Relè a tempo ASTP-Y

The VIOX ASTP-Y Analog Timer is a reliable and precise time delay relay designed for industrial automation systems and mechanical devices. This device counts down the set time and then switches the relay contacts, maintaining this position until reset. It features a time range of 0-60 seconds, adjustable via an analog dial, and is suitable for various applications requiring accurate timing control.

Inviate i vostri requisiti, vi faremo un preventivo entro 12 ore

VIOX ASTP-Y Analog Timer

Panoramica

The VIOX ASTP-Y Analog Timer is a reliable and precise time delay relay designed for industrial automation systems and mechanical devices. This device counts down the set time and then switches the relay contacts, maintaining this position until reset. It features a time range of 0-60 seconds, adjustable via an analog dial, and is suitable for various applications requiring accurate timing control.

Caratteristiche principali

  • Precise Timing Control: Adjustable time range from 0 to 60 seconds with an analog dial.
  • Reliable Operation: Switches relay contacts after the set time and maintains the position.
  • Dual Relay Outputs: Two relay outputs with a maximum load of 5A each.
  • Facile installazione: Includes PF083A base for DIN rail mounting.
  • Indicatori visivi: Front panel work indicator for easy monitoring.
  • Costruzione resistente: Designed for long-lasting performance with high mechanical and electrical life.
  • Ampio intervallo di tensione: Operates on 230 VAC with a tolerance of +/-10%.

Specifiche tecniche

CLASSIFICATION TIMER TIMER
MODELLO ASTP-N ASTP-Y AH2-N AH2-Y
APPEARANCE
DIMENSIONS 61H×49W×70D 88H×58W×68D 61H×49W×70D 88H×58W×68D
MOUNTING
& SOCKET

SURFACE(-N) PF083A(E) PS-08 PF083A(E) PS-08
FLUSH(-Y) US-08 P3G-08 US-08 P3G-08
FULL TIMING RANGE SEC:1,3,6,10,12,30,60
MIN:3,6,12,30,60
HR:3,6,12,24
SEC:1,3,6,12,30,60
MIN:3,6,12,30,60
HR:3,6,12,24
RATED VOLTAGE DC(V):12,24 AC(V):12,24,110,220,240, 50/60Hz DC(V):12,24 AC(V):12,24,110,220,240, 50/60Hz
INDICATOR OPERATING Time Operating ON-UP Two indicator Lamp ON-UP
CONTATTO MODELLO ASTP-N1/ ASTP-Y1 ASTP-N2/ ASTP-Y2 ASTP-N/ ASTP-Y AH2-N1/ AH2-Y1 AH2-N2/ AH2-Y2 AH2-N/ AH2-Y
TIME LIMIT 1C 5A 5A 5A 5A
TIME LIMIT 2C 5A 5A
INSTANTANEOUS 1C 5A 5A
LIFE MECHANICAL 5×10tempi 5×10tempi
ELECTRICAL 10tempi 10tempi
ACCURACY REPEAT ERROR ±1% max ±1% max
SETTING ERROR ±10% max ±10% max
VOLTAGE ERROR ±1% max ±1% max
TEMP. ERROR ±2% max ±2% max
RESET TIME 0.1 sec max 0.1 sec max
CONSUMED POWER 2VA 3VA
AMBIENT TEMPERATURE -10℃~+55℃ -10℃~+55℃
AMBIENT HUMIDITY 48~85%RH 48~85%RH
WEIGHT 220g 220g
CONNECTION DIAGRAMS & TIMING CHART 39A 39B 39C 39D 39E 39F

Applicazioni

The VIOX ASTP-Y Analog Timer is ideal for a variety of applications in industrial automation and mechanical devices. It is suitable for use in control panels, machinery, and other systems requiring precise timing control. The timer’s robust design and reliable performance make it an excellent choice for both commercial and industrial environments.

Technical Data

  • Alimentazione: 230 VAC +/-10%
  • Output: Relè
  • Max. Load: 5A
  • Intervallo di tempo: 0-60 seconds
  • Dimensioni: 40×50 mm
  • Assembly: DIN Rail, In the table
  • Risoluzione: Analog Dial
  • Degree of Protection: IP 40
  • Vita meccanica: 5×106 tempi
  • Vita elettrica: 105 tempi
  • Precisione: Repeat Error: ±1% Max., Setting Error: ±10% Max., Voltage Error: ±1% Max., Temp. Error: ±2% Max.
  • Reset Time: 0.1 Sec. Max.
  • Consumed Power: 2VA
  • Temperatura ambiente: -10℃ to +55℃
  • Ambient Humidity: 48% to 85% RH
  • Peso: 220g

Schema di collegamento

The VIOX ASTP-Y Analog Timer features a straightforward connection diagram for easy installation. The device starts counting the set time when the power supply voltage is applied, then switches the relay contacts and remains in this position. Relay A1 operates according to the set time on the panel, while Relay A2 operates according to the timer power supply.

Output Modes

When the power supply voltage is applied, the device starts counting the set time and then switches the relay contacts, maintaining this position. Relay A1 works according to the set time on the panel, and Relay A2 works according to the timer power supply. Below is the operation diagram:

 

Prodotti correlati

Richiedi subito un preventivo

Richiedi subito un preventivo