The VIOX FCT18-B/Bt Off-Delay Timer Relay provides precise interval timing for industrial control systems. Features a wide time range (0.1s – 100 days) with <0.5% error, retrigger control signal input (NPN/PNP), and DIN rail mounting. Ideal for controlled shutdowns and process timing.

আপনার প্রয়োজনীয়তা পাঠান, আমরা 12 ঘন্টার মধ্যে আপনার জন্য উদ্ধৃতি দেব।

ভূমিকা

The VIOX FCT18-B/Bt is a high-performance interval relay with retrigger control signal designed for precise timing applications in industrial environments. As a professional-grade off-delay timer relay, it offers exceptional reliability, accuracy, and versatility for controlling machinery, equipment, and automated processes across various industries.

What Are Off-Delay Timer Relays?

Timer relays are essential components in industrial control systems that provide simple, reliable, and economical timing solutions. The off-delay timer relay, specifically, maintains its output during the input signal and continues for a predetermined time after the input signal stops. This functionality is crucial for applications requiring controlled shutdown sequences, cooling periods, or continued operation after trigger events.

Key Benefits of Off-Delay Timer Relays

  • Controlled Shutdown: Ensures equipment powers down safely and in the correct sequence
  • Extended Operation: Maintains power to components after the initial signal ends
  • Process Timing: Provides precise timing intervals for critical industrial processes
  • সরঞ্জাম সুরক্ষা: Prevents damage from sudden power interruptions

VIOX FCT18-B/Bt Series Features

The FCT18-B/Bt series represents VIOX’s commitment to providing high-quality timing solutions with exceptional performance characteristics:

বহুমুখী সময় নির্ধারণের ফাংশন

The FCT18-B/Bt offers two distinct timing modes:

  1. B: OFF-delay – Standard off-delay function that maintains output for a preset time after trigger signal ends
  2. Bt: OFF-delay + instantaneous – Combines off-delay functionality with instantaneous output contacts

VIOX FCT18-B_Bt Off-Delay Timer Relay with Retrigger Control Signal Timing Functions

ব্যতিক্রমী সময়সীমার নমনীয়তা

With time settings spanning from 0.1 seconds to 100 days, the FCT18-B/Bt can accommodate virtually any industrial timing requirement:

VIOX FCT18-B_Bt Off-Delay Timer Relay with Retrigger Control Signal Time range

  • ০.১-১ সেকেন্ড: দ্রুত চক্র প্রয়োগের জন্য যেখানে সুনির্দিষ্ট স্বল্প-সময়ের সময় প্রয়োজন
  • ১-১০ সেকেন্ড: স্ট্যান্ডার্ড শর্ট-সাইকেল শিল্প প্রক্রিয়ার জন্য আদর্শ
  • ০.১-১ মি: মিনিট-ভিত্তিক প্রক্রিয়া নিয়ন্ত্রণের জন্য উপযুক্ত
  • ১-১০ মিটার: দীর্ঘ প্রক্রিয়া চক্রের জন্য উপযুক্ত
  • ০.১-১ ঘন্টা: ঘন্টাভিত্তিক চক্র প্রয়োগের জন্য
  • ১-১০ ঘন্টা: বর্ধিত ঘন্টা-ভিত্তিক সময় নিয়ন্ত্রণ
  • ০.১-১ দিন: বর্ধিত প্রক্রিয়ার জন্য দৈনিক চক্র নিয়ন্ত্রণ
  • ১-১০ দিন: দীর্ঘমেয়াদী প্রক্রিয়ার জন্য বহু-দিনের সময়কাল
  • ৩-৩০ দিন: মাসিক চক্রের আবেদনপত্র
  • ১০-১০০ দিন: মৌসুমী আবেদনের জন্য বর্ধিত সময়কাল

Precise Ratio Settings

Fine-tune your timing requirements with ratio settings from 10% to 100% in 5% increments:

VIOX FCT18-B_Bt Off-Delay Timer Relay with Retrigger Control Signal ratio settings

কারিগরি বিবরণ

স্পেসিফিকেশন FCT18-B1 FCT18-B2 FCT18-Bt
ইনপুট টার্মিনাল A1-A2 A1-A2 A1-A2
ভোল্টেজ পরিসীমা এসি ২৩০ ভোল্ট / ডিসি২৪ ভোল্ট / এসি/ডিসি ১২-২৪০ ভোল্ট এসি ২৩০ ভোল্ট / ডিসি২৪ ভোল্ট / এসি/ডিসি ১২-২৪০ ভোল্ট এসি ২৩০ ভোল্ট / ডিসি২৪ ভোল্ট / এসি/ডিসি ১২-২৪০ ভোল্ট
বিদ্যুৎ খরচ এসি ৩.৫ ভিএ/ ডিসি ২.০ ওয়াট এসি ৩.৫ ভিএ/ ডিসি ২.০ ওয়াট এসি ৩.৫ ভিএ/ ডিসি ২.০ ওয়াট
ভোল্টেজ সহনশীলতা -15% ~ +10% -15% ~ +10% -15% ~ +10%
সরবরাহের ইঙ্গিত সবুজ এলইডি সবুজ এলইডি সবুজ এলইডি
রিলে ইঙ্গিত লাল এলইডি লাল এলইডি লাল এলইডি
সময়সীমা ০.১ সেকেন্ড-১০০ দিন ০.১ সেকেন্ড-১০০ দিন ০.১ সেকেন্ড-১০০ দিন
সময় নির্ধারণ বোতাম বোতাম বোতাম
সময়ের বিচ্যুতি 0.1% 0.1% 0.1%
পুনরাবৃত্তির নির্ভুলতা 0.5% 0.5% 0.5%
তাপমাত্রা সহগ ০.০৫১TP3T/°C, = ২০°C তাপমাত্রায় (০.০৫১TP3T/°F, = ৬৮°F) ০.০৫১TP3T/°C, = ২০°C তাপমাত্রায় (০.০৫১TP3T/°F, = ৬৮°F) ০.০৫১TP3T/°C, = ২০°C তাপমাত্রায় (০.০৫১TP3T/°F, = ৬৮°F)
আউটপুট যোগাযোগ ১*এসপিডিটি ২*এসপিডিটি ১*এসপিডিটি+১*এসপিডিটি
রেট করা বর্তমান ১*১৬এ ২*১৬এ ২*১৬এ
যান্ত্রিক জীবন ১*১০⁷ ১*১০⁷ ১*১০⁷
বৈদ্যুতিক জীবনকাল ১*১০⁵ ১*১০⁵ ১*১০⁵
পরিবেষ্টিত তাপমাত্রা -২০ … +৬০°সে / -৪০ … +৮৫°সে -২০ … +৬০°সে / -৪০ … +৮৫°সে -২০ … +৬০°সে / -৪০ … +৮৫°সে
মাউন্টিং ডিআইএন রেল EN/IEC 60715 ডিআইএন রেল EN/IEC 60715 ডিআইএন রেল EN/IEC 60715
আইপি রেটিং আইপি২০ আইপি২০ আইপি২০
স্ট্রিপিং দৈর্ঘ্য ৭ মিমি (০.২৮ ইঞ্চি) ৭ মিমি (০.২৮ ইঞ্চি) ৭ মিমি (০.২৮ ইঞ্চি)
ইনস্টল করা উচ্চতা ≤২২০০ মি ≤২২০০ মি ≤২২০০ মি
দূষণের মাত্রা 2 2 2
সর্বোচ্চ তারের আকার AWG১৩-২০ ০.৪N·মি AWG১৩-২০ ০.৪N·মি AWG১৩-২০ ০.৪N·মি
মাত্রা ৯০ মিমি × ১৮ মিমি × ৬৪ মিমি ৯০ মিমি × ১৮ মিমি × ৬৪ মিমি ৯০ মিমি × ১৮ মিমি × ৬৪ মিমি
ওজন প্রায় ৯০ গ্রাম প্রায় ৯০ গ্রাম প্রায় ৯০ গ্রাম
মানদণ্ড জিবি/টি ১৪০৪৮.৫, আইইসি৬০৯৪৭-৫-১, এন৬৮১২-১ জিবি/টি ১৪০৪৮.৫, আইইসি৬০৯৪৭-৫-১, এন৬৮১২-১ জিবি/টি ১৪০৪৮.৫, আইইসি৬০৯৪৭-৫-১, এন৬৮১২-১

আউটপুট বিকল্প

The FCT18-B/Bt series offers multiple output configurations to match your control requirements:

  • FCT18-B1: 1CO contact (1×SPDT)
  • FCT18-B2: 2CO contacts (2×SPDT)
  • FCT18-Bt: 1CO contact + 1 instantaneous contact (1×SPDT + 1×SPDT)

নিয়ন্ত্রণ সংকেত বিকল্প

  • : NPN control signal
  • : PNP control signal

Common Industrial Applications for Off-Delay Timer Relays

Timer relays like the FCT18-B/Bt provide critical timing functions across numerous industrial applications:

আলো নিয়ন্ত্রণ

Off-delay timer relays enable the delayed switching of multiple rows of lamps in production facilities or greenhouses, ensuring proper illumination cycles and energy efficiency.

Motor Control

Star-delta motor starting with changeover delay helps reduce starting current and prevents interphase short-circuits, protecting valuable equipment and extending motor life.

Cyclic Operations

Manage the weekly startup of fans to prevent machinery from sticking, or control the flushing of pipes to keep them clear—ideal for maintenance automation.

অতিরিক্ত অ্যাপ্লিকেশন

  • Control panels: Sequence operations with precise timing
  • Pump controls: Prevent dry running and manage fluid levels
  • যন্ত্র সরঞ্জাম: Control operational sequences
  • Automatic doors: Manage opening/closing cycles
  • Car park barriers: Regulate traffic flow
  • Compressor controls: Optimize pressure cycles
  • পরিবহন ব্যবস্থা: Synchronize movement
  • Industrial refrigeration: Manage defrost cycles
  • Packaging machines: Control product handling
  • Baking ovens: Manage temperature cycles
  • Water and wastewater: Control treatment processes
  • Wind energy: Synchronize turbine operations
  • Industrial cleaning: Automate cleaning sequences

Advantages of the VIOX FCT18-B/Bt Off-Delay Timer Relay

Versatile Power Supply

With a wide power supply range from 12 to 240 VAC/DC, the FCT18-B/Bt can be integrated into virtually any electrical system without requiring additional power converters.

User-Friendly Setup

Installation is simplified with clear wiring diagrams on the side of the product, reducing setup time and minimizing the risk of connection errors.

ব্যতিক্রমী নির্ভুলতা

With a time error less than 0.5%, time deviation of 0.1%, and repeat accuracy of 0.5%, the FCT18-B/Bt delivers the precision timing required for critical industrial processes.

শিল্প-গ্রেড নির্ভরযোগ্যতা

The strong anti-interference capability ensures consistent operation even in electrically noisy industrial environments where electrical spikes and surges are common.

কমপ্যাক্ট ডিজাইন

With dimensions of 90mm×18mm×64mm, the FCT18-B/Bt offers substantial functionality in a compact package, saving valuable space in control panels and electrical enclosures.

Visual Status Indication

  • সবুজ এলইডি: Supply indication
  • লাল এলইডি: Relay activation indication

পর্যবেক্ষণ এবং সুরক্ষা বৈশিষ্ট্য

The FCT18-B/Bt timer relay functions as part of a comprehensive control and monitoring system:

Three-phase Voltage Monitoring

  • মোবাইল থ্রি-ফেজ সরঞ্জামের ভোল্টেজ পর্যবেক্ষণ
  • ফেজ রিভার্সালের বিরুদ্ধে কর্মী এবং স্থাপনাগুলির সুরক্ষা
  • Monitoring of supply voltage of machines and installations
  • Protection against damage caused by unstable supply voltage
  • Switching to emergency or auxiliary supply when necessary

Single-phase Current Monitoring

  • মোটর কারেন্ট খরচ পর্যবেক্ষণ
  • আলো স্থাপন এবং হিটিং সার্কিটের পর্যবেক্ষণ
  • পরিবহন সরঞ্জামের অতিরিক্ত চাপ পর্যবেক্ষণ
  • লকিং ডিভাইস, ইলেক্ট্রোমেকানিক্যাল ব্রেক গিয়ার এবং লক করা রোটরগুলির পর্যবেক্ষণ

Single-phase Voltage Monitoring

  • ডিসি মোটরের গতি পর্যবেক্ষণ
  • ব্যাটারি ভোল্টেজ এবং অন্যান্য সরবরাহ নেটওয়ার্কের পর্যবেক্ষণ

তরল স্তর পর্যবেক্ষণ

  • শুষ্ক চলমান বিরুদ্ধে পাম্প সুরক্ষা
  • কন্টেইনার ওভারফ্লো থেকে সুরক্ষা
  • তরল স্তর নিয়ন্ত্রণ
  • লিক সনাক্তকরণ
  • মিশ্রণ অনুপাত নিয়ন্ত্রণ

ইনস্টলেশন এবং সেটআপ

তারের বিকল্প

The FCT18-B/Bt supports both NPN and PNP control signal configurations:

এনপিএন কনফিগারেশন

  • Connect Un to power supply
  • Connect S to control signal
  • Output terminals: 11-14(R1) and 21-24(R2)

পিএনপি কনফিগারেশন

  • Connect Un to power supply
  • Connect S to control signal
  • Output terminals: 11-14(R1) and 21-24(R2)

VIOX FCT18-B_Bt Off-Delay Timer Relay with Retrigger Control Signal wiring

Dimension Specifications

The compact design allows for easy installation in standard control panels:

  • উচ্চতা: 90 মিমি
  • প্রস্থ: ১৮ মিমি
  • গভীরতা: ৬৪ মিমি

VIOX FCT18-B_Bt Off-Delay Timer Relay with Retrigger Control Signal dimension

মডেল নির্বাচন নির্দেশিকা

The FCT18 model designation system allows you to specify exactly the right timer relay for your application:

FCT18- B 1 W N

  1. ফাংশন: B (Off-delay) or Bt (Off-delay + instantaneous)
  2. আউটপুটের ধরণ: 1 (1CO contact) or 2 (2CO contacts)
  3. সরবরাহ ভোল্টেজ: A (AC230V), D (DC24V), or W (AC/DC12-240V)
  4. নিয়ন্ত্রণ সংকেত: N (NPN) or P (PNP)

Quality Standards

The VIOX FCT18-B/Bt is manufactured to comply with international standards:

  • জিবি/টি ১৪০৪৮.৫
  • আইইসি 60947-5-1
  • EN6812-1 এর বিবরণ

উপসংহার

The VIOX FCT18-B/Bt off-delay timer relay represents an ideal solution for industrial timing applications requiring precision, reliability, and versatility. With its extensive range of timing functions, exceptional accuracy, and robust design, it delivers consistent performance in demanding industrial environments.

Whether you need precise control of lighting systems, motor starting sequences, or cyclic operations, the FCT18-B/Bt provides the timing functionality required for efficient automation. Its user-friendly setup, compact design, and comprehensive monitoring capabilities make it an essential component in modern industrial control systems.

For applications requiring reliable time-delayed switching to start motors, control loads, or manage processes, the VIOX FCT18-B/Bt off-delay timer relay offers a professional-grade solution that combines performance, durability, and value.

সংশ্লিষ্ট পণ্য

এখনই উদ্ধৃতি চাইতে পারেন

এখনই উদ্ধৃতি চাইতে পারেন