VIOX VSP1-D20/1(S) +1 Pluggable Single-Pole SPD

VIOX VSP1-D20/1(S)+1 Pluggable Single-Pole SPD offers comprehensive surge protection for sub-distribution boards. This Class II+III/Type 2+3 device safeguards L-N and N-PE modes with 10kA nominal and 20kA maximum discharge current. Featuring high-energy MOV and GDT elements, it operates from 60V to 400V AC with <25ns response time for L-N and <100ns for N-PE. IEC 61643-11:2011 and EN 61643-11:2012 compliant, it provides voltage protection levels from 0.2kV to 1.8kV. With IP20 protection, thermal safeguards, and optional remote contacts, this versatile SPD suits various electrical installations, combining reliability and performance for enhanced power system protection in diverse applications.

ផ្ញើតម្រូវការរបស់អ្នក យើងនឹងដកស្រង់សម្រាប់អ្នកក្នុងរយៈពេល 12 ម៉ោង។

VIOX VSP1-D20/1(S) +1 Pluggable Single-Pole SPD

ទិដ្ឋភាពទូទៅ

The VIOX VSP1-D20/1(S)+1 is a high-performance Pluggable Single-Pole Surge Protective Device (SPD) designed for use in sub-distribution boards. This versatile device offers robust protection for L-N and N-PE modes, making it an ideal solution for various electrical installations.

លក្ខណៈសំខាន់ៗ

  • ថ្នាក់ II, ថ្នាក់ III, ប្រភេទ 2, ប្រភេទ 3 ឧបករណ៍
  • ទីតាំងនៃការប្រើប្រាស់៖ ក្រុមប្រឹក្សាចែកចាយរង
  • Mode of Protection: L-N, N-PE
  • ការវាយតម្លៃការកើនឡើង: ក្នុង = 10 kA (8/20 μs)
  • ប្រភេទ IEC/EN/UL៖ ថ្នាក់ II+III / ប្រភេទ 2+3
  • Protective Elements: High Energy MOV and GDT
  • លំនៅដ្ឋាន៖ ការរចនាដែលអាចដោតបាន។
  • ការអនុលោមតាម៖ IEC 61643-11:2011, EN 61643-11:2012

លក្ខណៈបច្ចេកទេស

IEC អគ្គិសនី 75 150 275 320 385 440
វ៉ុល AC ឈ្មោះ (50/60Hz) 60 វ 120 វ 230 វ 230 វ 230 វ ៤០០ វី
Maximum Continuous Operating Voltage (AC) (L-N) ៧៥ វ 150 វ 275V 320 វ ៣៨៥ វ ៤៤០ វ
Maximum Continuous Operating Voltage (AC) (N-PE) 255V
Nominal Discharge Current (8/20 μs) (L-N) / (N-PE) 10kV / 10kA
Maximum Discharge Current (8/20 μs) (L-N) / (N-PE) 20 kA / 20 kA
Voltage Protection Level (L-N) / (N-PE) 0.2kV/1.5kV 0.6kV/1.5kV 1.3kV/1.5kV 1.5kV/1.5kV 1.5kV/1.5kV 1.8kV/1.5kV
Follow Current Interrupt Rating (N-PE) 100Arms
Response Time (L-N) / (N-PE) < 25 ns / < 100 ns
Fuse បម្រុង (អតិបរមា) 125 A gL / gG
Short-Circuit Current Rating (AC) (L-N) 10 kA
TOV Withstand 5s (L-N) 90V 180V 335V 335V 335V 580V
TOV 120min (L-N) 115V 230V 440V 440V 440V 765V
របៀប ស៊ូទ្រាំ ស៊ូទ្រាំ សុវត្ថិភាពបរាជ័យ សុវត្ថិភាពបរាជ័យ សុវត្ថិភាពបរាជ័យ សុវត្ថិភាពបរាជ័យ
TOV Withstand 200ms (N-PE) 1200V

លក្ខណៈបច្ចេកទេស និងបរិស្ថាន

  • ជួរសីតុណ្ហភាពប្រតិបត្តិការ៖ -40°F ដល់ +158°F [-40°C to +70°C]
  • សំណើមប្រតិបត្តិការដែលអាចអនុញ្ញាតបាន៖ 5%…95%
  • សម្ពាធបរិយាកាស និងរយៈកំពស់៖ 80k Pa … 106k Pa / -500 m….2000 m
  • កម្លាំងបង្វិលរបស់វីសៈ 39.9 lbf.in [4.5 Nm]
  • ផ្នែកឆ្លងកាត់ផ្នែក (អតិបរមា): 2 AWG (រឹង, ខ្សែ) / 4 AWG (អាចបត់បែនបាន)
  • 35 mm² (រឹង, ជាប់) / 25 mm² (អាចបត់បែនបាន)
  • ការម៉ោន: 35 mm DIN Rail, EN 60715
  • កំរិតការពារ៖ IP 20 (ភ្ជាប់មកជាមួយ)
  • សម្ភារៈប្រើប្រាស់ក្នុងផ្ទះ៖ Thermoplastic: Extinguishing Degree UL 94 V-0
  • ការការពារកម្ដៅ៖ បាទ
  • ស្ថានភាពប្រតិបត្តិការ / ការចង្អុលបង្ហាញកំហុស៖ បៃតងយល់ព្រម / ពិការភាពក្រហម

លក្ខណៈពិសេសបន្ថែម

  • ទំនាក់ទំនងពីចម្ងាយ (RC)៖ ជាជម្រើស
  • RC Switching Capacity: AC: 250V / 0.5 A; DC: 250V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A
  • RC Conductor Cross Section (អតិបរមា): 16 AWG (រឹង) / 1.5 mm² (រឹង)