VOQ4-100R Dual Power Automatic Transfer Switch
- Control device: built in na controller
- Product structure: no power off, guide rail type, high current, small volume, two-stage type, simple structure, ATS integration
- Mga Tampok: mabilis na bilis ng paglipat, mababang rate ng pagkabigo, maginhawang pagpapanatili at maaasahang pagganap
- Wiring mode: front plate wiring
- Conversion mode: power grid sa power grid, power grid sa generator, awtomatikong switching at self recovery
- Frame ng produkto: 100
- Product current: 10, 16, 20, 25, 32, 40, 50, 63,80, 100A
- Pag-uuri ng produkto: direktang uri ng pagkarga
- Pole No.: 2,3,4
- Pamantayan: GB/T14048.11
- ATSE: klase sa PC
- Oras ng paglipat: 0.008s/8ms
Ipadala ang iyong mga kinakailangan, mag-quote kami para sa iyo sa loob ng 12 oras
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:sales@viox.com
Pangkalahatang-ideya ng Produkto
Ang VOQ4-100R Dual Power Automatic Transfer Switch from VIOX Electric represents cutting-edge power management technology designed for critical applications requiring uninterrupted power supply. This miniaturized household and commercial power switch automatically detects the status of both main power supply and standby power supply, ensuring seamless power transition during outages or power quality issues.
Mga Pangunahing Tampok at Benepisyo
Intelligent na Awtomatikong Operasyon
- Automatic detection and switching between main and standby power sources
- Fast switching time: ≤0.008s/8ms for minimal power interruption
- Manual and automatic operation modes for maximum flexibility
Robust Design & Reliability
- Solid structure with reliable conversion and convenient installation
- Conforms to GB/T14048.11 national standards
- Wide operating temperature range: -40°C to +70°C
- Pollution grade 3 rating for harsh environments
Maraming Gamit na Application
- Specially designed for household rail installation
- Perfect for FZC distribution boxes and power distribution systems
- Suitable for 50/60Hz power systems up to 400V AC
- Available in 2P, 3P, and 4P configurations
Teknikal na Pagtutukoy
[INSERT IMAGE: Technical specifications table and dimensions diagram]
Mga Parameter ng Elektrisidad
Parameter | 2P Configuration | 3P Configuration | 4P Configuration |
---|---|---|---|
Na-rate na Kasalukuyan (Sa) | 16A, 20A, 25A | 32A, 40A, 50A, 63A | 80A, 100A |
Rated Voltage (Un) | AC400V, 50Hz | AC400V, 50Hz | AC400V, 50Hz |
Boltahe ng Insulation (Ui) | AC400V, 50Hz | AC400V, 50Hz | AC400V, 50Hz |
Timbang | 0.55kg | 0.6kg | 0.65kg |
Short Circuit Current | 50kA | 50kA | 50kA |
Mga Katangian ng Pagganap
- Control Circuit: AC220V/50Hz rated control voltage
- Auxiliary Circuit: 2 relays with auxiliary contacts
- Oras ng Conversion: ≤50ms for all switching operations
- Oras ng Power Off: ≤50ms
- Switching Capability: 0.008s/8ms response time
Pag-install at Pag-wire
Mga Kinakailangan sa Pag-install
Mga Kondisyon sa Kapaligiran
- Operating Temperatura: -40°C to +70°C ambient
- Temperatura ng Imbakan: -5°C to +35°C
- Kamag-anak na Humidity: ≤95% at 35°C maximum
- Installation Altitude: ≤2000m above sea level
- Grado ng Polusyon: Grade 3 classification
Mga Alituntunin sa Pag-install
- Ensure professional installation by qualified electricians
- Verify all power sources are disconnected before installation
- Follow proper safety distance requirements (S1: >30mm, S2: >20mm)
- Use appropriate circuit breakers for overcurrent protection
- Maintain proper ventilation and dust-free environment
Pag-configure ng mga kable
The VOQ4-100R Dual Power Automatic Transfer Switch supports multiple wiring configurations:
- Standard Wiring: For typical dual power applications
- Timing Switch Connection: For scheduled power management
- Generator Integration: Seamless backup generator connection
- Pamamahala ng Pagkarga: Priority load switching capabilities
Mga Application at Use Case
Mga Aplikasyon sa Paninirahan
- Mga backup na sistema ng kuryente sa bahay
- Critical appliance protection
- Solar panel integration with grid backup
- Mga sistema ng pang-emergency na ilaw
Mga Komersyal na Aplikasyon
- Office buildings and retail facilities
- Mga sentro ng data at mga silid ng server
- Medical facilities and hospitals
- Industrial manufacturing plants
Model Designation
VOQ4-100-R Model Breakdown:
- V: VIOX Electric brand identifier
- O: Optimized design series
- Q4: Quad-pole maximum configuration
- 100: 100A maximum current rating
- R: Rail-mount installation type
Regular na Iskedyul sa Pagpapanatili
Mga Buwanang Inspeksyon
- Visual inspection for physical damage or overheating
- Check terminal connections for tightness
- Verify indicator lights and display functions
Taunang Pagpapanatili
- Complete electrical testing and calibration
- Pagsukat ng paglaban sa contact
- Insulation resistance testing (minimum 10MΩ)
- Operating mechanism lubrication
Safety Recommendations
- Always disconnect all power sources before maintenance
- Use proper personal protective equipment (PPE)
- Sundin ang mga pamamaraan ng lockout/tagout
- Panatilihin ang mga detalyadong talaan ng pagpapanatili
Compliance & Standards
The VOQ4-100R Dual Power Automatic Transfer Switch meets or exceeds:
- GB/T14048.11: Chinese national standard for automatic transfer switches
- Mga Pamantayan ng IEC: International electrical safety requirements
- Nakalista sa UL: Underwriters Laboratories certification
- Pagmarka ng CE: European conformity standards
Why Choose VIOX Electric?
Industry Expertise
With decades of experience in power management solutions, VIOX Electric delivers reliable, innovative products that meet the most demanding applications.
Quality Assurance
Every VOQ4-100R undergoes rigorous testing and quality control procedures to ensure long-term reliability and performance.
Teknikal na Suporta
Our experienced engineering team provides comprehensive technical support, from product selection to installation guidance and troubleshooting.
Saklaw ng Warranty
VIOX Electric backs the VOQ4-100R with comprehensive warranty coverage and readily available replacement parts.
Madalas Na Tinatanong Na Mga Katanungan
Q: What is the difference between manual and automatic operation modes?
A: Automatic mode provides hands-free operation with intelligent power source monitoring, while manual mode allows operator control for maintenance or testing purposes.
Q: Can the VOQ4-100R handle generator backup systems?
A: Yes, the switch is specifically designed to work with generator backup systems, providing seamless transition when utility power fails.
Q: What maintenance is required?
A: Regular visual inspections monthly and comprehensive electrical testing annually by qualified technicians ensure optimal performance.
Q: Is the unit suitable for outdoor installation?
A: The VOQ4-100R is designed for indoor installation in electrical panels. For outdoor applications, appropriate enclosure protection is required.
Technical Downloads
- Product Datasheet (PDF)
- Installation Manual (PDF)
- Wiring Diagrams (CAD)
- Compliance Certificates (PDF)
Contact & Support
Ready to enhance your power reliability with the VOQ4-100R Dual Power Automatic Transfer Switch? Our technical experts are standing by to help you select the right configuration for your specific application.
Get a Quote Today
- Technical consultation available
- Custom configurations possible
- Competitive pricing and fast delivery
- Comprehensive warranty and support
*The VOQ4-100R Dual Power Automatic Transfer Switch from VIOX Electric – Your reliable partner for uninterrupted power management solutions.*
Keywords: Dual Power Automatic Transfer Switch, Automatic Transfer Switch, Power Management, Backup Power, Emergency Power, VIOX Electric, VOQ4-100R, Electrical Safety, Power Reliability