VIOX ELECTRIC
Nyelv

VIOX RT18-63 500VAC 63A 14×51mm Cylindrical HRC Fuse Link

RT18-63 RT18-500VAC 63A 14×51mm Cylindrical HRC Fuse Link is specifically designed to cover a wide range of protection for general industrial applications, which include gG/gL, aM and aR. This cylindrical shape fuse link with a 14×51mm standardized size was made in a compact.

VIOX sorozat
RT18-63
Névleges feszültség
500VAC
Névleges áram
63A
Szabvány
IEC60269-1 / IEC60269-2

Áttekintés

RT18-63 RT18-500VAC 63A 14×51mm Cylindrical HRC Fuse Link is specifically designed to cover a wide range of protection for general industrial applications, which include gG/gL, aM and aR. This cylindrical shape fuse link with a 14×51mm standardized size was made in a compact configuration and can save more space. RT18-63 14×51mm Fuse Link is available in multiple ampere ratings from 2A to 63A, which helps match specific requirements in various industrial applications, such as LV-net works, solid state relays, cable protection and so on.

Jellemzők

  • IEC60269-1
  • IEC60269-2
  • Rated voltage 500VAC and current capacity 63A for low-voltage hrc industrial fuse applications.
  • High interrupting performance (High Breaking Capacity) with rapid current-limiting fault clearing.
  • Engineered and tested in accordance with IEC60269-1 / IEC60269-2 standards.
  • Precision-engineered low-power-loss silver-plated contacts and high-temperature ceramic or flame-retardant housing.

Műszaki adatok

RT18-63 Technical Specifications

Model/Size Rated Voltage (V) RatedCurrent (A) OverallDjmension
Φ C A Fig.
10.3x38T 380/500 2,4,6,8,10,12,16,20,25,32 10.3 38T Fig.1
5×20 250 0.5,1,2,4,6,10,12,13 5 20 Fig.2
5×25 250 0.5,1,2,4,6,10,12,16 5 25
6×20 250 0.5,1,2,4,6,10,12,16 6 20
6.3×23 250 0.5,1,2,4,6,10,12,16,20 6.3 23
6.3×25 250 0.5,1,2,4,6,10,12,16,20 6.3 25
6.3 x31.5 250/500 0.5,1,2,4,6,10,12,16,20 6.3 31.5
8.5×23 250 0.5,1,2,4,6,10,12,16,20,25 8.5 23
8.5 x31.5 250/500 0.5,1,2,4,6,10,12,16,20,25 8.5 31.5
8.5 x36 380/500 2,4,6,8,10,12,16,20,25,32 8.5 36
10×30 380/500 2,4,6,8,10,12,16,20,25,32 10 30
10.3×28.5 250 2,4,6,8,10,12,16,20,25,32 10.3 28.5
10.3×31.5 250/500 2,4,6,8,10,12,16,20,25,32 10.3 31.5
10.3×34 250/500 2,4,6,8,10,12,16,20,25,32 10.3 34
10.3×38 380/500 2,4,6,8,10,12,16,20,25,32 10.3 38
10.3×57 690 2,4,6,8,10,12,16,20,25,32 10.3 57
14.3×38 250/500 2,4,6,8,10,12,16,20,25,32,40,50,63 14.3 38
14.3×45 380/500 2,4,6,8,10,12,16,20,25,32,40,50,63 14.3 45
14.3×51 380/500 2,4,6,8,10,12,16,20,25,32,40,50,63 14.3 51
14.3×67 690 2,4,6,8,10,12,16,20,25,32,40,50 14.3 67
15×50 380/500 20,25,32,40,50 15 50
16.7×35 250/500 16,20,25,32,40,50,63 16.7 35
18×37 250/500 2,4,6,8,10,12,16,20,25,32,40,50,63 18 37
18×50 690 2,4,6,8,10,12,16,20,25,32,40,50,63 18 50
20.5×40 250/500 2,4,6,8,10,12,16,20,25,32,40,50,63 20.5 40
20.5×76 690 2,4,6,8,10,12,16,20,25,32,40,50,63 20.5 76
20.5×114 690 2,4,6,8,10,12,16,20,25,32,40,50,63 20.5 114
20.5×127 690 0.5,1,2,4,6,8,10,12,16,20,25,32 20.5 127
22.2×58 380/500 10,16,20,25,32,40,50,63,80,100,125 22.2 58
27×60 690 32,40,50,63,80 27 60
27×139 690 32,40,50,63 27 139
27×147 690 32,40,50,63 27 147
30×57 690 16,20,25,32,40,50,63,80,100,125 30 57
14.3x51H 380/500 2,4,6,8,10,12,16,20,25,32,40,50,63 14.3 51H Fig.3
20.5 x76H 690 2,4,6,8,10,12,16,20,25,32,40,50,63 20.5 76H
20.5x114H 690 2,4,6,8,10,12,16,20,25,32,40,50,63 20.5 114H
20.5x 127H 690 0.5,1,2,4,6,8,10,12,16,20,25,32 20.5 127H
22.2 x58H 690 10,16,20,25,32,40,50,63,80,100,125 22.2 58H
27x 139H 690 32,40,50,63 27 139H
27x 147H 690 32,40,50,63 27 147H

Selection & Installation Notes

  • Verify system maximum voltage (500VAC) and prospective short-circuit fault current before selecting the fuse link or holder rating.
  • Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
  • Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
  • Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.

GYIK

What voltage and current ratings does the VIOX RT18-63 500VAC 63A 14×51mm Cylindrical HRC Fuse Link support?

This VIOX RT18-63 series is rated for 500VAC with a current rating of 63A and High Breaking Capacity breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.

Which international standards apply to VIOX RT18-63 500VAC 63A 14×51mm Cylindrical HRC Fuse Link?

The RT18-63 series is designed and verified to IEC60269-1 / IEC60269-2 requirements for safe overcurrent and short-circuit protection.

Where is the VIOX RT18-63 500VAC 63A 14×51mm Cylindrical HRC Fuse Link typically installed?

It is engineered for low-voltage hrc industrial fuse circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.

Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?

Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.

Termékajánlatot kérne?
Építsük fel együtt.

Küldje el nekünk a termékmodelljét, a műszaki jellemzőket, a mennyiséget és az OEM-követelményeket. Csapatunk áttekinti az alkalmazást, és egy munkanapon belül válaszol.

Kérjen Árajánlatot