VIOX VRO10-63 2P 63A Type B 10kA RCBO

VIOX VRO10-63 2P RCBO offers advanced B-type residual current protection for diverse electrical applications. This IEC62423-compliant device features a 10kA breaking capacity and supports currents up to 63A at 230V. With sensitivity options of 30mA, 100mA, or 300mA, it provides comprehensive protection against various waveforms, including high-frequency up to 1kHz. The RCBO offers B, C, and D tripping curves, IP20 protection, and operates from -25°C to +40°C. Key advantages include bi-connect termination for busbar/cable flexibility, efficient air circulation design, and easy 35mm DIN rail mounting. Boasting 10,000 mechanical and 4,000 electrical life cycles, this versatile RCBO ensures long-lasting, reliable protection against earth faults, overloads, and short circuits in both residential and commercial settings.

الزامات خود را ارسال کنید، ما ظرف 12 ساعت برای شما نقل قول خواهیم کرد

VIOX VRO10-63 2P 63A Type B 10kA Residual Current Circuit Breaker with Overload Protection RCBO

نمای کلی

The VIOX VRO10-63 is a high-performance 2-pole Residual Current Circuit Breaker with Overload Protection (RCBO) designed for efficient protection in electrical systems. It offers a 10kA rated breaking capacity and is available in various current ratings up to 63A.

ویژگی‌های کلیدی

  • Standard: IEC62423
  • Type: B Type (sensitive to various waveforms of earth leakage)
  • Model: Electromagnetic
  • Rated current (In): 6, 10, 16, 20, 25, 32, 40, 50, 63A
  • Trip curve: B, C, D
  • Poles: 2P
  • Rated voltage (Ue): 230V
  • Rated sensitivity (I△n): 30, 100, 300mA
  • Rated breaking capacity (Icn): 10000A
  • Rated operating short circuit breaking capacity (Ics): 7500A

مشخصات فنی

  • Mechanical life: 10000 cycles
  • Electrical life: 4000 cycles
  • Protection degree: IP20
  • Ambient temperature: -25°C to +40°C (with daily averages 35°C)
  • Storage temperature: -25°C to +70°C
  • Connection capacity: 25mm² (input and output)
  • Tightening torque: 2Nm (input and output)
  • Installation: 35mm DIN rail
  • Rated residual making and breaking capacity (I△m): 2000A
  • Break time under I△n: ≤0.1S
  • Rated impulse withstand voltage (Uimp): 4KV
  • Dielectric test voltage at ind. freq. for 1 min: 2KV

Special Design Features

  • Air circulation: Adjacent poles form air channels for effective cooling
  • Bi-connect Termination: Allows use of busbar and/or cable in the same terminal
  • Din Rail Mounting: Two-step snapping mechanism for easy and secure mounting

Waveform Sensitivity (B Type)

Waveform definition Waveform جریان قطع
Sinusoidal exchange ~ 0.5-1 I△n
Pulsating half wave Λ 0.5-1.4 I△n
Pulsing half wave+direct current (6mA) ~~ Max 1.4 I△n+6mA
Pulsing half wave+direct current (10mA) ~~ Max 1.4 I△n+10mA
High frequency (up to 1KHz) ΛΛΛΛ 150Hz 0.5-2.4 I△n
400Hz 0.5-6 I△n
1000Hz 1-14 I△n
Two phase rectified full wave 0.5-2 I△n
Three phase rectified full wave ∿∿ 0.5-2 I△n
Direct current 0.5-2 I△n