Ikhtisar
VOSA4-PK-1500V VIOX AC1250V DC1000V Dual-Rated Semiconductor Protection Fuse: aR class, 315A-1400A, 200kA breaking at AC1250V and 100kA at DC1000V (≤15ms), CE marked to IEC 60269-4 and GB/T 13539.4. For rail, storage and charging converters.
Protection projects usually run two fuse families, one for the AC side and one for the DC side, which doubles the stocking decisions, the drawings and the qualification work. The AC1250V DC1000V Dual-Rated Semiconductor Protection Fuse from VIOX Electric removes that duplication: a single aR-class design covering 315A to 1400A for IGBT modules, thyristors and rectifier diodes in rail traction, renewable power stations, telecom rooms, metallurgy plants, charging piles and utility converters.
Fitur
- Rated voltage 1250VDC and current capacity 315A for ess & semiconductor high-speed fuse applications.
- High interrupting performance (200kA) with rapid current-limiting fault clearing.
- Engineered and tested in accordance with GB/T 13539.4 / GB/T13539.4 / IEC 60269-4 standards.
- Precision-engineered low-power-loss silver-plated contacts and high-temperature ceramic or flame-retardant housing.
- Direct OEM replacement geometry for standardized industrial, solar PV, ESS, and EV protection panels.
Spesifikasi
VOSA4-PK-1500V Technical Specifications
| Nomor seri | Rated Current A | Pre-arcing I²t A²s | Melting I²t A²s | Power dissipation W |
| 1 | 315 | 9600 | 55000 | 83 |
| 2 | 350 | 14100 | 81000 | 88 |
| 3 | 400 | 19000 | 109000 | 94 |
| 4 | 450 | 31400 | 174000 | 98 |
| 5 | 500 | 41000 | 221000 | 102 |
| 6 | 550 | 54900 | 311000 | 108 |
| 7 | 630 | 84000 | 480000 | 115 |
| 8 | 700 | 118000 | 679000 | 118 |
| 9 | 800 | 210000 | 980000 | 122 |
| 10 | 900 | 307000 | 1390000 | 130 |
| 11 | 1000 | 456000 | 2010000 | 135 |
| 12 | 1100 | 579000 | 2660000 | 138 |
| 13 | 1250 | 805900 | 3949000 | 145 |
| 14 | 1400 | 1249000 | 5970000 | 150 |
VOSA4-PK-1500V Ratings & Dimensions Table 2
| Rated Current (A) | Conventional Time (h) | Conventional Current | |
| “gR” | |||
| Inf | lf | ||
| ln≤63 | 1 | 1.13ln | 1.6ln |
| 63<In≤160 | 2 | ||
| 160<ln≤400 | 3 | ||
| 400<ln | 4 | ||
| Note:ln is the rated current of the fuse; lnf is the conventional non-fusing current; if is the conventional fusing current. | |||
Selection & Installation Notes
- Verify system maximum voltage (1250VDC) and prospective short-circuit fault current before selecting the fuse link or holder rating.
- Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
- Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
- Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.
PERTANYAAN YANG SERING DIAJUKAN
What voltage and current ratings does the VIOX VOSA4-PK-1500V AC1250V DC1000V Dual-Rated Semiconductor Protection Fuse support?
This VIOX VOSA4-PK-1500V series is rated for 1250VDC with a current rating of 315A and 200kA breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.
Which international standards apply to VIOX VOSA4-PK-1500V AC1250V DC1000V Dual-Rated Semiconductor Protection Fuse?
The VOSA4-PK-1500V series is designed and verified to GB/T 13539.4 / GB/T13539.4 / IEC 60269-4 requirements for safe overcurrent and short-circuit protection.
Where is the VIOX VOSA4-PK-1500V AC1250V DC1000V Dual-Rated Semiconductor Protection Fuse typically installed?
It is engineered for ess & semiconductor high-speed fuse circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.
Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?
Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.