VIOX ELECTRIC
Nyelv

High-Speed Semiconductor, ESS & EV Fuse Manufacturer (VOSA 500V–2000V · up to 4000A / 250kA · VOEV 500V–750V DC · 51 SKUs)

Ultra-rapid aR/gR silver-element protection for IGBTs, VFDs, PCS inverters, utility BESS battery racks, traction rectifiers, and EV/EVSE DC fast-charging architectures—engineered for minimal clearing I²t.

51 High-Speed SKUs38 VOSA/VOGS/VOS + 13 VOEV EV
Up to 250 kA / 4000 A500V to 2000V DC ultra-rapid clearing
IEC 60269-4 · UL 248-13Drop-in 170M & Protistor® footprints
VIOX VOSA7-PK 1500V 4000A High-Speed Semiconductor and ESS Fuse
VIOX High-Speed Semiconductor & EV Fuses · 9 Series · 51 Live SKUs

Explore All VIOX High-Speed Semiconductor & EV Fuses Series

Click any ampere or voltage rating pill below to open its full IEC technical specification table and dimensional datasheet.

VIOX VOSA01 / VOSA1 Square-Body
ESS / Semiconductor · Size 01/1

VOSA01 / VOSA1 Square-Body

DIN blade (GK/HK) & flush-end (PK) semiconductor protection

Exact Part-Number Cross-Reference

High-Speed & EV Fuse Cross-Reference vs. Bussmann 170M, FWH & Mersen Protistor

Direct mechanical and IEC standard cross-reference for panel builders, EPCs, and distributors converting Tier-1 BOMs.

Footprint / Rating Tier Eaton Bussmann Mersen / Ferraz Siemens / Littelfuse VIOX Direct Equivalent
Square-Body Flush-End (PK, 690–1500V) Bussmann 170M Flush-End Mersen Protistor® Flush-End Siemens 3NE / Littelfuse PSR VIOX VOSA1-PK / VOSA2-PK / VOSA3-PK / VOSA4-PK / VOSA7-PK
Square-Body DIN Blade (GK/HK, 690–2000V) Bussmann 170M DIN 43653 Mersen Protistor® DIN Siemens 3NE DIN Blade VIOX VOSA000 / VOSA00 / VOSA1-GK / VOSA2-HK / VOSA4-GK
500V–750V DC BESS / ESS Battery Rack Bussmann 170M ESS / FWP Mersen Protistor® DC Littelfuse PSR DC VIOX VOSA00-CU (500V / 750V DC ESS)
North American Round & BS88 High-Speed Bussmann FWH / FWP / ET / FE Mersen A70QS / A70P / BS88 Littelfuse L70S / L70QS VIOX VOS92F–94FA (700V) / VOGS4–7 / RGS2
EV Automotive & EVSE Fast Charger Bussmann EV500 / EV750 Mersen MEV Series Littelfuse EV500 / EV750 VIOX VOEVu (500VDC 50–400A) & VOEVq (750VDC 50–1200A)
Engineering Confirmation: Verify total clearing I²t, breaking capacity, and project UL/IEC certification before substitution. Send your Tier-1 BOM list via the quote button below for rapid VIOX engineering cross-referencing.
Engineering Selection Rules

Key Specification & Safety Rules for High-Speed Semiconductor & EV Fuses

Field-proven sizing, derating, and safety practices to eliminate nuisance trips and thermal failures.

Coordinate Total Clearing I²t Strictly Below IGBT / Contactor Limits

Standard gG fuses clear too slowly for power electronics. Always verify that the VOSA fuse total clearing I²t at system voltage stays below the semiconductor or BESS contactor withstand curve.

Confirm Forced-Air & Busbar Cross-Section for High-Amp Flush-End Fuses

High-current VOSA3–VOSA7-PK fuses rely on busbar thermal conduction and cabinet airflow; apply torque and forced-air derating per datasheet.

Specify VOEVu (500V) / VOEVq (750V) for Cyclic EV & EVSE Thermal Loads

EV battery packs and DC fast chargers experience aggressive load cycling—VOEV elements are engineered to resist thermal fatigue while clearing high-energy DC faults.

High-Speed Semiconductor & EV Fuses Technical FAQ

Direct answers on standards, sizing, Tier-1 interchangeability, and factory OEM kitting.

aR vs gR What is the difference between aR and gR high-speed semiconductor fuses?

aR fuses are partial-range ultra-rapid fuses designed strictly for short-circuit protection of semiconductors (paired with thermal overload relays or electronic protection). gR fuses provide full-range overload plus ultra-rapid short-circuit protection.

250kA / 4000A Which VIOX fuse handles 1500V DC utility BESS or traction up to 4000 A?

The VIOX VOSA7-PK (1500V DC / 1250V AC, 1500 A–4000 A) and VOSA4-PK-1500V series deliver up to 250 kA breaking capacity per IEC 60269-4 and UL 248-13.

EV / EVSE How do VIOX VOEVu and VOEVq EV fuses differ?

VOEVu covers 500V DC across 8 ratings (50 A to 400 A) for EV battery modules, PDUs, and UPS systems. VOEVq covers 750V DC up to 1200 A (VOEVq-1200f) for high-voltage traction packs and DC fast-charging stations.

Kereszthivatkozás Can VIOX VOSA square-body fuses replace Bussmann 170M and Mersen Protistor?

Yes. VOSA000 through VOSA7-PK follow IEC 60269-4 and DIN 43653/flush-end mechanical footprints. Send your current 170M or Protistor part number and VIOX engineers will verify I²t and mounting dimensions.

Need High-Speed Semiconductor & EV Fuses Datasheets or BOM Cross-Ref?
Talk Directly with VIOX Engineers.

Send your rated voltage, ampere steps, breaking capacity, or Tier-1 part numbers for rapid factory pricing and evaluation samples.

Request High-Speed Semiconductor & EV Fuses Quote