ماژول تکی RCBO مدل VIOX VRO1-40 با قطر ۱۸ میلیمتر
VIOX VRO1-40 RCBO offers comprehensive protection in a compact 18mm single module design. This IEC/EN 61009-1 compliant device features a 6kA breaking capacity and supports currents up to 40A at 240V AC. With adjustable sensitivity from 10mA to 500mA, it provides AC and A type protection against residual currents, overloads, and short circuits. The RCBO offers B and C tripping curves, IP20 protection, and operates from -25°C to +40°C. Key advantages include 1P+N configuration, versatile terminal connections, and 4,000 electrical/10,000 mechanical life cycles. Ideal for residential, commercial, and industrial applications, this RCBO ensures reliable protection with easy DIN rail mounting and plug-in connection. Its high fire-resistant casing and automatic fault disconnection make it a safe choice for various electrical installations.
الزامات خود را ارسال کنید، ما ظرف 12 ساعت برای شما نقل قول خواهیم کرد
- تلفن: +8618066396588
- واتساپ: +8618066396588
- ایمیل: sales@viox.com
VIOX VRO1-40 18mm Single Module RCBO 6KA 1P+N B&C Curve
نمای کلی
The VIOX VRO1-40 is a compact Residual Current Circuit Breaker with Overload protection (RCBO) designed for electrical safety in residential, commercial, and industrial applications. This single module device offers comprehensive protection against leakage currents up to 30mA, as well as overloads and short circuits.
ویژگیهای کلیدی
- Compact 18mm single module design
- 1P+N configuration
- 6KA breaking capacity
- B and C curve options
- Automatic circuit disconnection upon fault detection
- AC and A type protection options
- Compliant with IEC61009/EN61009 standards
مشخصات فنی
- Standard: IEC/EN 61009-1, ESV Compliant 61009-1
- Type: Electro-magnetic type, electronic type
- Rated voltage: 240V(230V)~
- Rated current: 6A, 8A, 10A, 13A, 16A, 20A, 25A, 32A, 40A
- حساسیت نامی (I△n): 0.01، 0.03، 0.1، 0.3، 0.5 آمپر
- Insulation voltage (Ui): 500V
- Rated residual making and breaking capacity (I△m): 630A
- Short-circuit current (I△c): 6000A
- SCPD fuse: 6000A
- فرکانس نامی: ۵۰/۶۰ هرتز
- درجه آلودگی: ۲
ویژگیهای مکانیکی
- عمر الکتریکی: ۴۰۰۰ بار کارکرد
- عمر مکانیکی: 10000 عملیات
- Breaking capacity: 6000A
- درجه حفاظت: IP20
- Ambient temperature: -25~+40℃ (daily average ≤35℃)
- Storage temperature: -25~+70℃
نصب
- Terminal connection type: Cable/Pin-type busbar/U type busbar
- Terminal size for cable: 16mm² (AWG 18-3)
- Terminal size for busbar: 16mm² (AWG 18-3)
- Tightening torque: 1.2N*m (22 In-lbs)
- Mounting: On DIN rail 35mm by means of fast clip device
- Connection: Plug-in type
کاربردها
- تاسیسات برق مسکونی
- ساختمانهای اداری
- Commercial spaces
- کاربردهای صنعتی
ویژگیهای ایمنی
- Protection against leakage currents
- محافظت در برابر اضافه بار و اتصال کوتاه
- پیشگیری از خطر آتش سوزی
- High fire-resistant and shockproof plastic casing