နိဒါန်း
Metal components in electrical systems are under siege. Humidity creeps in. Salt spray corrodes. Industrial atmospheres accelerate degradation. Without proper protection, corrosion transforms reliable equipment into costly failures. This is where ISO 12944 enters—the global standard that translates environmental severity into actionable design decisions for protective coating systems.
ISO 12944 operates on two axes. The first defines how aggressive your environment truly is—ranging from climate-controlled offices (C1) to extreme offshore platforms (CX). The second sets your maintenance timeline: from inexpensive touch-ups every 7 years to robust systems lasting 25+ years. Understanding this framework is essential for engineers specifying steel structures, electrical enclosure bodies, and structural support systems. It directly shapes procurement, maintenance budgets, and equipment lifespan.
This guide decodes ISO 12944 into practical language and connects the standard to real industrial applications.

What Is ISO 12944?
ISO 12944 is the international standard for corrosion protection of steel structures by protective paint systems. It applies specifically to structural steel components and steel electrical enclosure bodies exposed to atmospheric environments. First released in 1998, it has evolved into the globally recognized benchmark for specifying coating systems. The 2018 revision—the current standard—introduced the CX (extreme) category and expanded durability options to address modern industrial challenges like offshore wind, coastal solar installations, and aggressive tropical environments.
Important Scope Clarification: ISO 12944 is NOT applied to individual electrical components inside enclosures—such as terminal blocks, MCBs, contactors, or other conductive parts. These components require separate corrosion protection strategies (see “Application Boundaries” section below). The standard focuses exclusively on the painted/coated steel surfaces of structures and enclosure bodies.
The standard’s power lies in its simplicity: no guesswork. Instead of arguing over vague requirements like “good paint” or “marine grade,” ISO 12944 provides precise specifications—surface preparation grades, primer types, dry film thickness (DFT), number of coats, and laboratory test procedures. This objectivity makes it the foundation for tenders, procurement contracts, and quality verification worldwide.
Corrosivity Categories: C1 Through CX

ISO 12944-2 classifies environments into six corrosivity categories. Each category is defined by measurable factors: humidity levels, result from condensation, atmospheric pollutants (SO₂), and salt deposition in coastal areas. The standard quantifies corrosivity by measuring mass loss and thickness loss of standard steel and zinc specimens exposed for one year.
C1: Very Low Corrosivity
Typical Environment: Heated, air-conditioned buildings with clean air
ဥပမာ: Office buildings, schools, hotels, shopping malls
Interior Focus: Yes (exterior C1 is rare)
Steel Loss (Year 1): ≤1.3 µm
Zinc Loss (Year 1): ≤0.1 µm
Typical Maintenance Interval: 10–15 years minimum
C1 is essentially corrosion immunity. In controlled indoor environments, even uncoated aluminum can last indefinitely. Coating systems here are minimal—a single coat of acrylic or alkyd, total DFT around 60–100 µm.
C2: Low Corrosivity
Typical Environment: Rural areas, temperate zones, minimal pollution; unheated buildings with condensation risk
ဥပမာ: Rural warehouses, agricultural facilities, sports halls
Steel Loss (Year 1): >1.3 to 25 µm
Zinc Loss (Year 1): >0.1 to 0.7 µm
Typical Maintenance Interval: 7–10 years
C2 applies to clean outdoor environments or unheated indoor spaces. Salt air is absent. SO₂ pollution is minimal. Coating systems step up modestly: a primer + single topcoat, DFT 100–150 µm.
C3: Medium Corrosivity
Typical Environment: Urban and industrial atmospheres; moderate SO₂ pollution; low-salinity coastal areas
ဥပမာ: City factories, food processing plants, breweries, laundries, low-salinity coastal installations
Interior Examples: High-humidity production rooms with some pollution
Steel Loss (Year 1): >25 to 50 µm
Zinc Loss (Year 1): >0.7 to 2.1 µm
Typical Maintenance Interval: 5–7 years (first major maintenance)
C3 is where many industrial facilities land. Humidity is elevated; condensation occurs regularly. The air carries industrial dust and mild SO₂. Coatings now include zinc-rich epoxy primers and polyurethane topcoats for UV resistance. Total DFT: 120–200 µm. C3 environments are typical for structural steel, equipment frames, and electrical enclosure bodies in urban factories and food processing plants. Interior components like terminal blocks, MCBs, and contactors inside C3-protected cabinets use their own protection strategies (electroplating, stainless materials) as described in the “Application Boundaries” section.
C4: High Corrosivity
Typical Environment: Industrial areas with moderate salinity; coastal regions with seasonal salt spray
ဥပမာ: Chemical plants, swimming pool facilities, moderate-salinity shipyards, coastal industrial zones
Steel Loss (Year 1): >50 to 80 µm
Zinc Loss (Year 1): >2.1 to 4.2 µm
Typical Maintenance Interval: 4–5 years (first major maintenance)
C4 introduces serious corrosion risk. Salt spray is now a factor. Humidity stays high. A bare steel panel exposed to C4 will show visible rust within months. Coatings require 2–3 layers: zinc-rich epoxy primer (100–150 µm), epoxy intermediate (100–150 µm), polyurethane topcoat (80–100 µm). Total DFT: 200–250 µm. This applies to structural steel and enclosure/cabinet bodies. VIOX ကေဘယ်ဂလင်းများ နှင့် waterproof connectors used as cable entries through C4-painted enclosure walls are rated per IEC 60068-2-11 and IP ratings (see “Application Boundaries” section).
C5: Very High Corrosivity
Typical Environment: High-humidity industrial areas with aggressive atmospheres; high-salinity coastal regions
ဥပမာ: Offshore support bases, chemical processing plants in humid regions, high-salinity marine installations, tropical industrial sites
Steel Loss (Year 1): >80 မှ 200 µm
Zinc Loss (Year 1): >4.2 မှ 8.4 µm
Typical Maintenance Interval: 3–4 နှစ် (ပထမအကြိမ် အဓိက ပြုပြင်ထိန်းသိမ်းမှု)
C5 သည် အလွန်ပြင်းထန်သည်။ သံချေးတက်ခြင်းသည် အရှိန်အဟုန်ဖြင့် ဆက်လက်ဖြစ်ပေါ်သည်။ သံမဏိတုံး အကာအကွယ်မဲ့တစ်ခုသည် တစ်နှစ်အတွင်း နက်ရှိုင်းသော အပေါက်များနှင့် သိသာထင်ရှားသော အလေးချိန် ဆုံးရှုံးမှုကို ပြသလိမ့်မည်။ အပေါ်ယံလွှာစနစ်များသည် အလွန်အကြမ်းခံလာသည်- သွပ်ကြွယ်ဝသော အောက်ခံအလွှာ (100–150 µm), အထူထပ်မြင့် အလယ်အလွှာ (150–250 µm), polyurethane အပေါ်ဆုံးအလွှာ (100–150 µm)။ စုစုပေါင်း DFT သည် 300–320 µm ထက် မကြာခဏ ကျော်လွန်သည်။ အလွှာများစွာကို မဖြစ်မနေ လိမ်းရမည်။ မျက်နှာပြင် ပြင်ဆင်မှုသည် ကပ်ညှိမှုကို သေချာစေရန် Sa3 (အဖြူရောင်နီးပါး သန့်စင်ခြင်း) သို့ ရောက်ရှိရမည်။ ၎င်းသည် စံနှုန်းဖြစ်သည် ပင်လယ်ပြင်ရှိ ဖွဲ့စည်းတည်ဆောက်ပုံများ၊ ရေကြောင်းသယ်ယူပို့ဆောင်ရေးယာဉ်များနှင့် အရေးကြီးသော စက်မှုအခြေခံအဆောက်အအုံများအတွက်. ဤဖွဲ့စည်းပုံများအတွင်း တပ်ဆင်ထားသော အစိတ်အပိုင်းများ (VIOX သို့မဟုတ် အခြားသူများထံမှ) သည် ISO 12944 မဟုတ်ဘဲ လျှပ်စစ်စံနှုန်းများကို လိုက်နာသည်။.
CX: အလွန်အမင်း သံချေးတက်ခြင်း
Typical Environment: ပင်လယ်ပြင်ရှိ ဆားငန်ဓာတ်မြင့်မားသော ဇုန်များ၊ အလွန်အမင်း စိုထိုင်းဆ + ပြင်းထန်သော စက်မှုလေထု၊ စဉ်ဆက်မပြတ် စိုထိုင်းဆရှိသော အပူပိုင်း/အပူပိုင်းဒေသ ရာသီဥတုများ
ဥပမာ: ပင်လယ်ပြင် ရေနံနှင့်ဓာတ်ငွေ့ပလက်ဖောင်းများ၊ အလွန်အမင်း အပူပိုင်းဒေသ ကမ်းရိုးတန်း တပ်ဆင်မှုများ၊ ပင်လယ်ရေအောက်ပစ္စည်း ကူညီပံ့ပိုးပေးသော ဖွဲ့စည်းပုံများ
Steel Loss (Year 1): >200 မှ 700 µm
Zinc Loss (Year 1): >8.4 မှ 25 µm
Typical Maintenance Interval: 2–3 နှစ် (ပထမအကြိမ် အဓိက ပြုပြင်ထိန်းသိမ်းမှု)
CX သည် နယ်နိမိတ်ဖြစ်သည်။ စံနှုန်းသည် ခေတ်မီစွမ်းအင် အသွင်ကူးပြောင်းမှုများကို (ပင်လယ်ပြင် လေအားလျှပ်စစ်ခြံများ၊ ရေပေါ်ဆိုလာ) ကိုင်တွယ်ဖြေရှင်းရန် ဤအမျိုးအစားကို 2018 ခုနှစ်တွင် စတင်မိတ်ဆက်ခဲ့သည်။ သံချေးတက်နှုန်းသည် ထူးကဲသည်။ အကာအကွယ်မဲ့ သံမဏိသည် ရက်သတ္တပတ်အနည်းငယ်အတွင်း သိသာထင်ရှားစွာ ယိုယွင်းပျက်စီးသည်။ အပေါ်ယံလွှာစနစ်များသည် 350–450 µm DFT ထက် မကြာခဏ ကျော်လွန်ပြီး သွပ်ကြွယ်ဝသော အောက်ခံအလွှာများ၊ အထူထပ်မြင့် အလယ်အလွှာများနှင့် အထူးပြု polysiloxane သို့မဟုတ် aliphatic polyurethane အပေါ်ဆုံးအလွှာများကို ပေါင်းစပ်ထားသည်။ ဤစနစ်များကို ISO 12944-9 (ယခင်က ပင်လယ်ပြင်အတွက် NORSOK M-501) မှ အုပ်ချုပ်ပြီး စမ်းသပ်ခြင်းသည် တင်းကျပ်ပြီး ကြာရှည်သည်။.
လျှောက်ထားနိုင်သော နယ်ပယ်များ- ISO 12944 သည် အဘယ်အရာကို အကျုံးဝင်ပြီး အကျုံးမဝင်သနည်း
အင်ဂျင်နီယာများ နားလည်ရမည့် အရေးကြီးသော ကွဲပြားမှုတစ်ခု- ISO 12944 သည် ဖွဲ့စည်းတည်ဆောက်ပုံဆိုင်ရာ သံမဏိနှင့် အကာအကွယ်ကိုယ်ထည်များကို အကျုံးဝင်သည်—အတွင်းပိုင်း လျှပ်စစ်အစိတ်အပိုင်းများကို မဟုတ်ပါ။.
ISO 12944 သည် အဘယ်အရာကို အကျုံးဝင်သနည်း။
- သံမဏိ ဖွဲ့စည်းတည်ဆောက်ပုံဆိုင်ရာ မူဘောင်များ (တံတားများ၊ မျှော်စင်များ၊ စက်မှုအဆောက်အအုံများ)
- သံမဏိ လျှပ်စစ်အကာအကွယ်/ဗီရို ကိုယ်ထည်များ
- သံမဏိ တပ်ဆင်ပန်းကန်ပြားများ၊ ကေဘယ်လ်ဗန်းများနှင့် အထောက်အပံ့များ
- အပြင်ဘက် သံမဏိပစ္စည်း အိမ်ရာများ
ISO 12944 သည် အဘယ်အရာကို အကျုံးမဝင်သနည်း။
- အကာအကွယ်အတွင်းရှိ Terminal block များ၊ ချိတ်ဆက်ကိရိယာများနှင့် လျှပ်ကူးပစ္စည်းများ – ၎င်းတို့သည် လျှပ်စစ်ဖြင့် သတ္တုပြားချခြင်း (tin, silver, gold) သို့မဟုတ် IEC 60068-2-11 ဆားငွေ့မှုန် စမ်းသပ်ခြင်း သို့မဟုတ် NEMA/IP အဆင့်သတ်မှတ်ချက်များအရ ပစ္စည်းရွေးချယ်ခြင်း (stainless steel 316L, nickel-plated copper, PA66 plastic) ကို အသုံးပြုသည်
- Circuit breaker များ (MCB များ၊ MCCB များ) – အတွင်းပိုင်း သတ္တုပြားချခြင်း + ပစ္စည်းသိပ္ပံဖြင့် ကာကွယ်ထားပြီး ဆေးသုတ်ခြင်း မဟုတ်ပါ
- contactors များနှင့် relays များ – သတ္တုပြားချခြင်း သတ်မှတ်ချက်များ (ကြေးနီပေါ်တွင် လျှပ်စစ်ဖြင့် သတ္တုပြားချထားသော သံဖြူ သို့မဟုတ် ငွေ) + တံဆိပ်ခတ်ထားသော အိမ်ရာ (IP54/IP55) ကို အားကိုးသည်
- မည်သည့် လျှပ်ကူးပစ္စည်းမဆို – လျှပ်စီးကြောင်း သယ်ဆောင်သည့် terminal သို့ အီပေါ့ဆီဆေး ရာနှင့်ချီသော မိုက်ခရိုမီတာများ လိမ်းခြင်းသည် လျှပ်ကာပြိုကွဲခြင်း သို့မဟုတ် ထိတွေ့မှု ခုခံအား ကျရှုံးခြင်းကို ဖြစ်စေနိုင်သည်
ဤကွဲပြားမှုသည် အဘယ်ကြောင့် အရေးကြီးသနည်း။ Terminal block များ သို့မဟုတ် MCB များအတွက် “ISO 12944 C5 အပေါ်ယံလွှာ” ကို သတ်မှတ်ခြင်းသည် နည်းပညာအရ မမှန်ကန်ဘဲ လက်တွေ့မကျပါ။ ဤအစိတ်အပိုင်းများသည် မတူညီသော စံနှုန်းများကို လိုက်နာသည်-
- IEC 60068-2-11 – ဆားငွေ့မှုန် စမ်းသပ်ခြင်း (96 သို့မဟုတ် 1000 နာရီ)
- NEMA အမျိုးအစား အဆင့်သတ်မှတ်ချက်များ – အကာအကွယ် ပတ်ဝန်းကျင် ကာကွယ်ရေး
- IP အဆင့်သတ်မှတ်ချက်များ – ဝင်ရောက်မှု ကာကွယ်ရေး (ဖုန်မှုန့်/အစိုဓာတ်)
- အစိတ်အပိုင်းအဆင့် သတ္တုပြားချခြင်း သတ်မှတ်ချက်များ – IEC 60068-2-50 အရ အလွှာအထူ၊ ကပ်ညှိမှု၊ မာကျောမှု
အမှန်တကယ် ဝယ်ယူမှုတွင်- လျှပ်စစ်ဗီရိုတစ်ခု အကာအကွယ်ကိုယ်ထည် ကို “ISO 12944 C4-M” (ကမ်းရိုးတန်းစက်မှု၊ အလယ်အလတ် တာရှည်ခံမှု) ဟု သတ်မှတ်နိုင်သည်။ အတွင်းပိုင်းရှိ အစိတ်အပိုင်းများ ထိုအကာအကွယ် (Terminal block များ၊ MCB များ၊ VIOX သို့မဟုတ် ပြိုင်ဘက်များထံမှ contactor များ) ကို ၎င်းတို့၏ သတ္တုပြားချခြင်း အထူ၊ ပစ္စည်းအဆင့်နှင့် IP အဆင့်သတ်မှတ်ချက်ဖြင့် သီးခြားစီ သတ်မှတ်ထားသည်—ISO 12944 ဖြင့် မဟုတ်ပါ။.
တာရှည်ခံမှု သက်တမ်းအဆင့်များ- ပြုပြင်ထိန်းသိမ်းမှု စက်ဝန်းများ စီစဉ်ခြင်း
ISO 12944 ဘာသာစကားအရ တာရှည်ခံမှုသည် အာမခံချက်မဟုတ်ပါ။ ၎င်းသည် ပထမအကြိမ် အဓိက ပြုပြင်ထိန်းသိမ်းမှု ဆေးသုတ်ခြင်း မလိုအပ်မချင်း မျှော်မှန်းထားသော အချိန် ဖြစ်သည်။ ၎င်းကို အာမခံချက်မဟုတ်ဘဲ ပြုပြင်ထိန်းသိမ်းမှု စီစဉ်ခြင်းဆိုင်ရာ ကန့်သတ်ချက်တစ်ခုအဖြစ် မှတ်ယူပါ။ အပေါ်ယံလွှာသည် ဥရောပစကေးတွင် Ri3 သို့ရောက်ရှိသောအခါ (မျက်စိဖြင့်မြင်နိုင်သော မျက်နှာပြင် သံချေးတက်ခြင်း၏ 5–10% ခန့်)၊ အဓိက ပြုပြင်ထိန်းသိမ်းမှုကို စတင်သည်။.
အနိမ့် (L): 7 နှစ်အထိ
အကောင်းဆုံးအတွက်- မိုးလုံလေလုံ C1 အသုံးချမှုများ၊ ကာကွယ်ထားသော သံချေးတက်မှုနည်းသော ပတ်ဝန်းကျင်များ သို့မဟုတ် ယာယီဖွဲ့စည်းပုံများ
ပုံမှန်စနစ်- တစ်ထပ် acrylic သို့မဟုတ် alkyd (60–100 µm DFT)
ပိုင်ဆိုင်မှု၏ စုစုပေါင်းကုန်ကျစရိတ်- ရှေ့ဦးစွာ အနိမ့်ဆုံး၊ မကြာခဏ ပြန်လည်အပေါ်ယံလွှာတင်ခြင်း
အလယ်အလတ် (M): 7–15 နှစ်
အကောင်းဆုံးအတွက်- ကျေးလက် C2 နှင့် မြို့ပြ C3 အဆောက်အဦများတွင် ပြုပြင်ထိန်းသိမ်းမှု ဘတ်ဂျက် အသင့်အတင့်ရှိခြင်း
ပုံမှန်စနစ်- Epoxy အောက်ခံအလွှာ + acrylic အပေါ်ဆုံးအလွှာ (120–180 µm DFT)
အသုံးချခြင်း- စက်မှုစက်ရုံများစွာသည် ကုန်ကျစရိတ်နှင့် သက်တမ်းကို ဤနေရာတွင် ချိန်ညှိကြသည်။.
အမြင့် (H): 15–25 နှစ်
အကောင်းဆုံးအတွက်- C4 ကမ်းရိုးတန်းစက်မှုလုပ်ငန်းများ၊ ကြမ်းတမ်းသောပတ်ဝန်းကျင် လျှပ်စစ်အကာအကွယ်များ၊ ဝင်ရောက်ရန်ခက်ခဲသော ပစ္စည်းများ
ပုံမှန်စနစ်- သွပ်ကြွယ်ဝသော အီပေါ့ဆီ + အထူထပ်မြင့် အီပေါ့ဆီ + polyurethane (200–280 µm DFT)
အသုံးချခြင်း- စိန်ခေါ်မှုရှိသော ပတ်ဝန်းကျင်ရှိ VIOX လျှပ်စစ်အစိတ်အပိုင်းများသည် မကြာခဏ အမြင့်ဆုံး တာရှည်ခံမှုကို သတ်မှတ်သည်။.
အလွန်အမြင့် (VH): 25 နှစ်ထက်ပို၍
အကောင်းဆုံးအတွက်- C5–CX အလွန်ပြင်းထန်သော ပတ်ဝန်းကျင်များ၊ အရေးကြီးသော အခြေခံအဆောက်အအုံများ၊ ပင်လယ်ပြင် ဖွဲ့စည်းပုံများ
ပုံမှန်စနစ်- အဆင့်မြင့် အလွှာပေါင်းစုံစနစ်များ၊ သွပ်ကြွယ်ဝသော အီပေါ့ဆီ၊ အလွှာပေါင်းစုံ အီပေါ့ဆီ အလယ်အလွှာများ၊ အထူးပြု အပေါ်ဆုံးအလွှာ (300–450 µm DFT)
အသုံးချခြင်း- ပင်လယ်ပြင် လေအားလျှပ်စစ်ပလက်ဖောင်းများ၊ အရေးကြီးသော ဓာတုပစ္စည်းစက်ရုံများ၊ ပင်လယ်ရေအောက် အခြေခံအဆောက်အအုံ
ဓာတ်ခွဲခန်း စမ်းသပ်ခြင်း- ဓာတ်ခွဲခန်းမှ အမှန်တကယ်ကမ္ဘာသို့
ISO 12944-6 defines how coating systems are validated. Tests simulate environmental stressors—salt spray, humidity cycling, UV, temperature swings—to predict real-world performance.
Atmospheric Test Program (C2 Through C5)
For C2–C5 categories, testing includes:
| Test Method | C2 Low | C3 Medium | C4 High | C5 V.High | ရည်ရွယ်ချက် |
| Humidity Condensation (ISO 6270-1) | 48–120 h | 120–480 h | 120–720 h | 480–1200 h | Simulates morning dew, indoor condensation, salt creep |
| Neutral Salt Spray (ISO 9227) | အနည်းငယ်မျှသာ | 240 h | 480–720 h | 720–1440 h | Simulates coastal salt-air attack |
| Water Immersion (ISO 2812-2) | အနည်းငယ်မျှသာ | အနည်းငယ်မျှသာ | အနည်းငယ်မျှသာ | အနည်းငယ်မျှသာ | Identifies osmotic blistering risk |
| Cyclic Aging (Appendix B) | တစ်ခုမှ | တစ်ခုမှ | တစ်ခုမှ | 1680–2400 h | Combines UV, humidity, salt spray, temperature cycling |
A C5 Very High durability system must endure 480 hours of condensation, 1440 hours of salt spray, and 1680 hours of cyclic aging—totaling over 3600 cumulative test hours. This is the reason very high durability systems cost 2–3× more than medium durability systems.
Immersion Test Program (Im1–Im3 for Buried or Wet Components)
အဘို့ ကေဘယ်ဂလင်းများ and components in submersed or wet service:
| Immersion Category | Water Type | မြင့်မားသောကြာရှည်ခံမှု | V. High Durability | လျှောက်လွှာ |
| Im1 | Fresh water (rivers) | 3000 h immersion + 1440 h condensation | 4000 h + 2160 h | Hydroelectric, dam facilities |
| Im2 | Seawater (no cathodic protection) | 3000 h immersion + 1440 h salt spray | 4000 h + 2160 h | Submerged marine structures |
| Im3 | Soil (buried pipelines) | 3000 h immersion + 1440 h salt spray | 4000 h + 2160 h | Underground electrical ducts |
Paint Systems and Dry Film Thickness (DFT)

ISO 12944-5 prescribes the coating systems for each corrosivity and durability combination. Dry Film Thickness (DFT) is critical: it is the dried coating thickness measured in micrometers (µm). Thicker is not always better—adhesion matters—but DFT is the primary lever for durability.
Typical Multi-Coat Systems
C1 Low:
- System: Single-coat acrylic
- Primer: None
- Topcoat: Acrylic (80 µm)
- Coats: 1
- Total DFT: 80 µm
C3 Medium (Industrial Standard):
- System: Zinc epoxy + polyurethane
- Primer: Zinc-rich epoxy (100 µm)
- Intermediate: Epoxy (80 µm)
- Topcoat: Polyurethane UV-resistant (80 µm)
- Coats: 3
- Total DFT: 260 µm
C5 Very High (Harsh Industrial):
- System: Heavy-duty epoxy + polysiloxane
- Primer: Zinc-rich epoxy (120 µm)
- Intermediate 1: High-build epoxy (120 µm)
- အလယ်အလတ်အလွှာ ၂: အထူထပ် epoxy (100 µm)
- အပေါ်ဆုံးအလွှာ: Aliphatic polyurethane သို့မဟုတ် polysiloxane (80–100 µm)
- အလွှာအရေအတွက်: 4–5
- စုစုပေါင်း DFT: 420–440 µm
အလွှာတစ်ခုစီတွင် လုပ်ဆောင်ချက်တစ်ခုစီရှိသည်: သွပ်ကြွယ်ဝသော primer သည် သံမဏိကိုကာကွယ်ရန် (galvanic protection) မိမိကိုယ်ကိုစတေးသည်၊ အလယ်အလတ်အလွှာများသည် အထူနှင့် UV ခံနိုင်ရည်ကိုတည်ဆောက်ပေးပြီး အပေါ်ဆုံးအလွှာသည် တောက်ပမှု၊ ရာသီဥတုဒဏ်ခံနိုင်ရည်နှင့် စတေးခံမျက်နှာပြင်ကိုပေးသည်။.
Real-World Applications များ

ကမ်းရိုးတန်းစက်မှုဇုန်ရှိ လျှပ်စစ်အကာအကွယ် (C4)
ပင်လယ်အငန်ဓာတ်အသင့်အတင့်ရှိသော ဆိပ်ကမ်းအနီးရှိ သင်္ဘောကျင်းတစ်ခုပေါ်တွင် တပ်ဆင်ထားသော သံမဏိလျှပ်စစ်ထိန်းချုပ်မှုအိမ်သည် တစ်နှစ်ပတ်လုံး ဆားငွေ့မှုန်များကို ရင်ဆိုင်နေရသည်။ အိမ်ကိုယ်ထည် (တည်ဆောက်ပုံဆိုင်ရာသံမဏိဘောင်နှင့် ဘေးဘောင်များ) သည် C4 တိုက်စားမှုကို ခံနိုင်ရည်ရှိသည်။ သတ်မှတ်သူသည် ရွေးချယ်သည်။ C4-M (အလယ်အလတ်ကြာရှည်ခံမှု၊ ၅-၇ နှစ်) အိမ်ကိုယ်ထည်အတွက်။.
အိမ်ကိုယ်ထည် သတ်မှတ်ချက် (ISO 12944): သွပ်ကြွယ်ဝသော epoxy primer (80 µm) + epoxy အလယ်အလတ်အလွှာ (100 µm) + polyurethane အပေါ်ဆုံးအလွှာ (80 µm) = စုစုပေါင်း DFT 260 µm။ စမ်းသပ်မှုတွင် ၄၈၀ နာရီ ဆားငွေ့မှုန်ဖြန်းခြင်း၊ ၂၄၀ နာရီ စိုထိုင်းဆအငွေ့ပျံခြင်းတို့ပါဝင်သည်။ ပြုပြင်ထိန်းသိမ်းမှုအချိန်ဇယား: နှစ်စဉ်စစ်ဆေးပါ၊ အဓိကမျက်နှာပြင်များကို ၅-၇ နှစ်တစ်ကြိမ် ပြန်လည်ဆေးသုတ်ပါ။.
အတွင်းပိုင်းအစိတ်အပိုင်းများ (ISO 12944 မဟုတ်ပါ): ဤအိမ်အတွင်း၌ VIOX terminal လုပ်ကွက်များ, MCB circuit breakers, DIN ရထားလမ်းနှင့် contactors များ ကို သီးခြားစီသတ်မှတ်ထားသည်:
- Terminal blocks: IEC 60068-2-11 (အနည်းဆုံး 96h ဆားငွေ့မှုန်) အရ သံဖြူဖြင့်ပြုလုပ်ထားသော ကြေးနီ terminals
- MCB များ- လျှပ်စစ်ဖြင့်ပြုလုပ်ထားသော ငွေ သို့မဟုတ် သံဖြူအဆက်အသွယ်များ၊ IP54 အလုံပိတ်အိမ်
- DIN rail: အဆက်အသွယ်ဧရိယာများအတွက် နီကယ်လ်ဖြင့်ပြုလုပ်ထားသော သွပ်ရည်စိမ်သံမဏိ
- Contactors: နီကယ်လ်ဖြင့်ပြုလုပ်ထားသော ကြေးနီအဆက်အသွယ်များ၊ NEMA Type 3R အရ အလုံပိတ်ကွိုင်
အိမ်ကိုယ်ထည်သည် အတွင်းပိုင်းအစိတ်အပိုင်းများကို ကာကွယ်ပေးသည်; အစိတ်အပိုင်းများသည် အထူဆေးသုတ်အလွှာများမဟုတ်ဘဲ လျှပ်စစ်ဖြင့်ပြုလုပ်ခြင်း/ပစ္စည်းသိပ္ပံကို အသုံးပြုသည်။.
ပင်လယ်ပြင်အောက်ခံအဆောက်အဦ: ဆေးသုတ်ထားသော သံမဏိ (C5–CX)
ပင်လယ်ပြင်လေအားလျှပ်စစ်ထုတ်ယူသည့်စက်ရုံအတွက် အထောက်အပံ့ဘောင်သည် အမြဲတမ်းအငန်ဓာတ်မြင့်မားသောရေမှုန်များ၊ အလွန်အမင်းစိုထိုင်းဆနှင့် UV တို့နှင့်ထိတွေ့သော တည်ဆောက်ပုံဆိုင်ရာသံမဏိဖြင့် ဖွဲ့စည်းထားသည်။ တိုက်စားမှုအမျိုးအစား: CX (အလွန်ပြင်းထန်). ဒီဇိုင်းသက်တမ်းလိုအပ်ချက်: ၂၅+ နှစ်။.
တည်ဆောက်ပုံဆိုင်ရာသံမဏိ သတ်မှတ်ချက် (ISO 12944): C5-VH သို့မဟုတ် CX-VH စနစ်။ သွပ်ကြွယ်ဝသော epoxy (120 µm) + အထူထပ် epoxy အလယ်အလတ်အလွှာနှစ်ခု (တစ်ခုလျှင် 100 µm) + polysiloxane အပေါ်ဆုံးအလွှာ (100 µm) = စုစုပေါင်း DFT 420 µm။ စမ်းသပ်မှုတွင် ၁၄၄၀ နာရီ ဆားငွေ့မှုန်ဖြန်းခြင်း၊ ၄၈၀ နာရီ စိုထိုင်းဆအငွေ့ပျံခြင်းနှင့် ၁၆၈၀ နာရီ စက်ဝန်းအိုမင်းခြင်းတို့ပါဝင်သည်။ ဤသတ်မှတ်ချက်သည် ဝယ်ယူမှုကို မောင်းနှင်သည်: တည်ဆောက်ပုံဆိုင်ရာ ဂဟေဆက်ခြင်း၊ အမြန်ချိတ်များနှင့် မျက်နှာပြင်အားလုံးသည် ဤတင်းကျပ်သော အပေါ်ယံလွှာစံနှုန်းနှင့် ကိုက်ညီရမည်။.
Cable နှင့် Connector ထည့်သွင်းမှုများ (ISO 12944 မဟုတ်ပါ): အဆောက်အဦမျက်နှာပြင်ရှိ လျှပ်စစ်ချိတ်ဆက်မှုများ—ကေဘယ်ဂလင်းများ, waterproof connectors, junction boxes—ကို သတ်မှတ်သည်:
- Cable glands: Stainless steel 316L ကိုယ်ထည်၊ လျှပ်စစ်ဖြင့်ပြုလုပ်ထားသော ကြေးဝါချည်မျှင်များ၊ ဆီလီကွန် သို့မဟုတ် EPDM တံဆိပ်များ
- ရေစိုခံ connectors: ငွေဖြင့်ပြုလုပ်ထားသော အဆက်အသွယ်များ၊ stainless steel အိမ်များ၊ IP67/IP68 အဆင့်သတ်မှတ်ချက်
- Junction boxes: နီကယ်လ်ဖြင့်ပြုလုပ်ထားသော အတွင်းပိုင်း terminals ပါသော stainless steel သို့မဟုတ် အမှုန့်ဖြင့်ဖုံးအုပ်ထားသော သံမဏိကိုယ်ထည် (C5 အပြင်ပိုင်း)
ဆေးသုတ်ထားသော သံမဏိအဆောက်အဦ (ISO 12944) နှင့် အလုံပိတ်၊ လျှပ်စစ်ဖြင့်ပြုလုပ်ထားသော လျှပ်စစ်အစိတ်အပိုင်းများ (IEC စံနှုန်းများ) သည် စနစ်တစ်ခုအနေဖြင့် အတူတကွအလုပ်လုပ်သည်။.
အစားအစာထုတ်လုပ်သည့်စက်ရုံ: မိုးလုံလေလုံ စိုထိုင်းဆမြင့်မားသောပတ်ဝန်းကျင် (C3)
အစားအစာထုတ်လုပ်သည့်စက်ရုံအတွင်း၌ အတွင်းပိုင်းစိုထိုင်းဆသည် အလွန်မြင့်မားသည်; ရေ/အငွေ့ရည်များသည် စက်ပစ္စည်းများကို ပုံမှန်ဖုံးအုပ်ထားသည်။ အနီးအနားရှိ ယာဉ်အသွားအလာမှ SO₂ ပမာဏသည် နည်းပါးသည်။ အမျိုးအစားခွဲခြားခြင်း: C3 (အလယ်အလတ်တိုက်စားနိုင်မှု).
တည်ဆောက်ပုံ/တပ်ဆင်ခြင်း သံမဏိ သတ်မှတ်ချက် (ISO 12944): စက်ပစ္စည်းဘောင်များ၊ အထောက်အပံ့များနှင့် ထိတွေ့ထားသော သံမဏိမျက်နှာပြင်များကို C3-M (၇-၁၅ နှစ်ကြာရှည်ခံမှု) အထိ ဆေးသုတ်ထားသည်။ သတ်မှတ်ချက်: သွပ်ကြွယ်ဝသော epoxy primer (100 µm) + epoxy အလယ်အလတ်အလွှာ (80 µm) + polyurethane အပေါ်ဆုံးအလွှာ (80 µm) = စုစုပေါင်း 260 µm။ စမ်းသပ်မှုတွင် ၂၄၀ နာရီ ဆားငွေ့မှုန်ဖြန်းခြင်း (အစားအစာကိုင်တွယ်ခြင်းမှ hygroscopic ဆားများကိုပုံစံတူပြုလုပ်ခြင်း)၊ ၁၂၀ နာရီ စိုထိုင်းဆအငွေ့ပျံခြင်းတို့ပါဝင်သည်။.
လျှပ်စစ်အစိတ်အပိုင်းများ (ISO 12944 မဟုတ်ပါ): ဤပတ်ဝန်းကျင်အတွင်းရှိ ထိန်းချုပ်ကိရိယာများ (VIOX သို့မဟုတ် အခြားထုတ်လုပ်သူများမှ) ပါဝင်သည်။ modular contactors, terminal blocks နှင့် sensors များ။ ၎င်းတို့ကို ကာကွယ်ထားသည်:
- Stainless steel သို့မဟုတ် နီကယ်လ်ဖြင့်ပြုလုပ်ထားသော ကြေးနီ terminals (အစားအစာအဆင့်ပစ္စည်းများ)
- အလုံပိတ်ကွိုင် epoxy-sealed windings ပါသော အကာအကွယ်များ (အနည်းဆုံး IP54) (ဆေးမသုတ်ထားပါ)
- ပလတ်စတစ် (PA66 သို့မဟုတ် POM) ကာကွယ်ပစ္စည်းအစိတ်အပိုင်းများ၊ မူလကပင် တိုက်စားမှုကိုခံနိုင်ရည်ရှိသည်
ဆေးသုတ်ထားသော သံမဏိဘောင်သည် လျှပ်စစ်အကာအကွယ်များအတွင်း၌ ခြောက်သွေ့သောပတ်ဝန်းကျင်ကို ထိန်းသိမ်းထားသည်; အတွင်းပိုင်းအစိတ်အပိုင်းများသည် ပစ္စည်းသိပ္ပံနှင့် အလုံပိတ်အိမ်ကို အသုံးပြုသည်။.
မကြာခဏမေးမေးခွန်းများ
မေးခွန်း ၁: ကြာရှည်ခံမှုသည် အာမခံနှင့်တူညီပါသလား။
မဟုတ်ပါ။ ကြာရှည်ခံမှုသည် နည်းပညာဆိုင်ရာ စီမံကိန်းဆွဲသည့်အချက်ဖြစ်သည်—အချိန်ကာလအထိ ပထမဆုံးအဓိကပြုပြင်ထိန်းသိမ်းမှု လိုအပ်သည်။ ၁၅ နှစ်ကြာရှည်ခံသောစနစ်တွင် ၁၀ နှစ်အာမခံရှိနိုင်သည်၊ အဘယ်ကြောင့်ဆိုသော် အာမခံတွင် အန္တရာယ်လွှဲပြောင်းခြင်းနှင့် တာဝန်ယူမှုတို့ပါဝင်သည်။ ကြာရှည်ခံမှုသည် ပြုပြင်ထိန်းသိမ်းမှုကို စီစဉ်ရန်ကူညီသည်; အာမခံသည် တရားဝင်/စီးပွားဖြစ်အာမခံချက်ဖြစ်သည်။.
မေးခွန်း ၂: ကျွန်ုပ်၏ပတ်ဝန်းကျင်သည် C3 သို့မဟုတ် C4 ဖြစ်ကြောင်း မည်သို့သိနိုင်မည်နည်း။
C3 ညွှန်ကိန်းများ: မြို့ပြ/စက်မှုလေထု၊ ရံဖန်ရံခါ မိုးလုံလေလုံအငွေ့ပျံခြင်း၊ အပျော့စား SO₂ အနံ့၊ ဆားငန်ဓာတ်နည်းပါးခြင်း သို့မဟုတ် ပင်လယ်နှင့်အဆက်အသွယ်မရှိခြင်း။.
C4 ညွှန်ကိန်းများ: ကမ်းရိုးတန်းဒေသ၊ ဆားငွေ့များ မကြာခဏထိတွေ့မှု၊ စိုထိုင်းဆ အမြဲရှိနေခြင်း၊ အကာအကွယ်မဲ့ သံမဏိများတွင် ၁-၂ လအတွင်း သိသာသော သံချေးတက်ခြင်း။.
ဒေသအလိုက် သံချေးတက်နှုန်းပြမြေပုံများကို ကြည့်ရှုပါ (နိုင်ငံအလိုက် စံချိန်စံညွှန်းအဖွဲ့အစည်းများစွာက ထုတ်ဝေသည်) သို့မဟုတ် ဒေသဆိုင်ရာ ကျွမ်းကျင်မှုရှိသော အပေါ်ယံအလွှာ ပစ္စည်းပေးသွင်းသူကို ဆက်သွယ်ပါ။ VIOX သည် သင်၏ စက်ရုံတည်နေရာနှင့် ပုံစံပေါ်မူတည်၍ အကြံပေးနိုင်သည်။.
မေးခွန်း ၃: C5 ပတ်ဝန်းကျင်တွင် C3 စနစ်ကို အသုံးပြု၍ ငွေကုန်သက်သာနိုင်ပါသလား။
Technically, yes. Practically, no. A C3 system (260 µm DFT, 3 coats) will show heavy rust and require maintenance within 1–2 years in a C5 environment (where 5+ years is the baseline expectation). The apparent savings vanish in recoating labor and operational downtime. Specify the correct category upfront.
မေးခွန်း ၄: DFT ဆိုသည်မှာ အဘယ်နည်း၊ အဘယ်ကြောင့် အရေးကြီးသနည်း။
ခြောက်သွေ့သောအလွှာအထူ (DFT) ဆိုသည်မှာ မိုက်ခရိုမီတာဖြင့် တိုင်းတာသော ခြောက်သွေ့ပြီးနောက် အပေါ်ယံအလွှာ၏ အထူဖြစ်သည်။ ၎င်းသည် အဓိက တာရှည်ခံနိုင်မှု အားကိုးရာဖြစ်သည်။. အလွှာထူလေ သံချေးတက်ခြင်းမှ ကာကွယ်မှု ပိုကြာလေဖြစ်သည်။ DFT ကို အသုံးပြုနေစဉ် စိုစွတ်သောအလွှာအထူ တိုင်းတာသည့်ကိရိယာများဖြင့် စစ်ဆေးပြီး အပြီးသတ် ကုသပြီးနောက် ခြောက်သွေ့သောအလွှာအထူ တိုင်းတာသည့်ကိရိယာများဖြင့် အတည်ပြုသည်။ ဖျက်ဆီးခြင်းမရှိသော စမ်းသပ်ခြင်းသည် လိုက်နာမှုကို သေချာစေသည်။.
မေးခွန်း ၅: အပေါ်ယံအလွှာပါသော စက်ပစ္စည်းများကို မည်မျှ မကြာခဏ စစ်ဆေးသင့်သနည်း။
C1 ပတ်ဝန်းကျင်များ: ၃-၅ နှစ်တစ်ကြိမ်။.
C2–C3 ပတ်ဝန်းကျင်များ: ၁-၂ နှစ်တစ်ကြိမ်။.
C4–CX ပတ်ဝန်းကျင်များ: နှစ်စဉ် သို့မဟုတ် နှစ်နှစ်တစ်ကြိမ်။.
အက်ကွဲကြောင်းငယ်များ၊ ကပ်ငြိမှုဆုံးရှုံးခြင်း သို့မဟုတ် သံချေးစွန်းထွက်ခြင်းတို့ကို စောစီးစွာ ရှာဖွေတွေ့ရှိခြင်းသည် ကြီးမားသော ပြုပြင်ထိန်းသိမ်းမှု မစတင်မီ အစက်အပြောက် ပြုပြင်မှုများ ပြုလုပ်နိုင်စေသည်။ ပုံမှန်စစ်ဆေးခြင်းသည် အပေါ်ယံအလွှာ၏ သက်တမ်းကို တိုးစေပြီး ပိုင်ဆိုင်မှု၏ စုစုပေါင်းကုန်ကျစရိတ်ကို လျှော့ချပေးသည်။.
သော့ထုတ်ယူမှုများ
ISO 12944 သည် နှစ်ဝင်ရိုးမူဘောင်တစ်ခုဖြစ်သည်: သံချေးတက်နိုင်မှု အမျိုးအစား (C1–CX) သည် ပတ်ဝန်းကျင်၏ ပြင်းထန်မှုကို သတ်မှတ်သည်။ တာရှည်ခံနိုင်မှုအဆင့် (L, M, H, VH) သည် ပြုပြင်ထိန်းသိမ်းမှု ကြားကာလကို သတ်မှတ်သည်။.
သင်၏ ပတ်ဝန်းကျင်ကို သိပါ: ကမ်းရိုးတန်း C4 စက်ရုံကို C3 အဖြစ် မှားယွင်းစွာ ခွဲခြားသတ်မှတ်ခြင်းသည် အချိန်မတိုင်မီ ပျက်စီးခြင်းနှင့် ကုန်ကျစရိတ်ကြီးသော အရေးပေါ်ဆေးသုတ်ခြင်းကို ဖြစ်ပေါ်စေသည်။ ဒေသအလိုက် သံချေးတက်နှုန်းပြမြေပုံများနှင့် ဒေသဆိုင်ရာ ကျွမ်းကျင်မှုများကို အသုံးပြုပါ။.
DFT သည် တာရှည်ခံနိုင်မှု အားကိုးရာဖြစ်သည်: အလွှာထူလေ ပိုကြာရှည်ခံလေဖြစ်သည်။ မှန်ကန်သော DFT ကို ကြိုတင်သတ်မှတ်ပါ။ အသုံးပြုနေစဉ် လျှော့မတွက်ပါနှင့်။ လက်ခံခြင်းမပြုမီ စမ်းသပ်ခြင်းဖြင့် အတည်ပြုပါ။.
အလွှာပေါင်းစုံစနစ်များကို အင်ဂျင်နီယာနည်းဖြင့် တည်ဆောက်ထားသည်: အလွှာတစ်ခုစီ—အောက်ခံဆေး၊ ကြားခံဆေး၊ အပေါ်ဆုံးဆေး—သည် သီးခြားလုပ်ဆောင်ချက်တစ်ခုကို လုပ်ဆောင်သည်။ အစားမထိုးပါနှင့်။ ခိုင်ခံ့မှုသည် စနစ်တစ်ခုလုံးပေါ်တွင် မူတည်သည်။.
တာရှည်ခံနိုင်မှုသည် စီမံကိန်းရေးဆွဲခြင်းကိရိယာတစ်ခုဖြစ်သည်: ၎င်းကို အာမခံချက်အဖြစ်မဟုတ်ဘဲ ပြုပြင်ထိန်းသိမ်းမှုကာလများနှင့် ဘတ်ဂျက်များကို သတ်မှတ်ရန်အတွက် အသုံးပြုပါ။ ပြုပြင်ထိန်းသိမ်းမှု ကြိမ်နှုန်းသည် တိကျသော အမျိုးအစားခွဲခြားမှုအပေါ် မူတည်သည်။.
နယ်ပယ်ရှင်းလင်းမှု—ISO 12944 သည် အတွင်းပိုင်း လျှပ်စစ်အစိတ်အပိုင်းများမဟုတ်ဘဲ ဖွဲ့စည်းတည်ဆောက်ပုံ သံမဏိနှင့် အကာအရံကိုယ်ထည်များနှင့် သက်ဆိုင်သည်: စံနှုန်းသည် သံမဏိဖွဲ့စည်းပုံများနှင့် ဗီရိုအပြင်ပိုင်းများအတွက် ဆေးသုတ်စနစ်များကို သတ်မှတ်သည်။ အကာအရံများအတွင်းရှိ တစ်ဦးချင်း လျှပ်စစ်အစိတ်အပိုင်းများ (ဂိတ်ဆက်တုံးများ၊ MCB များ၊ ကွန်တက်တာများ) သည် လျှပ်စစ်ဖြင့် သတ္တုရည်စိမ်ခြင်း (သံဖြူ၊ ငွေ၊ ရွှေ)၊ ပစ္စည်းရွေးချယ်မှု (သံမဏိ၊ PA66) နှင့် တံဆိပ်ခတ်ထားသော အိမ်ရာ (IP အဆင့်သတ်မှတ်ချက်များ) ကို အားကိုးပြီး IEC 60068-2-11 နှင့် NEMA အမျိုးအစား အဆင့်သတ်မှတ်ချက်များကဲ့သို့ စံနှုန်းများကို လိုက်နာသည်။ ဤကာကွယ်မှုနည်းဗျူဟာနှစ်ခုကို ရောထွေးခြင်းသည် အတွေ့အကြုံရှိသော လျှပ်စစ်အင်ဂျင်နီယာများက ချက်ချင်း အလံထောင်မည့် အသုံးအနှုန်းအမှားတစ်ခုဖြစ်သည်။.
ဗီရိုဒီဇိုင်းသည် အဆင့်နှစ်ဆင့်စနစ်ဖြစ်သည်: ဟိ အကာအကွယ်ကိုယ်ထည် အကာအကွယ်အတားအဆီးတစ်ခုကို ဖန်တီးပေးသော ISO 12944 (ဆေးသုတ်/အပေါ်ယံအလွှာ) ကို လိုက်နာသည်။ အတွင်းပိုင်းရှိ အစိတ်အပိုင်းများ လက်ရှိသယ်ဆောင်သည့် အစိတ်အပိုင်းများကို ကာကွယ်ပေးသော လျှပ်စစ်စံနှုန်းများ (သတ္တုရည်စိမ်ခြင်း/ပစ္စည်း/တံဆိပ်ခတ်ခြင်း) ကို လိုက်နာပါ။ နှစ်ခုစလုံးကို မှန်ကန်စွာ သတ်မှတ်ရမည်ဖြစ်သော်လည်း ၎င်းတို့သည် လုံးဝကွဲပြားခြားနားသော စနစ်များဖြစ်သည်။.
VIOX ထုတ်ကုန်များနှင့် ISO 12944: VIOX ကေဘယ်ဂလင်းများ ရေစိုခံချိတ်ဆက်ကိရိယာများကို နယ်နိမိတ်တွင် မကြာခဏအသုံးပြုလေ့ရှိသည်—ISO 12944 ဆေးသုတ်ထားသော ဗီရိုနံရံများမှတဆင့် တပ်ဆင်ခြင်း။ ထိုအခြေအနေတွင် ဤဝင်ပေါက်အစိတ်အပိုင်းများကို IEC 60068-2-11 (ဆားငွေ့မှုန် စမ်းသပ်ခြင်း) နှင့် IP အဆင့်သတ်မှတ်ချက်များအရ သတ်မှတ်ထားသည်။ VIOX terminal လုပ်ကွက်များ, MCBs, contactors များနှင့် DIN ရထားလမ်း ဗီရိုအတွင်းပိုင်းသည် ၎င်းတို့၏ကိုယ်ပိုင်စံနှုန်းများ (အစိတ်အပိုင်းအဆင့် သတ္တုရည်စိမ်ခြင်း၊ ထိတွေ့ပစ္စည်း၊ တံဆိပ်ခတ်ထားသော အိမ်ရာ)—ISO 12944 မဟုတ်ပါ။.
နိဂုံး
သံချေးတက်ခြင်းသည် သူ့အလိုလို ကြေငြာခြင်းမရှိပါ။ မြင်နိုင်သော သံချေးများ ပေါ်လာချိန်တွင် ပျက်စီးမှုသည် စတင်နေပြီဖြစ်သည်။ ISO 12944 သည် ခန့်မှန်းခြေကို တိကျမှုအဖြစ် ပြောင်းလဲပေးပြီး သင်၏ ပတ်ဝန်းကျင်နှင့် ဘတ်ဂျက်နှင့် ကိုက်ညီသော အပေါ်ယံအလွှာများကို သတ်မှတ်ရန်အတွက် ပြန်လုပ်နိုင်သော မူဘောင်တစ်ခုကို ပေးသည်။.
သင်သည် C2 ကျေးလက်ဂိုဒေါင်တစ်ခု သို့မဟုတ် C5 ကမ်းလွန်ပလက်ဖောင်းတစ်ခုကို ကာကွယ်နေသည်ဖြစ်စေ စံနှုန်းသည် ရှင်းလင်းသောလမ်းကြောင်းတစ်ခုကို ပေးသည်: သင်၏ ပတ်ဝန်းကျင်ကို တိုင်းတာပါ၊ သင်၏ တာရှည်ခံနိုင်မှုအဆင့်ကို ရွေးချယ်ပါ၊ အပေါ်ယံအလွှာစနစ်ကို သတ်မှတ်ပါ၊ သင့်လျော်သော စမ်းသပ်မှုများကို ပြုလုပ်ပါ၊ အသုံးပြုနေစဉ် DFT ကို အတည်ပြုပါ။ ရလဒ်မှာ ရည်ရွယ်ထားသော ဒီဇိုင်းသက်တမ်းအတွက် ရှင်သန်ပြီး ကြီးပွားတိုးတက်သော စက်ပစ္စည်းဖြစ်သည်။.
သင်၏ လျှပ်စစ်စနစ်များအတွက် သံချေးကာကွယ်မှုကို သတ်မှတ်ရာတွင် လမ်းညွှန်မှု လိုအပ်ပါသလား။ VIOX အင်ဂျင်နီယာများသည် သင်၏ လိုအပ်ချက်များကို ISO 12944 အမျိုးအစားများနှင့် ညှိနှိုင်းပေးပြီး အကြံပြုနိုင်သည် terminal လုပ်ကွက်များ, ကေဘယ်လ်ဖြေရှင်းနည်းများနှင့် သင်၏ ပတ်ဝန်းကျင်နှင့် သင့်လျော်သော ထိန်းချုပ်အစိတ်အပိုင်းများ။ နည်းပညာဆိုင်ရာ အကြံဉာဏ်အတွက် ဆက်သွယ်ပါ။. ကြှနျုပျတို့ကိုဆကျသှယျရနျ ကမ်းရိုးတန်း C4 ထိတွေ့မှု ၃-၄ နှစ်အကြာတွင် လိမ္မော်ရောင် သံချေးတက်ခြင်းနှင့် ဆေးသုတ်ခြင်းများ ပြနေသော သံချေးတက်နေသော လျှပ်စစ်ဗီရိုအကာအရံကို အနီးကပ်ရိုက်ထားသောပုံ.