ααα αΆαααα α§ααααα Class II/Type 2 αααααΆαααΆααααα L-PE αα·α N-PE ααΆαα½αααΉα 10kA nominal αα·α 20kA α αααααααα’αα·ααααΆα αααααΆαααΆαα» MOV ααΆαααααααα ααΆααααΎαααΆαααΈ 120V αα 400V AC ααΆαα½αααΉααααααααΆααααΎααα < 25nsα ααΆααα ααΆαααα’αΆα αααααΆαααΆααΆααΌαααΆαααα‘αΎαααΆααααα½ααα ααΎααααΌαααα DIN 35mm α α’αα»αααααΆα IEC 61643-11: 2011 αα·α EN 61643-11: 2012 ααΆαααααααΌαααααα·αααΆαααΆαααα»αααΈ 0.6kV ααα 1.8kV α ααΆαα½αααΉαααΆαααΆαααΆα IP20 ααΆαααΆαααΆαααααα αα·αααααΆααααααααΈα ααααΆαααΆαααααΎα SPD αααα’αΆα ααααΎααααΆααααΆααααααΆαααααΉαααΆαααα‘αΎαα’αααα·αααΈαααααα ααααα½ααααα αΌαααααΆααΌαααΆαααΏααΆαα αα·αααααΎαααΆααα αααα»ααααα ααααΌα ααΆααααα½αααααΎαααααΆααααΆααααααΉαααΆαααΆαααΆαααααααααααΆααααα α»ααααααα
ααααΎαααααΌαααΆαααααα’ααα ααΎαααΉαααααααααααααΆααα’ααααααα»ααααααα 12 ααααα
- ααΌααααααα +8618066396588
- Whatsappα+α¨α¦α‘α¨α α¦α¦α£α©α¦α₯α¨α¨
- Email:[email protected]
VIOX VSP1-D20/3(S) Pluggable Multi-Pole SPD
αα·αααααΆαααΌαα
VIOX VSP1-D20/3(S) ααΊααΆα§ααααα Pluggable Multi-Pole Surge Protective Protective Device (SPD) αααααΆαααααα·αααααΆαααααα αααααααΌαααΆααα ααΆα‘αΎααααααΆααααααΎααααΆαααα αααα»ααααααα ααα αΆαααα α§ααααααααα’αΆα ααααΎααααΆααααΆαααααααααααΌαααΆαααΆαααΆαααααΉαααΆααααααΆααααΆαααααα L-PE αα·α N-PE αααααααΎα±ααααΆααααΆαααΆαααααααααΆαααααα’αααααΆααααΆαααα‘αΎαα’αααα·αααΈααααααα
ααααααααααΆααα
- ααααΆαα II, ααααΆαα III, αααααα 2, αααααα 3 α§ααααα
- ααΈααΆααααααΆαααααΎααααΆααα αααα»αααααΉααααΆα ααα αΆααα
- ααααααΆαααΆαα L-PE, N-PE
- ααΆαααΆααααααααΆαααΎαα‘αΎα: αααα»α = 10 kA (8/20 ΞΌs)
- αααααα IEC/EN/ULα ααααΆαα II / αααααα 2 / αααααα 1CA
- ααΆαα»ααΆαααΆαα ααΆαααααααα MOV
- αααα ααααΆαα ααΆααα ααΆαααα’αΆα αααααΆαα
- ααΆαα’αα»αααααΆαα IEC 61643-11:2011, EN 61643-11:2012
αααααααα αα ααααα
| IEC α’αααα·αααΈ | 150 | 275 | 320 | 385 | 440 |
|---|---|---|---|---|---|
| ααα»α AC ααααα (50/60Hz) | 120 α | 230 α | 230 α | 230 α | α€α α ααΈ |
| ααα»αααααα·ααααα·ααΆαααααα’αα·ααααΆ (AC) | 150 α | 275V | 320 α | α£α¨α₯ α | α€α€α α |
| α ααααααααααααΆααααααα (8/20 ΞΌs) | 10 kA | 10 kA | 10 kA | 10 kA | 10 kA |
| α αααααααα’αα·ααααΆ (8/20 ΞΌs) | 20 kA | 20 kA | 20 kA | 20 kA | 20 kA |
| ααααα·αααΆαααΆαααα»α | 0.6 kV | 1.3 kV | 1.5 kV | 1.5 kV | 1.8 kV |
| ααααΎααααααααααΆ | < 25 α | ||||
| Fuse ααααα»α (α’αα·ααααΆ) | 125 A gL / gG | ||||
| ααΆαααΆααααααα ααααααααΈ (AC) | 10 kA | ||||
| TOV αααααα α₯ α | 180V | 335V | 335V | 335V | 580V |
| TOV 120 ααΆααΈα | 230V | 440V | 440V | 440V | 765V |
| αααα | αααΌααααΆα | αα»ααααα·ααΆααααΆααα | αα»ααααα·ααΆααααΆααα | αα»ααααα·ααΆααααΆααα | αα»ααααα·ααΆααααΆααα |
αααααααα αα ααααα αα·αααα·ααααΆα
- αα½αααΈαα»ααα ααΆαααααα·ααααα·ααΆαα -40Β°F ααα +158Β°F [-40Β°C to +70Β°C]
- ααααΎαααααα·ααααα·ααΆααααα’αΆα α’αα»ααααΆαααΆαα 5%β¦95%
- αααααΆαααα·ααΆααΆα αα·αααααααααα 80k Pa β¦ 106k Pa / -500 mβ¦.2000 m
- αααααΆααααααα·αααααααΈαα 39.9 lbf.in [4.5 Nm]
- αααααααααααΆααααααα (α’αα·ααααΆ): 2 AWG (ααΉα, αααα) / 4 AWG (α’αΆα ααααααααΆα)
- 35 mmΒ² (ααΉα, ααΆαα) / 25 mmΒ² (α’αΆα ααααααααΆα)
- ααΆααααα: 35 mm DIN Rail, EN 60715
- αααα·αααΆαααΆαα IP 20 (ααααΆααααααΆαα½α)
- αααααΆααααααΎααααΆαααααα»αααααα Thermoplastic: Extinguishing Degree UL 94 V-0
- ααΆαααΆαααΆαααααα α ααΆα
- ααααΆαααΆαααααα·ααααα·ααΆα / ααΆαα ααα’α»ααααα αΆαααα α»αα ααααααααααα / αα·ααΆαααΆααααα α
αααααααα·ααααααααα
- ααααΆααααααααΈα ααααΆα (RC)α ααΆαααααΎα
- RC Switching Capacity: AC: 250V / 0.5 A; DC: 250V / 0.1 A; 125V / 0.2 A; 75V / 0.5 A
- RC Conductor Cross Section (α’αα·ααααΆ): 16 AWG (ααΉα) / 1.5 mmΒ² (ααΉα)