High-Speed Semiconductor, ESS & EV Fuse Manufacturer (VOSA 500V–2000V · up to 4000A / 250kA · VOEV 500V–750V DC · 51 SKUs)
Ultra-rapid aR/gR silver-element protection for IGBTs, VFDs, PCS inverters, utility BESS battery racks, traction rectifiers, and EV/EVSE DC fast-charging architectures—engineered for minimal clearing I²t.
Explore All VIOX High-Speed Semiconductor & EV Fuses Series
Click any ampere or voltage rating pill below to open its full IEC technical specification table and dimensional datasheet.
VOSA7-PK 1500V 4000A High-Speed
Utility-scale BESS & rail traction 250 kA flush-end fuse
- Feszültség
- 1500 V DC / 1250 V AC
- Jelenlegi
- 1500–4000 A
- Szabvány
- IEC 60269-4 · UL 248-13
VOSA4 / VOSA5 Ultra-High-Power
1000V–2000V DC ultra-rapid fuses up to 250 kA breaking
- Feszültség
- 1000–2000 V DC
- Jelenlegi
- 315–2000 A
- Szabvány
- IEC 60269-4 · UL 248-13
VOSA3 Heavy-Duty High-Speed
690V–1500V flush-end & heavy-duty PCS semiconductor fuses
- Feszültség
- 690–1500 V AC/DC
- Jelenlegi
- 400–2000 A
- Szabvány
- IEC 60269-4 · aR
VOSA2 Square-Body High-Speed
High-current 690V–1500V inverter, rectifier & forced-air fuses
- Feszültség
- 690–1500 V AC/DC
- Jelenlegi
- 200–1000 A
- Szabvány
- IEC 60269-4 · aR
VOSA01 / VOSA1 Square-Body
DIN blade (GK/HK) & flush-end (PK) semiconductor protection
- Feszültség
- 690–1500 V AC/DC
- Jelenlegi
- 50–700 A
- Szabvány
- IEC 60269-4 · aR
VOSA000 / VOSA00 Square-Body
Compact 500V–1000V DC/AC ESS battery rack & VFD high-speed
- Feszültség
- 500–1000 V AC/DC
- Jelenlegi
- 20–315 A
- Szabvány
- IEC 60269-4 · aR/gR
VOS92F–94FA / VOGS4–7 / RGS2
North American round-body (700V) & BS88 bolted high-speed
- Feszültség
- 690–700 V AC/DC
- Jelenlegi
- 10–400 A
- Szabvány
- IEC 60269-4 · UL 248-13
VOEVu 500VDC Automotive Series
8 bolt-down EV battery module, PDU & UPS ratings (50A–400A)
VOEVq 750VDC High-Current Series
5 traction battery & DC fast-charging pile ratings (50A–1200A)
- Feszültség
- 750 V DC
- Jelenlegi
- 50–1200 A
- Szabvány
- EV / EVSE High-Breaking
High-Speed & EV Fuse Cross-Reference vs. Bussmann 170M, FWH & Mersen Protistor
Direct mechanical and IEC standard cross-reference for panel builders, EPCs, and distributors converting Tier-1 BOMs.
| Footprint / Rating Tier | Eaton Bussmann | Mersen / Ferraz | Siemens / Littelfuse | VIOX Direct Equivalent |
|---|---|---|---|---|
| Square-Body Flush-End (PK, 690–1500V) | Bussmann 170M Flush-End |
Mersen Protistor® Flush-End |
Siemens 3NE / Littelfuse PSR |
VIOX VOSA1-PK / VOSA2-PK / VOSA3-PK / VOSA4-PK / VOSA7-PK |
| Square-Body DIN Blade (GK/HK, 690–2000V) | Bussmann 170M DIN 43653 |
Mersen Protistor® DIN |
Siemens 3NE DIN Blade |
VIOX VOSA000 / VOSA00 / VOSA1-GK / VOSA2-HK / VOSA4-GK |
| 500V–750V DC BESS / ESS Battery Rack | Bussmann 170M ESS / FWP |
Mersen Protistor® DC |
Littelfuse PSR DC |
VIOX VOSA00-CU (500V / 750V DC ESS) |
| North American Round & BS88 High-Speed | Bussmann FWH / FWP / ET / FE |
Mersen A70QS / A70P / BS88 |
Littelfuse L70S / L70QS |
VIOX VOS92F–94FA (700V) / VOGS4–7 / RGS2 |
| EV Automotive & EVSE Fast Charger | Bussmann EV500 / EV750 |
Mersen MEV Series |
Littelfuse EV500 / EV750 |
VIOX VOEVu (500VDC 50–400A) & VOEVq (750VDC 50–1200A) |
I²t, breaking capacity, and project UL/IEC certification before substitution. Send your Tier-1 BOM list via the quote button below for rapid VIOX engineering cross-referencing.
Key Specification & Safety Rules for High-Speed Semiconductor & EV Fuses
Field-proven sizing, derating, and safety practices to eliminate nuisance trips and thermal failures.
Coordinate Total Clearing I²t Strictly Below IGBT / Contactor Limits
Standard gG fuses clear too slowly for power electronics. Always verify that the VOSA fuse total clearing I²t at system voltage stays below the semiconductor or BESS contactor withstand curve.
Confirm Forced-Air & Busbar Cross-Section for High-Amp Flush-End Fuses
High-current VOSA3–VOSA7-PK fuses rely on busbar thermal conduction and cabinet airflow; apply torque and forced-air derating per datasheet.
Specify VOEVu (500V) / VOEVq (750V) for Cyclic EV & EVSE Thermal Loads
EV battery packs and DC fast chargers experience aggressive load cycling—VOEV elements are engineered to resist thermal fatigue while clearing high-energy DC faults.
High-Speed Semiconductor & EV Fuses Technical FAQ
Direct answers on standards, sizing, Tier-1 interchangeability, and factory OEM kitting.
aR vs gR What is the difference between aR and gR high-speed semiconductor fuses?
aR fuses are partial-range ultra-rapid fuses designed strictly for short-circuit protection of semiconductors (paired with thermal overload relays or electronic protection). gR fuses provide full-range overload plus ultra-rapid short-circuit protection.
250kA / 4000A Which VIOX fuse handles 1500V DC utility BESS or traction up to 4000 A?
The VIOX VOSA7-PK (1500V DC / 1250V AC, 1500 A–4000 A) and VOSA4-PK-1500V series deliver up to 250 kA breaking capacity per IEC 60269-4 and UL 248-13.
EV / EVSE How do VIOX VOEVu and VOEVq EV fuses differ?
VOEVu covers 500V DC across 8 ratings (50 A to 400 A) for EV battery modules, PDUs, and UPS systems. VOEVq covers 750V DC up to 1200 A (VOEVq-1200f) for high-voltage traction packs and DC fast-charging stations.
Kereszthivatkozás Can VIOX VOSA square-body fuses replace Bussmann 170M and Mersen Protistor?
Yes. VOSA000 through VOSA7-PK follow IEC 60269-4 and DIN 43653/flush-end mechanical footprints. Send your current 170M or Protistor part number and VIOX engineers will verify I²t and mounting dimensions.
Need High-Speed Semiconductor & EV Fuses Datasheets or BOM Cross-Ref?
Talk Directly with VIOX Engineers.
Send your rated voltage, ampere steps, breaking capacity, or Tier-1 part numbers for rapid factory pricing and evaluation samples.
Request High-Speed Semiconductor & EV Fuses Quote