Your server room electrical cabinet is packed tighter than a rush-hour subway car. MCBs, RCCB, pelindung lonjakan arus, terminal blocks—every millimeter of that 35mm DIN rail is occupied. Then the fire safety auditor walks in, points at your panel, and asks the question you’ve been avoiding: “Where’s the fire suppression?”
You glance at the cramped enclosure. There’s no room for a traditional extinguisher cylinder. The budget doesn’t cover piped gas systems. And the thought of water anywhere near live 480V circuits makes your stomach drop.
Here’s the solution you didn’t know existed: an 18mm-wide fire suppression device that mounts directly on your DIN rail, activates automatically when temperature hits 170°C, and floods the cabinet with fire-killing aerosol in under 6 seconds. No external power required. No piping. No compromise on space.
Welcome to the 1P DIN rail solid aerosol generator—the fire suppressor that fits where nothing else can.
What Is a 1P DIN Rail Solid Aerosol Generator?
A 1P DIN rail solid aerosol generator is a compact, self-contained fire suppression unit designed to protect small enclosed electrical spaces up to 0.1 m³—roughly the volume of a standard 600mm × 400mm × 400mm breaker panel.
The “1P” designation tells you everything about its form factor: one pole position. That’s approximately 18mm wide, the exact same footprint as a standard single-pole miniature circuit breaker. You can literally mount it on the DIN rail right next to your MCBs and contactors.

How It Works: Solid Chemistry, No Pressure
Unlike traditional fire extinguishers that rely on pressurized cylinders or piped delivery networks, solid aerosol generators stay non-pressurized until the moment of activation.
Inside the sealed housing sits a solid propellant compound—typically potassium-based. Think of it like a controlled chemical flare. When a thermal sensor detects cabinet temperatures around 170°C (the typical activation threshold), it triggers an exothermic reaction. The solid compound burns in a controlled manner, generating:
- Ultra-fine aerosol particles (1-2 microns)—primarily potassium salts and carbonates
- Inert gases (nitrogen, CO₂)—which pressurize the discharge and slightly dilute oxygen
The reaction completes in under 6 seconds. The aerosol cloud floods the protected volume, attacking the fire at a molecular level.
Key specs at a glance:
| Parameter | Typical Value |
| Lebar | 18mm (1P modular) |
| Pemasangan | 35mm DIN rail (EN 60715) |
| Aktivasi | Thermal (no power needed) |
| Trigger temp | 170°C |
| Discharge time | ≤ 6 seconds |
| Agent mass | 10g (protects ~0.1 m³) |
| Kehidupan pelayanan | Up to 10 years |
| Operating range | -50°C to +90°C |
Pro-Tip: The 170°C activation temperature is critical. It’s high enough to avoid false triggers in poorly ventilated panels (even in 50°C ambient conditions), but low enough to catch electrical fires sebelumnya plastics fully ignite and release toxic fumes.
Why Aerosol for Electrical Cabinets? “The No-Pipe Advantage”
Electrical cabinets present a fire suppression problem that traditional methods can’t solve elegantly. They’re enclosed, densely packed with energized components, and often located where access is limited.
The Problem: Traditional Suppression Doesn’t Fit
Water and foam? Conductive, corrosive, catastrophic. A sprinkler activation might put out the fire, but it’ll also destroy every piece of electronics in the panel—and probably the panels next to it.
Gas systems (CO₂, FM-200, Novec)? Effective, but they require:
- Pressurized storage cylinders (taking up valuable floor space)
- Distribution piping (expensive to install, requires panel penetrations)
- Pressure monitoring (maintenance overhead)
- Significant upfront cost
Untuk kabinet listrik tunggal 0,5 m³, menentukan sistem gas yang dipipakan seperti menyewa buldoser untuk menggali lubang pot bunga. Mampu secara teknis? Tentu. Masuk akal secara ekonomi? Sama sekali tidak.
Alat pemadam portabel di dekatnya? Hanya berguna jika:
- Seseorang hadir saat kebakaran dimulai
- Mereka terlatih untuk menggunakannya
- Mereka bersedia mendekati panel listrik yang terbakar
- Mereka dapat membuka pintu kabinet tanpa terkena api
Semoga berhasil dengan keempatnya pada pukul 2 pagi di hari Minggu.
Solusi Aerosol: Ringkas, Otonom, Aman Secara Elektrik
Generator aerosol padat memecahkan masalah ini dengan pendekatan yang sangat berbeda:
1. Penekanan non-konduktif secara elektrik
Agen aerosol secara eksplisit dirancang agar tidak menghantarkan listrik (sesuai ISO 15779). Tidak akan terjadi korsleting atau kerusakan pada elektronik sensitif. Setelah api padam dan aerosol mengendap, peralatan sering kali dapat melanjutkan pengoperasian setelah diperiksa dan dibersihkan—tidak perlu penggantian grosir.
2. Tidak diperlukan infrastruktur
Setiap generator benar-benar mandiri. Prosedur instalasi:
- Jepitkan ke rel DIN (pemasangan klip tanpa alat)
- Arahkan kabel probe termal ke lokasi strategis
- Selesai
Tidak ada jalur pipa. Tidak ada bejana tekan. Tidak ada ruang penekanan khusus. Waktu pemasangan diukur dalam menit, bukan hari.
3. Banjir total untuk ruang tertutup
Partikel aerosol tetap tersuspensi selama beberapa menit, menciptakan atmosfer pemadam kebakaran di seluruh volume kabinet. Bahkan jika api tersembunyi di balik bundel kabel atau blok terminal, aerosol tetap mencapainya.
Alat pemadam tradisional membutuhkan garis pandang. Aerosol tidak peduli di mana api berada.
4. Operasi otonom—tanpa daya, tidak masalah
Sistem aktivasi termal berfungsi apakah bangunan memiliki daya atau tidak. Generator tidak peduli apakah itu pukul 3 sore pada hari Selasa atau pukul 3 pagi saat Natal. Ketika interior kabinet mencapai 170°C, penekanan diaktifkan. Tidak ada baterai. Tidak ada sirkuit kontrol. Tidak ada ketergantungan.
Pro-Tip: Untuk aplikasi penting, Anda dapat mengintegrasikan output alarm kontak kering tambahan ke BMS Anda. Generator masih beroperasi secara independen, tetapi pemberitahuan jarak jauh memungkinkan Anda mengirim pemeliharaan sebelum kerusakan peralatan menjadi luas.
Bagaimana Penekanan Api Aerosol Padat Sebenarnya Bekerja
Jika Anda belum pernah menemukan teknologi aerosol padat, mekanismenya terdengar hampir seperti fiksi ilmiah: senyawa padat berubah menjadi awan pembunuh api dalam hitungan detik, tanpa penyimpanan bertekanan. Inilah kimianya, tanpa basa-basi pemasaran.
Reaksi Kimia: Dari Padat ke Aerosol
Di dalam generator terdapat kartrid yang tertutup rapat yang diisi dengan propelan padat—biasanya senyawa berbasis kalium seperti kalium nitrat yang dicampur dengan bahan bakar organik dan pengikat. Ketika sensor termal trip pada 170°C, ia memulai reaksi eksotermik terkontrol.
Propelan tidak meledak. Itu terbakar, seperti suar yang terbakar lambat atau granat asap. Pembakaran ini menghasilkan dua output penting:
- Ultra-fine aerosol particles (diameter 1-2 mikron)—terutama garam dan karbonat kalium
- Inert gases (nitrogen dan CO₂) —yang memberikan tekanan internal untuk merusak membran pelepasan dan menyebarkan aerosol
Seluruh reaksi selesai dalam waktu kurang dari 6 detik. Membran pelepasan pecah, dan awan putih tebal membanjiri volume yang dilindungi.
Mekanisme Penekanan: Interupsi Rantai Kimia
Penekanan aerosol menyerang api pada dua tingkatan—tetapi mekanisme utamanya adalah kimia murni.
Primer: Pembersihan radikal bebas (penghambatan kimia)
Api bukan hanya “bahan bakar + oksigen + panas.” Ini adalah reaksi berantai yang melibatkan radikal bebas—fragmen molekul yang sangat reaktif seperti H·, OH·, dan O·. Radikal ini menyebarkan pembakaran dengan memecah molekul bahan bakar dan menghasilkan lebih banyak radikal dalam lingkaran yang berkelanjutan.

Partikel kalium dari aerosol mencegat dan berikatan dengan radikal penting pembakaran ini, membentuk senyawa yang stabil dan tidak reaktif:
- K· + OH· → KOH (kalium hidroksida)
- K· + O· → KO (kalium oksida)
Dengan rantai radikal terputus, pembakaran tidak dapat mempertahankan diri. Api padam—bahkan jika bahan bakar dan oksigen masih ada.
Ini pada dasarnya berbeda dari:
- Menghambat (yang tidak termasuk oksigen)
- Pendinginan (yang menghilangkan panas)
Aerosol menyerang kimia api pada tingkat molekuler. Itulah mengapa ia membutuhkan massa agen yang jauh lebih sedikit daripada sistem CO₂ atau gas inert.
Sekunder: Penyerapan panas dan pengenceran oksigen
Awan aerosol juga menyerap panas radiasi dari api, mengurangi energi pembakaran. Gas-gas inert (N₂, CO₂) yang dihasilkan selama reaksi mengencerkan konsentrasi oksigen sekitar 2-3%—tidak cukup untuk tidak aman bagi orang, tetapi cukup untuk membuat penyalaan ulang lebih sulit.
Suspensi dan Pencegahan Penyalaan Ulang: “Atmosfer Penekanan”
Tidak seperti CO₂ (yang menghilang dengan cepat) atau air (yang mengalir pergi), partikel aerosol tetap tersuspensi di udara selama beberapa menit. Ini menciptakan apa yang saya sebut “Atmosfer Penekanan”—awan pelindung yang bertahan lama yang mencegah penyalaan ulang saat kabinet mendingin.
Bahkan jika komponen yang membara mencoba menyala kembali 60 detik setelah penekanan awal, aerosol masih ada, siap untuk menyerang radikal bebas baru.
Pro-Tip: Setelah pelepasan, ventilasi area tersebut sebelum masuk kembali. Meskipun aerosol tidak beracun (disetujui untuk ruang yang biasanya ditempati per EPA SNAP), lingkungan pasca-pelepasan akan memiliki visibilitas yang berkurang dan partikulat halus di udara. Kenakan masker debu selama pembersihan dan inspeksi—paru-paru Anda akan berterima kasih.

Di Mana Generator Aerosol 1P Sebenarnya Digunakan
Perangkat ini dibuat khusus untuk ruang listrik kecil dan tertutup di mana kebakaran dapat meningkat dalam hitungan detik tetapi penekanan tradisional tidak praktis atau tidak mungkin.
1. Kabinet distribusi listrik dan switchgear
Panel MCCB, switchboard tegangan rendah, pusat kendali motor. Di mana pun Anda memiliki komponen berenergi dalam kotak logam tertutup.
2. Rak server dan peralatan telekomunikasi
Pusat data, stasiun pangkalan menara seluler, node komputasi tepi. Elektronik kepadatan tinggi di mana air bukan pilihan dan ruang sangat berharga.
3. Inverter surya dan penutup penyimpanan baterai
Inverter fotovoltaik, kabinet BESS, stasiun pengisian daya EV. Peralatan berenergi tinggi dalam instalasi luar ruangan atau semi-luar ruangan di mana akses terbatas dan suhu sekitar berayun liar.
4. Panel kontrol industri
Kabinet PLC, penutup VFD, peralatan SCADA di pabrik, kilang, dan pabrik pengolahan. Kontrol penting yang tidak mampu mengalami downtime.
5. Stasiun transformator kecil dan saluran kabel
Kompartemen transformator step-down, kotak sambungan kabel, peralatan lemari besi bawah tanah. Ruang terbatas di mana respons kebakaran manual tertunda atau berbahaya.
Benang merahnya? Volume tertutup di bawah 1 m³, peralatan penting, dan nol toleransi untuk kerusakan air. Jika anggaran pemadaman kebakaran Anda ketat dan kabinet Anda kecil, generator aerosol sering kali menjadi hanya solusi hemat biaya yang benar-benar berfungsi.
Ukuran Generator Aerosol Anda: Metode 3 Langkah
Memilih generator aerosol yang tepat bermuara pada tiga perhitungan dan satu keputusan instalasi. Inilah metodenya.
Langkah 1: Hitung Volume Internal Kabinet
Ukur internal dimensi penutup Anda—bukan dimensi label eksternal. Kurangi ketebalan dinding (biasanya 1,5-2mm untuk kabinet lembaran logam standar).
Formula: Volume (m³) = Lebar (m) × Tinggi (m) × Kedalaman (m)
Contoh: Kabinet 600mm × 400mm × 250mm (dimensi eksternal):
Internal: ~596mm × 396mm × 246mm
0,596 × 0,396 × 0,246 = 0,058 m³
Bulatkan menjadi 0,06 m³ untuk margin keamanan.
Langkah 2: Terapkan Kepadatan Desain
Generator aerosol diukur berdasarkan massa agen per volume yang dilindungi. Standar industri untuk perlindungan banjir total di kabinet listrik adalah sekitar 100 g/m³.
Formula: Massa agen yang dibutuhkan (g) = Volume (m³) × Kepadatan desain (100 g/m³)
Untuk contoh 0,06 m³ kami: 0,06 × 100 = 6 g
Jadi sebuah Generator 10g (seperti VIOX QRR0.01G/S) memberikan cakupan yang memadai dengan margin keamanan yang sehat (~67% di atas minimum).
Langkah 3: Perhitungkan Halangan dan Aliran Udara
Jika kabinet Anda memiliki bundel kabel yang padat, partisi padat, atau sirkulasi udara internal yang buruk, Anda perlu mengimbanginya:
- Opsi A: Beberapa generator yang lebih kecil. Posisikan unit untuk mencakup zona yang berbeda. Misalnya, dua generator 10g untuk kabinet 0,15 m³ dengan partisi tengah yang padat.
- Opsi B: Tingkatkan massa agen sebesar 20-30%. Gunakan unit tunggal yang lebih besar untuk mengatasi tantangan distribusi.
- Opsi C: Penempatan probe strategis. Posisikan probe termal di dekat area rawan kebakaran yang diketahui: bus bar, transformator, terminal arus tinggi, titik masuk kabel.
Langkah 4: Posisikan Probe Termal Seperti Profesional
Sebagian besar generator 1P dilengkapi dengan probe termal ganda (atas dan bawah). Berikut adalah tempat untuk meletakkannya:
- Probe atas: Pasang di dekat titik tertinggi tempat gas panas menumpuk—biasanya atap kabinet, tepat di atas bus bar atau komponen berdaya tinggi.
- Probe bawah: Posisikan di dekat sumber penyulutan potensial di bagian dasar—transformator, blok terminal beban tinggi, kelenjar masuk kabel.
Udara panas naik, tetapi gangguan listrik dapat berasal dari mana saja. Probe ganda memastikan cakupan terlepas dari lokasi kebakaran.
Pro-Tip: Jika kabinet Anda memiliki “titik panas” yang diketahui—katakanlah, transformator yang berjalan pada 80°C di bawah beban normal—posisikan probe dalam jarak 10cm darinya. Jangan hanya mengandalkan konveksi untuk membawa panas ke sensor yang jauh. Deteksi langsung selalu lebih cepat.
Tabel Ukuran Referensi Cepat
| Volume Kabinet | Massa Agen Minimum | Produk yang Direkomendasikan |
| Hingga 0,1 m³ | 10g | VIOX QRR0.01G/S (1P) |
| 0,1 – 0,3 m³ | 30g | Unit rel yang lebih besar atau 3× unit 10g |
| 0,3 – 1,0 m³ | 100g | Aerosol industri (non-DIN rail) |
| Lebih dari 1,0 m³ | Kustom | Sistem rekayasa atau penekanan gas |
Untuk kabinet di atas 1,0 m³: Pertimbangkan sistem aerosol rekayasa atau penekanan agen bersih konvensional. Generator DIN rail dioptimalkan untuk kecil enklosur di mana metode tradisional tidak masuk akal secara ekonomi.
Instalasi: Lebih Mudah Daripada Memasang MCB
Memasang generator aerosol 1P lebih sederhana dari yang Anda kira. Jika Anda dapat memasang pemutus sirkuit, Anda dapat memasang salah satu dari ini.
Instalasi Perangkat Keras (5 menit)
- Pasang generator pada rel DIN TS35 35mm
Klip pegas terintegrasi langsung terpasang pada rel. Tidak diperlukan alat. Tidak ada pengencang. Cukup tekan dan klik. - Rute kabel probe termal
Kabel probe standar panjangnya 10cm. Panjang khusus hingga 50cm tersedia jika Anda perlu menjangkau titik panas tertentu. Rute satu probe ke bagian atas kabinet, satu ke bagian bawah (atau di dekat komponen berisiko tinggi yang diketahui). - Pemasangan alternatif (jika ruang rel DIN terbatas)
Lapisan perekat 3M tersedia sebagai opsi khusus. Bersihkan permukaan pemasangan, kupas, tempel. Selesai.
Komisioning (0 menit)
Tidak ada komisioning. Tidak ada pemrograman. Tidak ada koneksi listrik.
Setelah dipasang, generator segera beralih ke siaga operasional. Ia memantau suhu terus menerus melalui elemen termal pasif—tanpa baterai, tanpa catu daya, tanpa dependensi.
Aktivasi dan Penggantian
Aktivasi adalah otomatis dan tidak dapat diubah. Ketika suhu kabinet mencapai 170°C, unit akan mengeluarkan isinya. Setelah pengeluaran, unit harus diganti—ini adalah perangkat sekali pakai yang dirancang untuk satu kejadian aktivasi.
Anggap saja seperti kantung udara mobil: Anda berharap tidak pernah membutuhkannya, tetapi jika Anda membutuhkannya, ia hanya berfungsi sekali dan kemudian diganti.
Pertimbangan Operasional:
- Dirancang untuk ruang tertutup yang biasanya tidak berpenghuni
- Aerosol tidak beracun dan aman bagi lingkungan (ODP/GWP nol)
- Pengeluaran menciptakan awan partikulat padat yang untuk sementara mengurangi jarak pandang
- Ruang tertutup harus disegel dengan baik untuk mempertahankan konsentrasi penekanan
- Setelah pengeluaran, ventilasi selama beberapa menit sebelum masuk kembali
- Peralatan biasanya dapat diperiksa dan dikembalikan ke layanan setelah mengikuti protokol pasca-kebakaran standar
Pro-Tip: Tandai tanggal pemasangan pada rumah generator dengan spidol permanen. Meskipun masa pakai dinilai hingga 10 tahun, Anda pasti ingin melacak usia untuk perencanaan penggantian. Atur pengingat kalender pada tahun ke-9.
Standar & Sertifikasi: Apa yang Harus Dicari
Penekanan api aerosol adalah teknologi yang diatur. Saat menentukan generator rel DIN 1P, pastikan generator tersebut memenuhi standar ini—jangan hanya percaya pada perkataan pabrikan.
Standar Amerika Utara
NFPA 2010 (Sistem Pemadam Kebakaran Aerosol Tetap)
Standar pemasangan utama di Amerika Utara. Mendefinisikan persyaratan desain, pemasangan, pengujian, dan pemeliharaan. Jika Anda bekerja dengan AHJ (petugas pemadam kebakaran, penjamin emisi asuransi, inspektur bangunan) yang berbasis di AS, kepatuhan terhadap NFPA 2010 sering kali tidak dapat dinegosiasikan.
UL 2775 / ULC-S508
Standar keselamatan produk Underwriters Laboratories untuk unit sistem pemadam aerosol terkondensasi. Produk yang terdaftar di UL telah menjalani pengujian independen untuk:
- Kinerja penekanan api
- Keamanan listrik
- Dampak lingkungan
- Keandalan dalam kondisi yang dinyatakan
Pencantuman UL tidak diwajibkan secara hukum, tetapi semoga berhasil mendapatkan persetujuan asuransi tanpanya.
Standar Internasional
ISO 15779:2011 (Sistem Pemadam Kebakaran Aerosol Terkondensasi)
Standar internasional yang mencakup persyaratan, metode pengujian, dan rekomendasi keselamatan. Yang diperbarui ISO/DIS 15779.2 revisi sedang berlangsung pada tahun 2025, dengan perkiraan publikasi pada tahun 2026.
EN 15276-1 (Sistem Pemadam Kebakaran Tetap – Sistem Pemadam Aerosol Terkondensasi)
Standar Eropa untuk komponen dan pemasangan sistem aerosol. Diperlukan untuk penandaan CE di pasar UE.
Persetujuan Lingkungan
Persetujuan EPA SNAP
Program Kebijakan Alternatif Baru Signifikan Badan Perlindungan Lingkungan AS. Mensertifikasi agen aerosol sebagai aman untuk digunakan di ruang berpenghuni dengan:
- Nol potensi penipisan ozon (ODP = 0)
- Dapat diabaikan potensi pemanasan global (GWP < 1)
- Tidak ada persistensi atmosfer jangka panjang
Persetujuan SNAP berarti agen tersebut tidak akan berkontribusi pada penipisan lapisan ozon atau perubahan iklim—penting jika perusahaan Anda memiliki tujuan lingkungan.
Apa Artinya Ini bagi Pengadaan
Jika Anda menentukan untuk proyek dengan pengawasan peraturan:
- Amerika Utara: Membutuhkan Pencantuman UL 2775 + Kepatuhan terhadap NFPA 2010
- Eropa: Membutuhkan Kepatuhan terhadap EN 15276-1 + Penandaan CE
- Proyek internasional: Carilah Kepatuhan ISO 15779
Pro-Tip: Selalu minta dokumen sertifikasi dan manual pemasangan sebelumnya pesanan pembelian. Jika produsen tidak dapat memberikan laporan pengujian pihak ketiga dari laboratorium yang diakui (UL, FM Approvals, VdS, LPCB), tinggalkan. “Memenuhi ISO 15779” dan “Diuji sesuai ISO 15779” adalah klaim yang sangat berbeda.
Kesimpulan: Pemadam Kebakaran yang Cocok di Tempat yang Tidak Bisa Dimasuki Orang Lain
Inilah kenyataan tentang kebakaran kabinet listrik: jarang terjadi, tetapi ketika terjadi, Anda mengukur waktu respons dalam hitungan detik, bukan menit. Bus bar arc, terminal yang kelebihan beban, belitan transformator yang gagal—salah satu dari ini dapat menyulut insulasi dan berubah menjadi kebakaran yang menghabiskan kabinet bahkan sebelum Anda mendapatkan pemberitahuan alarm.
Metode penekanan tradisional menghadapi kebenaran yang pahit:
- Air menghancurkan apa yang tidak dihancurkan oleh api
- Sistem gas pipa harganya lebih mahal daripada peralatan yang mereka lindungi (untuk kabinet kecil)
- Alat pemadam portabel membutuhkan kehadiran dan intervensi manusia
Generator aerosol padat rel DIN 1P memecahkan masalah ini dengan kesederhanaan yang elegan:
- 18mm ruang rel
- 10 gram propelan padat
- Nol ketergantungan eksternal
- 170°C pemicu termal
- 6 detik hingga pelepasan penuh
- 10 tahun kewaspadaan diam
Tanpa pipa. Tanpa silinder. Tanpa isi ulang tahunan. Tanpa catu daya. Tanpa komisioning. Cukup jepitkan pada rel, posisikan probe termal, dan lupakan sampai tanggal pembuatan mengatakan sudah waktunya untuk mengganti.
Jika Anda menentukan kabinet listrik untuk aplikasi penting—ruang server, ladang surya, stasiun telekomunikasi, kontrol industri—tanyakan pada diri sendiri: dapatkah Anda membayar tidak untuk melindunginya?
Generator aerosol 10g harganya lebih murah daripada satu panggilan layanan darurat. Penggantian kabinet setelah kebakaran? Itu adalah waktu henti berminggu-minggu dan biaya penggantian lima angka, minimal. Ditambah penyelidikan, klaim asuransi, penjelasan kepada manajemen tentang mengapa peralatan penting tidak dilindungi.
Matematikanya tidak rumit. Keputusan seharusnya juga tidak.
Siap melindungi kabinet listrik Anda? Jelajahi Generator Aerosol Padat Rel DIN 1P Seri QRR0.01G/S VIOX—direkayasa khusus untuk aplikasi dengan ruang terbatas di mana keandalan bukanlah opsional. Hubungi tim teknis kami untuk panduan ukuran, dukungan pemasangan, dan dokumentasi sertifikasi.
Butuh bantuan dengan instalasi tertentu? Teknisi aplikasi kami dapat meninjau tata letak kabinet Anda dan merekomendasikan penempatan generator dan pemosisian probe yang optimal. Hubungi melalui formulir kontak atau hubungi hotline teknis kami.