VIOX FCT18-A/At Power On-Delay timer Relay dengan Isyarat Kawalan Pencetus Semula
The VIOX FCT18-A/At Power On-Delay Relay offers precise timing control for industrial applications. Features an extensive time range (0.1s – 100 days) with <0.5% error, retrigger control signal (NPN/PNP), and DIN rail mounting. Ideal for motor starting, lighting control, and cyclic switching.
Hantar keperluan anda, kami akan sebut harga untuk anda dalam masa 12 jam
- TEL:+8618066396588
- Sila+8618066396588
- Email:[email protected]
Precision Timing Control for Industrial Applications
The VIOX FCT18-A/At is an advanced power on-delay timer relay designed to provide reliable, precise timing control for a wide range of industrial applications. Featuring exceptional accuracy, versatile configuration options, and robust construction, this timer relay is the ideal solution for automated systems requiring dependable time-delayed switching operations.
Gambaran Keseluruhan Produk
The FCT18-A/At power on-delay timer relay is engineered to deliver consistent performance in demanding industrial environments. With time ranges spanning from 0.1 seconds to 100 days and a time error of less than 0.5%, this relay provides the precision timing control required for critical industrial processes. The relay’s retrigger control signal functionality offers enhanced flexibility for complex timing sequences, making it suitable for a diverse range of applications.
Ciri dan Faedah Utama
- Julat Masa yang Luas: Offering timing control from 0.1 seconds to 100 days, providing flexibility for various application requirements
- Ketepatan Tinggi: Time error less than 0.5% ensures precise operation for critical timing applications
- Bekalan Kuasa Serbaguna: Wide power supply range from 12 to 240 VAC/DC, compatible with most industrial power systems
- Persediaan Mesra Pengguna: Easy configuration with wiring diagrams printed on the side of the product
- Strong Anti-Interference Capability: Reliable operation even in environments with electrical noise and interference
- Petunjuk Status Visual: Green LED for supply indication and red LED for relay status, allowing for quick visual verification
- Pemasangan Rel DIN: Standard DIN rail mount (EN/IEC 60715) for easy installation in control panels
- Reka bentuk padat: Space-saving dimensions of 90mm*18mm*64mm, ideal for high-density control panels
Spesifikasi Teknikal
| FCT18-A/At Timer Relay Specifications | |||
|---|---|---|---|
| Parameter | FCT18-A1 | FCT18-A2 | FCT18-At |
| Terminal Input | A1-A2 | ||
| Julat voltan | AC 230V / DC24V / AC/DC 12-240V | ||
| Penggunaan kuasa | AC 3.5VA/ DC 2.0W | ||
| Toleransi voltan | -15% ~ +10% | ||
| Petunjuk bekalan | LED hijau | ||
| Petunjuk geganti | LED merah | ||
| Julat masa | 0.1s-100hari | ||
| Penetapan masa | butang | ||
| Sisihan masa | 0.1% | ||
| Ulang ketepatan | 0.5% | ||
| Pekali suhu | 0.05%/°C, pada≈20°C (0.05%/°F, ≈68°F) | ||
| Hubungan output | 1*SPDT | 2*SPDT | 1*SPDT+1*SPDT |
| Nilai semasa | 1*16A | 2*16A | |
| Kehidupan mekanikal | 1*10⁷ | ||
| Kehidupan elektrik | 1*10⁵ | ||
| Suhu Ambien | -20…+60°C/-40…+85°C | ||
| Melekap | DIN rel EN/IEC 60715 | ||
| Penarafan IP | IP20 | ||
| Panjang pelucutan | 7mm (0.28in) | ||
| Ketinggian yang dipasang | ≤2200m | ||
| Tahap pencemaran | 2 | ||
| Saiz kabel maksimum | AWG13-20 0.4Nm | ||
| Dimensi | 90mm*18mm*64mm | ||
| Berat badan | kira-kira 90g | ||
| Piawaian | GB/T 14048.5, IEC60947-5-1, EN61812-1 | ||
Timing Functions
The FCT18-A/At timer relay offers two primary timing functions designed to meet diverse application requirements:
ON-Delay (A Function)
When power (Un) is applied, the timing cycle (T) begins. After the preset time has elapsed, the output relay (R) changes state. This function is ideal for applications requiring a delay before equipment activation.
ON-Delay + Instantaneous (At Function)
This enhanced function combines the standard ON-delay operation with an instantaneous output. When power (Un) is applied, one output contact (11-14/R1) changes state immediately, while the other output contact (21-24/R2) changes state after the preset time (T) has elapsed. This dual-output functionality is perfect for applications requiring both immediate and delayed responses.
Time and Ratio Setting Options
The FCT18-A/At timer relay provides extensive configuration options to accommodate a wide variety of timing requirements:
Tetapan Julat Masa
- 0.1-1s: Untuk aplikasi kitaran pantas yang memerlukan pemasaan jangka pendek yang tepat
- 1-10s: Sesuai untuk proses industri kitaran pendek standard
- 0.1-1m: Sesuai untuk kawalan proses berasaskan minit
- 1-10m: Sesuai untuk kitaran proses yang lebih panjang
- 0.1-1jam: Untuk aplikasi kitaran setiap jam
- 1-10 jam: Kawalan masa berdasarkan jam lanjutan
- 0.1-1hari: Kawalan kitaran harian untuk proses lanjutan
- 1-10hari: Masa berbilang hari untuk proses jangka panjang
- 3-30hari: Aplikasi kitaran bulanan
- 10-100hari: Masa tempoh lanjutan untuk aplikasi bermusim
Tetapan Nisbah
Fine-tune your timing operations with 20 ratio settings ranging from 10% to 100% in 5% increments, allowing for precise adjustment within each time range.
Pilihan Pendawaian
The FCT18-A/At supports both NPN and PNP control signal configurations:
Konfigurasi NPN
Connects with negative logic control signals, where the control signal pulls to ground. Suitable for integration with NPN transistor outputs or sinking PLC outputs.
Konfigurasi PNP
Works with positive logic control signals, where the control signal provides a positive voltage. Compatible with PNP transistor outputs or sourcing PLC outputs.
Dimensi
Aplikasi
Timer relays like the FCT18-A/At provide simple, reliable, and economical control solutions for various industrial applications. They deliver time-delayed switching capabilities essential for starting motors, controlling loads, or managing processes.
Industrial Uses
Kawalan Pencahayaan
Enable delayed switching of multiple rows of lamps in production facilities or greenhouses. The precise timing control allows for energy-efficient illumination scheduling and extends lamp life through controlled switching.
Star-Delta Motor Starting
Reduce starting current with changeover delay to prevent interphase short-circuits. The reliable timing ensures proper motor startup sequence, protecting expensive equipment from current surges.
Cyclic Switching of Machinery
Implement weekly startup of fans to prevent sticking or flush pipes to keep them clear. The programmable timing cycles maintain equipment in optimal operating condition through regular automated movement.
Aplikasi Tambahan
- Panel Kawalan: Integrate timing functions into centralized control systems
- Pump Controls: Manage pump cycling for water management and process applications
- Alat Mesin: Control sequential operations in manufacturing equipment
- Automatic Doors: Regulate opening and closing cycles for security and efficiency
- Car Park Barriers: Manage vehicle access with timed barrier operations
- Assembly Machines: Coordinate production line timing for optimal throughput
- Compressor Controls: Regulate compression cycles to maintain system pressure
- Pengangkutan: Time-based control of transportation system components
- Industrial Refrigeration: Manage defrost cycles and cooling operations
- Packaging Machines: Synchronize packaging operations for consistent product output
- Baking Ovens: Control heating cycles for consistent product quality
- Water and Wastewater: Manage treatment process timing and pump operations
- Wind Power: Control timing for safety and operational systems
- Industrial Cleaning Processes: Schedule cleaning cycles for optimal performance
Ciri Pemantauan dan Perlindungan
The FCT18-A/At timer relay is part of a comprehensive range of industrial relays designed to monitor and detect operating conditions. When integrated with monitoring relays, the FCT18-A/At can be part of a complete system that provides:
Three-Phase Voltage Monitoring
- Pemantauan voltan peralatan tiga fasa mudah alih
- Perlindungan kakitangan dan pemasangan terhadap pembalikan fasa
- Monitoring of the supply voltage of machines and installations
- Protection of equipment against damage caused by unstable supply voltage
- Switching to emergency or auxiliary supply
Single-Phase Current Monitoring
- Pemantauan penggunaan arus motor
- Pemantauan pemasangan lampu dan litar pemanasan
- Pemantauan beban peralatan pengangkutan
- Pemantauan peranti pengunci, gear brek elektromekanikal, dan rotor terkunci
Single-Phase Voltage Monitoring
- Pemantauan kelajuan motor DC
- Pemantauan voltan bateri dan rangkaian bekalan lain
Pemantauan Tahap Cecair
- Perlindungan pam terhadap kering
- Perlindungan terhadap limpahan kontena
- Kawalan paras cecair
- Pengesanan kebocoran
- Kawalan nisbah campuran
Garis Panduan Pemasangan
For optimal performance and reliability of your FCT18-A/At timer relay, follow these installation guidelines:
- Pemasangan Rel DIN: Secure the relay to a standard 35mm DIN rail in accordance with EN/IEC 60715.
- Pertimbangan Alam Sekitar: Install in environments within the specified temperature range (-20°C to +60°C operational, -40°C to +85°C storage).
- Pendawaian: Use appropriate wire size (AWG13-20) and ensure proper stripping length (7mm) for secure connections.
- Control Signal Configuration: Configure for either NPN or PNP operation according to your control system requirements.
- Time and Ratio Setting: Set the desired time range and ratio using the front panel controls before system startup.
- Clearance: Allow adequate space around the relay for ventilation and heat dissipation.
- Perlindungan: Install in a control panel or enclosure providing at least IP20 protection.
Why Choose VIOX FCT18-A/At Timer Relay?
The VIOX FCT18-A/At power on-delay timer relay stands out as the ideal choice for industrial timing applications due to its exceptional combination of features:
- Precision and Reliability: With a time error less than 0.5% and a repeat accuracy of 0.5%, the FCT18-A/At delivers consistent, dependable performance for critical timing applications.
- serba boleh: The extensive time range from 0.1 seconds to 100 days, combined with 20 ratio settings, provides unmatched flexibility to meet diverse application requirements.
- Ease of Use: Simple configuration with wiring diagrams on the product and clear LED status indicators ensures straightforward setup and operation.
- Ketahanan: With a mechanical life of 10 million operations and an electrical life of 100,000 operations, the FCT18-A/At offers exceptional longevity and value.
- Pematuhan Standard: Manufactured in accordance with GB/T 14048.5, IEC60947-5-1, and EN61812-1 standards, ensuring quality and compatibility.
- Reka bentuk padat: The space-saving dimensions (90mm*18mm*64mm) make it ideal for installation in crowded control panels.
Kesimpulan
The VIOX FCT18-A/At power on-delay timer relay represents the perfect balance of precision, versatility, and reliability for industrial timing applications. From simple motor starting sequences to complex process control timing, this compact yet powerful relay delivers consistent performance in demanding environments. With its extensive configuration options, robust construction, and standards-compliant design, the FCT18-A/At is the ideal timing control solution for modern industrial automation systems.
For more information about the VIOX FCT18-A/At power on-delay timer relay or to discuss your specific application requirements, please contact our technical support team. We’re committed to helping you find the perfect timing solution for your industrial control needs.