RT18L-125 RT18L-500VAC 125A 22×58mm Cylindrical HRC Fuse Link is specifically designed to cover a wide range of protection for general industrial applications, which include gG/gL, aM and aR. This cylindrical shape fuse link with a 22×58mm standardized size was made in a compact configuration and can save more space. RT18L-125 22×58mm Fuse Link is available in multiple ampere ratings from 10A to 125A, which helps match specific requirements in various industrial applications, such as motors, transformers, low voltage distribution, control circuits and so on.
500VAC 125A 22×58mm Cylindrical HRC Fuse Link
Jellemzők
- IEC60269-1
- IEC60269-2
- Rated voltage 500VAC and current capacity 125A for low-voltage hrc industrial fuse applications.
- High interrupting performance (High Breaking Capacity) with rapid current-limiting fault clearing.
- Engineered and tested in accordance with IEC60269-1 / IEC60269-2 standards.
- Precision-engineered low-power-loss silver-plated contacts and high-temperature ceramic or flame-retardant housing.
Műszaki adatok
RT18L-125 Technical Specifications
| Model/Size | Névleges feszültség (V) | RatedCurrent (A) | OverallDimension | ||
|---|---|---|---|---|---|
| Φ C | A | Fig. | |||
| 10.3x38T | 380/500 | 2,4,6,8,10,12,16,20,25,32 | 10.3 | 38T | Fig.1 |
| 5×20 | 250 | 0.5,1,2,4,6,10,12,13 | 5 | 20 | Fig.2 |
| 5×25 | 250 | 0.5,1,2,4,6,10,12,16 | 5 | 25 | |
| 6×20 | 250 | 0.5,1,2,4,6,10,12,16 | 6 | 20 | |
| 6.3×23 | 250 | 0.5,1,2,4,6,10,12,16,20 | 6.3 | 23 | |
| 6.3×25 | 250 | 0.5,1,2,4,6,10,12,16,20 | 6.3 | 25 | |
| 6.3 x31.5 | 250/500 | 0.5,1,2,4,6,10,12,16,20 | 6.3 | 31.5 | |
| 8.5×23 | 250 | 0.5,1,2,4,6,10,12,16,20,25 | 8.5 | 23 | |
| 8.5 x31.5 | 250/500 | 0.5,1,2,4,6,10,12,16,20,25 | 8.5 | 31.5 | |
| 8.5 x36 | 380/500 | 2,4,6,8,10,12,16,20,25,32 | 8.5 | 36 | |
| 10×30 | 380/500 | 2,4,6,8,10,12,16,20,25,32 | 10 | 30 | |
| 10.3×28.5 | 250 | 2,4,6,8,10,12,16,20,25,32 | 10.3 | 28.5 | |
| 10.3×31.5 | 250/500 | 2,4,6,8,10,12,16,20,25,32 | 10.3 | 31.5 | |
| 10.3×34 | 250/500 | 2,4,6,8,10,12,16,20,25,32 | 10.3 | 34 | |
| 10.3×38 | 380/500 | 2,4,6,8,10,12,16,20,25,32 | 10.3 | 38 | |
| 10.3×57 | 690 | 2,4,6,8,10,12,16,20,25,32 | 10.3 | 57 | |
| 14.3×38 | 250/500 | 2,4,6,8,10,12,16,20,25,32,40,50,63 | 14.3 | 38 | |
| 14.3×45 | 380/500 | 2,4,6,8,10,12,16,20,25,32,40,50,63 | 14.3 | 45 | |
| 14.3×51 | 380/500 | 2,4,6,8,10,12,16,20,25,32,40,50,63 | 14.3 | 51 | |
| 14.3×67 | 690 | 2,4,6,8,10,12,16,20,25,32,40,50 | 14.3 | 67 | |
| 15×50 | 380/500 | 20,25,32,40,50 | 15 | 50 | |
| 16.7×35 | 250/500 | 16,20,25,32,40,50,63 | 16.7 | 35 | |
| 18×37 | 250/500 | 2,4,6,8,10,12,16,20,25,32,40,50,63 | 18 | 37 | |
| 18×50 | 690 | 2,4,6,8,10,12,16,20,25,32,40,50,63 | 18 | 50 | |
| 20.5×40 | 250/500 | 2,4,6,8,10,12,16,20,25,32,40,50,63 | 20.5 | 40 | |
| 20.5×76 | 690 | 2,4,6,8,10,12,16,20,25,32,40,50,63 | 20.5 | 76 | |
| 20.5×114 | 690 | 2,4,6,8,10,12,16,20,25,32,40,50,63 | 20.5 | 114 | |
| 20.5×127 | 690 | 0.5,1,2,4,6,8,10,12,16,20,25,32 | 20.5 | 127 | |
| 22.2×58 | 380/500 | 10,16,20,25,32,40,50,63,80,100,125 | 22.2 | 58 | |
| 27×60 | 690 | 32,40,50,63,80 | 27 | 60 | |
| 27×139 | 690 | 32,40,50,63 | 27 | 139 | |
| 27×147 | 690 | 32,40,50,63 | 27 | 147 | |
| 30×57 | 690 | 16,20,25,32,40,50,63,80,100,125 | 30 | 57 | |
| 14.3x51H | 380/500 | 2,4,6,8,10,12,16,20,25,32,40,50,63 | 14.3 | 51H | Fig.3 |
| 20.5 x76H | 690 | 2,4,6,8,10,12,16,20,25,32,40,50,63 | 20.5 | 76H | |
| 20.5x114H | 690 | 2,4,6,8,10,12,16,20,25,32,40,50,63 | 20.5 | 114H | |
| 20.5x 127H | 690 | 0.5,1,2,4,6,8,10,12,16,20,25,32 | 20.5 | 127H | |
| 22.2 x58H | 690 | 10,16,20,25,32,40,50,63,80,100,125 | 22.2 | 58H | |
| 27x 139H | 690 | 32,40,50,63 | 27 | 139H | |
| 27x 147H | 690 | 32,40,50,63 | 27 | 147H | |
Selection & Installation Notes
- Verify system maximum voltage (500VAC) and prospective short-circuit fault current before selecting the fuse link or holder rating.
- Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
- Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
- Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.
GYIK
What voltage and current ratings does the VIOX RT18L-125 500VAC 125A 22×58mm Cylindrical HRC Fuse Link support?
This VIOX RT18L-125 series is rated for 500VAC with a current rating of 125A and High Breaking Capacity breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.
Which international standards apply to VIOX RT18L-125 500VAC 125A 22×58mm Cylindrical HRC Fuse Link?
The RT18L-125 series is designed and verified to IEC60269-1 / IEC60269-2 requirements for safe overcurrent and short-circuit protection.
Where is the VIOX RT18L-125 500VAC 125A 22×58mm Cylindrical HRC Fuse Link typically installed?
It is engineered for low-voltage hrc industrial fuse circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.
Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?
Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.