VIOX VL16-40 AC typ 1P+N RCBO

VIOX VL16-40 AC Type 1P+N RCBO offers comprehensive protection for household and commercial distribution systems. This IEC/EN61009-1 compliant device safeguards against earth faults, short-circuits, and overloads with a 10kA rated short-circuit capacity. Available in 1A to 40A ratings, it operates at 240V AC, 50/60Hz, with residual current options of 30mA, 100mA, or 300mA. Featuring B, C, or D tripping curves and instantaneous tripping ≤0.1s, it provides efficient protection against insulation failures and direct human contact. With easy DIN rail mounting and 4000 cycle electro-mechanical endurance, this versatile RCBO ensures reliable electrical safety for various applications.

Pošlete nám své požadavky, nabídku vám zašleme do 12 hodin.

VIOX VL16-40 AC Type 1P+N Residual Current Circuit Breaker with Overcurrent Protection RCBO

Přehled

The VIOX VL16-40 RCBO provides comprehensive protection for household and commercial distribution systems. It offers protection against earth fault/leakage current, short-circuit, overload, and functions as an isolation device. This device effectively safeguards electric equipment against insulating failure and provides complementary protection against direct contact by human body.

Klíčové vlastnosti

  • Standards: IEC/EN61009-1
  • Type: Electro-magnetic type
  • Residual current characteristics: AC A
  • Pole No.: 1P+N
  • Křivka zakopnutí: B, C, D
  • Rated short-circuit capacity: 10kA
  • Rated current (A): 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A
  • Rated voltage: 240V AC
  • Jmenovitá frekvence: 50/60Hz
  • Rated residual operating current(mA): 0.03, 0.1, 0.3
  • Tripping duration: instantaneous≤0.1s
  • Electro-mechanical endurance: 4000 cycles

Technické specifikace

  • Connection terminal: pillar terminal with clamp
  • Connection capacity: Rigid conductor 16mm²
  • Terminal connection height: 21.5mm
  • Installation: On symmetrical DIN rail 35mm or Panel mounting

Charakteristiky proudové ochrany proti přetížení

Zkušební postup Typ Testovací proud Počáteční stav Časový limit pro jízdu nebo bez ní Očekávaný výsledek Poznámka
a B,C,D 1.13In studené t≥1h No tripping
b 1.45In po testu a t<1h zakopnutí Current in the 5s in the increase of stability
c 2.55In studené 1s<t<60s zakopnutí
d B
C
D
3V
5In
10In
studené t≥0.1s No tripping Zapněte pomocný spínač, abyste uzavřeli proud.
e B
C
D
5In
10In
20In
studené t<0,1s zakopnutí Zapněte pomocný spínač, abyste uzavřeli proud.

The terminology “cold state” refers to that no load is carried before testing at the reference setting temperature.

Residual Current Action Breaking Time

Typ V/A I△n/A Zbytkový proud (I△) odpovídá následující době přerušení (S)
AC type any value any value In 2V 5In 5A,10A,20A,50A,100A,200A,500A
A type any value >0.01 1.4In 2.8In 7In
0.3 0.15 0.04 0.04 Maximální doba přestávky
Obecný typ RCBO, jehož proud IΔn je 0,03 mA nebo méně, může místo 5IΔn použít 0,25 A.

Charakteristická křivka

Schéma zapojení