رله تایمر تاخیر در روشن شدن VIOX FCT18-A/At با سیگنال کنترل فعال شونده
The VIOX FCT18-A/At Power On-Delay Relay offers precise timing control for industrial applications. Features an extensive time range (0.1s – 100 days) with <0.5% error, retrigger control signal (NPN/PNP), and DIN rail mounting. Ideal for motor starting, lighting control, and cyclic switching.
الزامات خود را ارسال کنید، ما ظرف 12 ساعت برای شما نقل قول خواهیم کرد
- تلفن: +8618066396588
- واتساپ: +8618066396588
- ایمیل: sales@viox.com
Precision Timing Control for Industrial Applications
The VIOX FCT18-A/At is an advanced power on-delay timer relay designed to provide reliable, precise timing control for a wide range of industrial applications. Featuring exceptional accuracy, versatile configuration options, and robust construction, this timer relay is the ideal solution for automated systems requiring dependable time-delayed switching operations.
بررسی اجمالی محصول
The FCT18-A/At power on-delay timer relay is engineered to deliver consistent performance in demanding industrial environments. With time ranges spanning from 0.1 seconds to 100 days and a time error of less than 0.5%, this relay provides the precision timing control required for critical industrial processes. The relay’s retrigger control signal functionality offers enhanced flexibility for complex timing sequences, making it suitable for a diverse range of applications.
ویژگیها و مزایای کلیدی
- محدوده زمانی گسترده: Offering timing control from 0.1 seconds to 100 days, providing flexibility for various application requirements
- دقت بالا: Time error less than 0.5% ensures precise operation for critical timing applications
- منبع تغذیه چند منظوره: Wide power supply range from 12 to 240 VAC/DC, compatible with most industrial power systems
- تنظیمات کاربرپسند: Easy configuration with wiring diagrams printed on the side of the product
- Strong Anti-Interference Capability: Reliable operation even in environments with electrical noise and interference
- Visual Status Indication: Green LED for supply indication and red LED for relay status, allowing for quick visual verification
- نصب روی ریل DIN: Standard DIN rail mount (EN/IEC 60715) for easy installation in control panels
- طراحی جمع و جور: Space-saving dimensions of 90mm*18mm*64mm, ideal for high-density control panels
مشخصات فنی
FCT18-A/At Timer Relay Specifications | |||
---|---|---|---|
پارامتر | FCT18-A1 | FCT18-A2 | FCT18-At |
ترمینال ورودی | A1-A2 | ||
محدوده ولتاژ | برق متناوب ۲۳۰ ولت / برق مستقیم ۲۴ ولت / برق متناوب/مستقیم ۱۲-۲۴۰ ولت | ||
مصرف برق | برق متناوب ۳.۵ ولت آمپر / برق مستقیم ۲ وات | ||
تحمل ولتاژ | -15% ~ +10% | ||
نشانگر تأمین | چراغ سبز | ||
نشانگر رله | چراغ قرمز | ||
محدودههای زمانی | 0.1 ثانیه تا 100 روز | ||
تنظیم زمان | دکمه | ||
انحراف زمان | 0.1% | ||
دقت تکرار | 0.5% | ||
ضریب دما | 0.05%/°C, at≈20°C (0.05%/°F, ≈68°F) | ||
تماس خروجی | 1*SPDT | 2*SPDT | ۱*SPDT+۱*SPDT |
جریان نامی | 1*16 آمپر | 2 * 16 آمپر | |
عمر مکانیکی | ۱ * ۱۰⁷ | ||
عمر الکتریکی | ۱ * ۱۰⁵ | ||
دمای محیط | -20…+60°C/-40…+85°C | ||
نصب | ریل DIN EN/IEC 60715 | ||
رتبهبندی IP | آی پی ۲۰ | ||
طول سلب کردن | ۷ میلیمتر (۰.۲۸ اینچ) | ||
ارتفاع نصب شده | ≤2200 متر | ||
سطح آلودگی | 2 | ||
حداکثر اندازه کابل | AWG13-20 0.4Nm | ||
ابعاد | 90 میلیمتر * 18 میلیمتر * 64 میلیمتر | ||
وزن | حدود ۹۰ گرم | ||
استانداردها | GB/T 14048.5, IEC60947-5-1, EN61812-1 |
Timing Functions
The FCT18-A/At timer relay offers two primary timing functions designed to meet diverse application requirements:
ON-Delay (A Function)
When power (Un) is applied, the timing cycle (T) begins. After the preset time has elapsed, the output relay (R) changes state. This function is ideal for applications requiring a delay before equipment activation.
ON-Delay + Instantaneous (At Function)
This enhanced function combines the standard ON-delay operation with an instantaneous output. When power (Un) is applied, one output contact (11-14/R1) changes state immediately, while the other output contact (21-24/R2) changes state after the preset time (T) has elapsed. This dual-output functionality is perfect for applications requiring both immediate and delayed responses.
Time and Ratio Setting Options
The FCT18-A/At timer relay provides extensive configuration options to accommodate a wide variety of timing requirements:
Time Range Settings
- ۰.۱-۱ ثانیه: برای کاربردهای چرخه سریع که نیاز به زمانبندی دقیق کوتاهمدت دارند
- ۱-۱۰ ثانیه: ایدهآل برای فرآیندهای صنعتی استاندارد با چرخه کوتاه
- 0.1-1 متر: مناسب برای کنترل فرآیند مبتنی بر دقیقه
- ۱-۱۰ متر: مناسب برای چرخههای فرآیند طولانیتر
- ۰.۱-۱ ساعت: برای کاربردهای چرخه ساعتی
- ۱-۱۰ ساعت: کنترل زمانبندی طولانی مدت مبتنی بر ساعت
- 0.1-1 روز: کنترل چرخه روزانه برای فرآیندهای طولانی
- ۱-۱۰ روز: زمانبندی چند روزه برای فرآیندهای طولانی مدت
- ۳-۳۰ روز: درخواستهای ماهانه
- ۱۰-۱۰۰ روز: زمانبندی طولانیتر برای کاربردهای فصلی
Ratio Settings
Fine-tune your timing operations with 20 ratio settings ranging from 10% to 100% in 5% increments, allowing for precise adjustment within each time range.
گزینههای سیمکشی
The FCT18-A/At supports both NPN and PNP control signal configurations:
پیکربندی NPN
Connects with negative logic control signals, where the control signal pulls to ground. Suitable for integration with NPN transistor outputs or sinking PLC outputs.
پیکربندی PNP
Works with positive logic control signals, where the control signal provides a positive voltage. Compatible with PNP transistor outputs or sourcing PLC outputs.
ابعاد
کاربردها
Timer relays like the FCT18-A/At provide simple, reliable, and economical control solutions for various industrial applications. They deliver time-delayed switching capabilities essential for starting motors, controlling loads, or managing processes.
Industrial Uses
کنترل روشنایی
Enable delayed switching of multiple rows of lamps in production facilities or greenhouses. The precise timing control allows for energy-efficient illumination scheduling and extends lamp life through controlled switching.
Star-Delta Motor Starting
Reduce starting current with changeover delay to prevent interphase short-circuits. The reliable timing ensures proper motor startup sequence, protecting expensive equipment from current surges.
Cyclic Switching of Machinery
Implement weekly startup of fans to prevent sticking or flush pipes to keep them clear. The programmable timing cycles maintain equipment in optimal operating condition through regular automated movement.
کاربردهای اضافی
- Control Panels: Integrate timing functions into centralized control systems
- Pump Controls: Manage pump cycling for water management and process applications
- Machine Tools: Control sequential operations in manufacturing equipment
- Automatic Doors: Regulate opening and closing cycles for security and efficiency
- Car Park Barriers: Manage vehicle access with timed barrier operations
- Assembly Machines: Coordinate production line timing for optimal throughput
- Compressor Controls: Regulate compression cycles to maintain system pressure
- حمل و نقل: Time-based control of transportation system components
- Industrial Refrigeration: Manage defrost cycles and cooling operations
- Packaging Machines: Synchronize packaging operations for consistent product output
- Baking Ovens: Control heating cycles for consistent product quality
- Water and Wastewater: Manage treatment process timing and pump operations
- Wind Power: Control timing for safety and operational systems
- Industrial Cleaning Processes: Schedule cleaning cycles for optimal performance
ویژگیهای نظارت و حفاظت
The FCT18-A/At timer relay is part of a comprehensive range of industrial relays designed to monitor and detect operating conditions. When integrated with monitoring relays, the FCT18-A/At can be part of a complete system that provides:
Three-Phase Voltage Monitoring
- نظارت بر ولتاژ تجهیزات سه فاز سیار
- حفاظت از پرسنل و تاسیسات در برابر تغییر فاز
- Monitoring of the supply voltage of machines and installations
- Protection of equipment against damage caused by unstable supply voltage
- Switching to emergency or auxiliary supply
Single-Phase Current Monitoring
- نظارت بر مصرف جریان موتور
- نظارت بر تأسیسات روشنایی و مدارهای گرمایشی
- نظارت بر اضافه بار تجهیزات حمل و نقل
- نظارت بر دستگاههای قفلکننده، چرخدندههای ترمز الکترومکانیکی و روتورهای قفلشده
Single-Phase Voltage Monitoring
- مانیتورینگ سرعت موتورهای جریان مستقیم
- نظارت بر ولتاژ باتری و سایر شبکههای تأمین
نظارت بر سطح مایع
- محافظت از پمپها در برابر خشک کار کردن
- محافظت در برابر سرریز شدن ظرف
- کنترل سطح مایعات
- تشخیص نشتیها
- کنترل نسبتهای اختلاط
دستورالعملهای نصب
For optimal performance and reliability of your FCT18-A/At timer relay, follow these installation guidelines:
- نصب روی ریل DIN: Secure the relay to a standard 35mm DIN rail in accordance with EN/IEC 60715.
- ملاحظات زیستمحیطی: Install in environments within the specified temperature range (-20°C to +60°C operational, -40°C to +85°C storage).
- سیم کشی: Use appropriate wire size (AWG13-20) and ensure proper stripping length (7mm) for secure connections.
- Control Signal Configuration: Configure for either NPN or PNP operation according to your control system requirements.
- Time and Ratio Setting: Set the desired time range and ratio using the front panel controls before system startup.
- Clearance: Allow adequate space around the relay for ventilation and heat dissipation.
- حفاظت: Install in a control panel or enclosure providing at least IP20 protection.
Why Choose VIOX FCT18-A/At Timer Relay?
The VIOX FCT18-A/At power on-delay timer relay stands out as the ideal choice for industrial timing applications due to its exceptional combination of features:
- Precision and Reliability: With a time error less than 0.5% and a repeat accuracy of 0.5%, the FCT18-A/At delivers consistent, dependable performance for critical timing applications.
- تطبیق پذیری: The extensive time range from 0.1 seconds to 100 days, combined with 20 ratio settings, provides unmatched flexibility to meet diverse application requirements.
- Ease of Use: Simple configuration with wiring diagrams on the product and clear LED status indicators ensures straightforward setup and operation.
- دوام: With a mechanical life of 10 million operations and an electrical life of 100,000 operations, the FCT18-A/At offers exceptional longevity and value.
- انطباق با استانداردها: Manufactured in accordance with GB/T 14048.5, IEC60947-5-1, and EN61812-1 standards, ensuring quality and compatibility.
- طراحی جمع و جور: The space-saving dimensions (90mm*18mm*64mm) make it ideal for installation in crowded control panels.
نتیجهگیری
The VIOX FCT18-A/At power on-delay timer relay represents the perfect balance of precision, versatility, and reliability for industrial timing applications. From simple motor starting sequences to complex process control timing, this compact yet powerful relay delivers consistent performance in demanding environments. With its extensive configuration options, robust construction, and standards-compliant design, the FCT18-A/At is the ideal timing control solution for modern industrial automation systems.
For more information about the VIOX FCT18-A/At power on-delay timer relay or to discuss your specific application requirements, please contact our technical support team. We’re committed to helping you find the perfect timing solution for your industrial control needs.