VIOX ELECTRIC
Wika

VIOX CJX2s High-Current AC Contactor

Three-pole high-current contactors for AC motor starting and
control.

  • 120–800 A AC-3 at 380/400 V, depending on model
  • 55–450 kW motor ratings at 380/400 V
  • 1000 V rated insulation voltage
  • Dual-coil control and 2NO + 2NC auxiliary contacts

Pangkalahatang-ideya

VIOX CJX2s high-current AC contactors are designed for frequent AC
motor starting, control and remote circuit switching. The model range
listed below covers 120–800 A AC-3 at 380/400 V, with three main poles
and a rated insulation voltage of 1000 V. Suitable thermal overload
relays can be combined with the contactors to form motor starters.

Mga tampok

  • Dual-coil control circuit with separate pull-in and holding
    characteristics.
  • Bottom drawer-type coil construction for maintenance access.
  • Standard 2NO + 2NC auxiliary contacts.
  • Rail or screw mounting, with model-specific installation
    dimensions.
  • Optional front dust cover and arc barriers for applicable
    mga configuration.

Teknikal na Pagtutukoy

Modelo AC-3 na kuryente sa 380/400 V AC-3 na lakas ng motor sa 380/400 V AC-3 current at 660/690 V AC-3 motor power at 660/690 V
CJX2s-120 120 A 55 kW 86 A 80 kW
CJX2s-160 160 A 75 kW 107 A 100 kW
CJX2s-185 185 A 90 kW 107 A 100 kW
CJX2s-225 225 A 110 kW 118 A 110 kW
CJX2s-265 265 A 132 kW 170 A 160 kW
CJX2s-330 330 A 160 kW 235 A 200 kW
CJX2s-400 400 A 200 kW 303 A 300 kW
CJX2s-500 500 A 250 kW 353 A 335 kW
CJX2s-630 630 A 335 kW 400 A 350 kW
CJX2s-800 800 A 450 kW 470 A 375 kW
Parameter Pagtutukoy
Main poles 3P
Na-rate na boltahe ng pagkakabukod Ui 1000 V
Rated operating voltage Ue in the rating table 380/400 V; 660/690 V
Mga pantulong na contact 2NO + 2NC
Rated AC coil voltage options 110 V, 127 V, 220/230 V, 380/400 V
Coil frequency options 50 Hz; 50/60 Hz
Proteksyon ng enclosure IP00
Mga tinukoy na pamantayan GB/T 14048.1 / IEC 60947-1; GB/T 14048.4 / IEC 60947-4-1

Select the contactor by the motor voltage, utilization category and
model-specific rating. Coil supply voltage is a separate selection from
main-circuit operating voltage. The contactor is used with appropriate
motor and circuit protection.

Dimensyon

Match the frame size and fitted accessories to the installation
drawing. Dimensions for CJX2s-120–160 and CJX2s-185–800 are shown
separately.

CJX2s high-current contactor installation dimension drawings

Impormasyon sa Pag-order

For a quotation, provide the model, motor voltage and power, coil
voltage and frequency, overload-relay and accessory requirements, and
quantity.

Kailangan ng Product Quote?
Buuin Natin Ito nang Magkasama.

Ipadala sa amin ang modelo ng produkto, mga teknikal na rating, dami, at mga kinakailangan ng OEM. Susuriin ng aming koponan ang iyong aplikasyon at tutugon sa loob ng isang araw ng negosyo.

Humiling ng Quote