VIOX VL16-40 AC ប្រភេទ 1P + N RCBO

VIOX VL16-40 AC Type 1P+N RCBO offers comprehensive protection for household and commercial distribution systems. This IEC/EN61009-1 compliant device safeguards against earth faults, short-circuits, and overloads with a 10kA rated short-circuit capacity. Available in 1A to 40A ratings, it operates at 240V AC, 50/60Hz, with residual current options of 30mA, 100mA, or 300mA. Featuring B, C, or D tripping curves and instantaneous tripping ≤0.1s, it provides efficient protection against insulation failures and direct human contact. With easy DIN rail mounting and 4000 cycle electro-mechanical endurance, this versatile RCBO ensures reliable electrical safety for various applications.

ផ្ញើតម្រូវការរបស់អ្នក យើងនឹងដកស្រង់សម្រាប់អ្នកក្នុងរយៈពេល 12 ម៉ោង។

VIOX VL16-40 AC Type 1P+N Residual Current Circuit Breaker with Overcurrent Protection RCBO

ទិដ្ឋភាពទូទៅ

The VIOX VL16-40 RCBO provides comprehensive protection for household and commercial distribution systems. It offers protection against earth fault/leakage current, short-circuit, overload, and functions as an isolation device. This device effectively safeguards electric equipment against insulating failure and provides complementary protection against direct contact by human body.

លក្ខណៈសំខាន់ៗ

  • ស្តង់ដារ៖ IEC / EN61009-1
  • Type: Electro-magnetic type
  • Residual current characteristics: AC A
  • បង្គោលលេខ៖ 1P+N
  • ផ្លូវកោង៖ B, C, D
  • Rated short-circuit capacity: 10kA
  • Rated current (A): 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A
  • វ៉ុលដែលបានវាយតម្លៃ: 240V AC
  • ប្រេកង់ដែលបានវាយតម្លៃ៖ 50/60Hz
  • វាយតម្លៃចរន្តប្រតិបត្តិការសំណល់ (mA): 0.03, 0.1, 0.3
  • Tripping duration: instantaneous≤0.1s
  • ការស៊ូទ្រាំអគ្គិសនី - មេកានិច: 4000 វដ្ត

លក្ខណៈបច្ចេកទេស

  • Connection terminal: pillar terminal with clamp
  • Connection capacity: Rigid conductor 16mm²
  • Terminal connection height: 21.5mm
  • Installation: On symmetrical DIN rail 35mm or Panel mounting

ផ្ទុកលើសទម្ងន់លក្ខណៈការពារបច្ចុប្បន្ន

Test procedure ប្រភេទ សាកល្បងបច្ចុប្បន្ន រដ្ឋដំបូង Tripping or Non-tripping Time Limit Expected Result ចំណាំ
B,C,D 1.13 អ៊ិន cold t≥1 ម៉ោង។ No tripping
1.45 អ៊ិន after test a t<1h tripping Current in the 5s in the increase of stability
2.55 អ៊ិន្ឈ៍ cold 1s<t<60s tripping


3 អ៊ិន
5 អ៊ិន
10 អ៊ិន
cold t≥0.1s No tripping Turn on the auxiliary switch to close the current
អ៊ី

5 អ៊ិន
10 អ៊ិន
20 អ៊ិន
cold t<0.1s tripping Turn on the auxiliary switch to close the current

The terminology “cold state” refers to that no load is carried before testing at the reference setting temperature.

Residual Current Action Breaking Time

ប្រភេទ In/A I△n/A Residual Current (I△) Is Corresponding To The Following Breaking Time (S)
AC type any value any value ក្នុង 2In 5 អ៊ិន 5A,10A,20A,50A,100A,200A,500A
A type any value >0.01 1.4In 2.8In 7In
0.3 0.15 0.04 0.04 Max Break-time
The general type RCBO whose current IΔn is 0.03mA or less can use 0.25A instead of 5IΔn.

ខ្សែកោងលក្ខណៈ

ដ្យាក្រាមខ្សែភ្លើង

ផលិតផលដែលពាក់ព័ន្ធ

សួររកសម្រង់ឥឡូវនេះ

សួររកសម្រង់ឥឡូវនេះ