BDM-3 ααααααΆααααααΆαααΆαα’ααααΆαααααΎα
- αααααΆααα αααα α·α, ααΈααααααα α·α, SS304, SS316
- αααααΆααααααΆααααΆααα αα αααΌαααΈααΈαα»α, ααΈα’αΌααααΈα, ααα ααα‘α»α, PA6
- ααααΆααααΆαααΆαααααΎαα V0 (UL94)
- ααΆαααααΎααααΆααα αααααααα»ααααα·ααΆααααααααα·ααΈα§ααααΆα ααααααΎαα‘αΎα
- αα»αααΆαα αααααααΌααα»ααααα·ααΆα αα·ααα»αααΆαααΆαααΆαααΌααΈααΎαα‘αΎα
- ααααΏααααααΆαααααααααΆαα αααΆαααΈαααααααααΈα‘α»α ααααΆααα αΆαααα (αααα ααΈαααααααα‘αΆα NPT)
- ααααΏαααααααααααα α α·αααα ααααΆααααααΈ, αααα PVC, αααΆαααΈααααααα Serrated, α§αααααααΆααααααααα α, αααΆαααΆαα» AB Putty
- ααΆαααααΌαααΆαααααα αααααΎαααααΌαααΆαααααα’αΆα ααααΆαααΆαααΆαααααΎαα»α
ααααΎαααααΌαααΆαααααα’ααα ααΎαααΉαααααααααααααΆααα’ααααααα»ααααααα 12 ααααα
- ααΌααααααα +8618066396588
- Whatsappα+α¨α¦α‘α¨α α¦α¦α£α©α¦α₯α¨α¨
- Email:[email protected]
VIOX BDM-3 αααΆααααΆαααΆαααΆααααα αΆαααααα½αααααααααΉαααΆααααα»α
αα·αααααΆαααΌαα
αααααααΆαααα VIOX BDM-3 αααα’αΆα ααΆαααΆαααΆααααα»αααΆααααα½αααααΊ Gland ααααΌαααΆααα ααΆα‘αΎααααααΆααααΆααααα αΌααααααααααΆααα»ααααα·ααΆα αα·αα’αΆα αα»αα α·αααααΆααα αααα»αααααααααααααααΆααα αααααααααααααααΊαααααααααααΆααααα·ααααΆααααααΆααα»ααααα·ααΆαααΎαα‘αΎα (Ex e) αααααΌαααΆαααΆαααΆαααΆααααα»α (Ex d) αα·ααααααΌαααΆαααΆαααΆαααΌααΈ (Ex t)α ααΆααααΌαααΆαααα·αα ααααΈααααα»ααΆαα»ααΎααααααΆααα»αααΆααααααααΌα ααΆαααα α·α ααΈααααααα α·α SS304 αα·α SS316 αααααΆααΆααΆαααΌαααΆααααααΉαααΆα corrosion αα·αααΆαααΆαααΉαααααΆαα·α ααααα’α ααα·ααααααααααΌαααΆααααααΆααααα IECEx, ATEX, EAC (CUTR) αα·α CNEx ααααααααααΆααααααααΆα IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-31 αα·α IEC/EN 60529α
ααααααααααΆααα
- αααααΆααααααΎααααΆααααΆαααΌαα ααΆααα αααα»ααααα α·ααααα α·αααΈααα-plated, SS304, αα·α SS316 αααααΆαααααααΆααααααααα·αααΆααααα
- αααααΉαα’αΆααΆαααΆαα»α αααααααΌαααΆαααΆαααΆαααααα’αααααΆααααΉααααααΆααα·ααααΆαααΌα ααΆααΉα ααΌααΈ αα·αααΆαααΆαα»ααΈααΈα
- ααΆαααΆαααΆααααααα ααΆαααααα IP66 αα·α IP68 (1m, 1h) αααααΆααααααΎαααΆαααΆαααΆαααΉα αα·αααΌααΈααΆαααα’α
- αα½αααΈαα»ααα ααΆαααααΌααΆαα ααααΎαααΆαααααααααααααα·αααααΆααα αααα»αααΈαα»ααα ααΆαααΈ -20 βαα +60 βαα·α -60 βαα +80 βα
- ααΆαβααααΎβααααΆααβα αααα»αβ: αααααα·αααααααΆααααααααααααααααΆαα αα½αααΆα αααααα‘ αααααα’ αααααα’α‘ αα·ααααααα’α’α
- ααΆαα’αα»αααα IECEx, ATEX, EAC (CUTR) αα·α CNEx ααΆααααααΆααα
- ααΆαααααΌαααΆαααααα αααααΎαααααΌαααΆαααααα’αΆα ααααΆαααΆαααΆαααααΎαα»αα
αααααααα αα ααααα
| ααΆαα» | ααααααΆααααα’α·α |
|---|---|
| αααααα | ααααααααΆαααααααα αΆαααααα½α |
| ααΈαα»ααα ααΆαααααα·ααααα·ααΆα | ααΈ -20 βαα +60 β / -60 βαα +80 β |
| α’ααΈααααΆα | α’ααΈα db IIC Gb; Ex eb IIC Gb; Ex tb IIIC Db |
| ααΆαααΆαααΆαααΆαα αΌα | IP66, IP68 (1m, 1h) |
| αααααΆαα | αααα α·α, ααΈααααααα α·α, SS304, SS316 |
| αααααα·ααΈ | ααααααααααααααΆαα (ααααα 1 ααααα 2 ααααα 21 ααααα 22) |
| αα·ααααΆαααααα | IECEx, ATEX, EAC (CUTR), CNEx |
| αααααααΆα | IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-31, IEC/EN 60529 |
αα·αααααααα αα ααααα
SH-BDM-3 ααααααααααααΆα
| ααα α | αααααααα‘αΆα AG | ααααααΆααααα»α α | αα½αααΆαααα | ααααααΆααααα α | ααα αα’αα·ααααΆ D | L1 | α’α·α | |
|---|---|---|---|---|---|---|---|---|
| 16 | M16X1.5 | 3/8 | 7 | 0.3 | 1 | 5.5~12 | 29 | 70 |
| 20 α | M20X1.5 | 1/2 | 11 | 0.3 | 1 | 9.5~16 | 29 | 70 |
| 20C | M20X1.5 | 1/2 | 15 | 0.3 | 1 | 12.5~20.5 | 37 | 73 |
| α’α₯ α | M25X1.5 | 3/4 | 15 | 0.3 | 1 | 12.5~20.5 | 37 | 73 |
| α’α₯ α | M25X1.5 | 3/4 | 20 | 0.4 | 1.2 | 17~26 | 44 | 79 |
| α£α’ α | M32X1.5 | 1 | 20 | 0.4 | 1.2 | 17~26 | 44 | 79 |
| α£α’ α | M32X1.5 | 1 | 27 | 0.4 | 1.4 | 22~33 | 55 | 84 |
| α€α α | M40X1.5 | 1-1/4 | 27 | 0.6 | 1.9 | 22~33 | 55 | 86 |
| 40C | M40X1.5 | 1-1/4 | 34 | 0.6 | 2.2 | 28~41 | 67 | 95 |
| 50 αααΈ | M50X1.5 | 1-1/2 | 34 | 0.8 | 2.3 | 28~41 | 67 | 110 |
| 50C | M50X1.5 | 1-1/2 | 43 | 0.9 | 2.4 | 36~52.6 | 73 | 110 |
| α¦α£ α | M63X1.5 | 2 | 43 | 0.9 | 2.4 | 36~52.6 | 73 | 110 |
| 63 α | M63X1.5 | 2 | 55 | 0.9 | 2.4 | 46~65 | 89 | 117 |
| α§α₯ α | M75X1.5 | 2-1/2 | 55 | 0.9 | 2.4 | 46~65 | 89 | 117 |
| 75C | M75X1.5 | 2-1/2 | 65 | 0.9 | 2.8 | 57~78 | 116 | 125 |
| 90 α | M90X1.5 | 3 | 65 | 0.9 | 2.8 | 57~78 | 116 | 125 |
| 90C | M90X1.5 | / | 75 | 0.9 | 2.8 | 68~88 | 130 | 130 |
αααααα·ααΈ
αααααααΆαααα VIOX BDM-3 ααΆαααΆαααΆααααα»ααααα½αααααααΊααα’αααααΆααααααΎαα αααα»αααααααααααααααΆαααααααΆαααΆαααΆααααα αΌααααααααααΆααα»ααααα·ααΆα αα·αα’αΆα αα»αα α·αααααΆαα ααΆαααααα·αααααααΆααααα·ααααΆαααααααααααΉαααααααααααα’αΆααααα αα½αααΆααααΈαα»ααα ααΆαααααα ααΆαααΆαα»ααΈααΈ αα·αααΆαααΆαααΉαααααΆαα·α α ααΆααα ααΆααααΉαααΆα αα·αααααΎαααΆααααα’αΆα αα»αα α·αααααΆαααααΎα±ααααΆαααααα·αααααααΆααααΆααααα·ααΆααΆαααΆαα·ααααααα αα·αα§ααααΆα αααα αα½αααΆααααααααΆαααα (ααααααΆαααααααααααα½α 'W', ααααααα ααααα 'X', ααααααΆαααα 'Z'), ααααα’αα‘αΆααααΌααΊ αα·αααααα’ααΈααΌα‘ααααααΆαααα·α αα·αααΆαα·ααααααααΆαααααααααααΆααααααΆααααΆααααα»αααΆααα»αα ααααααα’αΆα ααααΌαααΆαααααΎαα αααα»αααα·ααααΆα Ex e & Ex t αα·ααα αααα»αα§ααααα Ex d αα αααααααΎααΆαα½ααααΆαααΆαα» putty α
αα·αααααααα αα ααααα
- αααααΆααα αααα α·α, ααΈααααααα α·α, SS304, SS316
- αααααΆααααααΆααααΆααα αα αααΌαααΈααΈαα»α, ααΈα’αΌααααΈα, ααα ααα‘α»α, PA6
- ααααΆααααΆαααΆαααααΎαα V0 (UL94)
- ααΆαααααΎααααΆααα αααααααα»ααααα·ααΆααααααααα·ααΈα§ααααΆα ααααααΎαα‘αΎα
- αα»αααΆαα αααααααΌααα»ααααα·ααΆα αα·ααα»αααΆαααΆαααΆαααΌααΈααΎαα‘αΎα
- ααααΏααααααΆαααααααααΆαα αααΆαααΈαααααααααΈα‘α»α ααααΆααα αΆαααα (αααα ααΈαααααααα‘αΆα NPT)
- ααααΏαααααααααααα α α·αααα ααααΆααααααΈ, αααα PVC, αααΆαααΈααααααα Serrated, α§αααααααΆααααααααα α, αααΆαααΆαα» AB Putty
- ααΆαααααΌαααΆαααααα αααααΎαααααΌαααΆαααααα’αΆα ααααΆαααΆαααΆαααααΎαα»α