VOB4-63 MCB – Miniature Circuit Breaker

  • Dual Breaking Capacity: 6000A or 10000A – superior fault protection for industrial systems
  • Enhanced Insulation: AC 500V rated insulation voltage (higher than standard 415V)
  • Dual Standard Compliance: IEC 60898-1 & IEC 60947-2 certified for both residential and industrial applications
  • Complete Rating Range: 1A to 63A in full increments (1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 13A, 16A, 20A, 25A, 32A, 40A, 50A, 63A)
  • All Trip Curves Available: Type B, C, D curves for any application requirement
  • Daya Tahan Industri: 10,000 mechanical operations, 4,000 electrical cycles
  • Instalasi Profesional: DIN rail mounting, 1-25mm² terminal capacity
  • Proven Quality: Manufactured by ISO 9001:2015 certified VIOX Electric

Kirimkan kebutuhan Anda, kami akan mengutip untuk Anda dalam waktu 12 jam

VOB4-63 High-Performance Miniature Circuit Breaker

Industrial-Grade MCB with 6kA/10kA Breaking Capacity – VIOX VOB4-63 series miniature circuit breakers deliver superior protection for demanding commercial and industrial installations. Dual-standard compliant (IEC 60898-1 & IEC 60947-2), thermal-magnetic trip technology, 500V insulation rating, complete range from 1A to 63A.

Why Choose VOB4-63 High-Performance MCB?

  • Dual Breaking Capacity: 6000A or 10000A – superior fault protection for industrial systems
  • Enhanced Insulation: AC 500V rated insulation voltage (higher than standard 415V)
  • Dual Standard Compliance: IEC 60898-1 & IEC 60947-2 certified for both residential and industrial applications
  • Complete Rating Range: 1A to 63A in full increments (1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 13A, 16A, 20A, 25A, 32A, 40A, 50A, 63A)
  • All Trip Curves Available: Type B, C, D curves for any application requirement
  • Daya Tahan Industri: 10,000 mechanical operations, 4,000 electrical cycles
  • Instalasi Profesional: DIN rail mounting, 1-25mm² terminal capacity
  • Proven Quality: Manufactured by ISO 9001:2015 certified VIOX Electric

Complete Technical Specifications

Parameter Spesifikasi
Product Series VOB4-63
Kapasitas Pemutusan (Icn) 6000A or 10000A
Jumlah Kutub 1P, 2P, 3P, 4P
Nilai Arus (Dalam) 1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 13A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Nilai Tegangan Operasional 1P: 240V/415V~
2P, 3P, 4P: 415V~
Trip Unit Technology Termal-magnetik
Curve Code (Trip Characteristics) B, C, D (all curves available)
Tegangan Isolasi Terukur (Ui) AC 500V~ (enhanced)
Nilai Tegangan Tahan Impuls (Uimp) 4000V
Daya Tahan Mekanis 10.000 siklus
Daya Tahan Listrik 4,000 cycles
Mengencangkan Torsi M5 2.5N·m ⚠
IP Degree of Protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Ambient Air Temperature for Operation -5°C hingga +40°C
Kepatuhan terhadap Standar IEC 60898-1 & IEC 60947-2
EU RoHS Directive Compliant EU RoHS Declaration
Tingkat Polusi 2 conforming to IEC/EN 60898-1
Kapasitas Terminal Upper/Lower Wiring: 1-25mm² (flexible/rigid conductor)
Pemasangan 35mm DIN rail (IEC/EN 60715)

Understanding Breaking Capacity: 6kA vs 10kA

The VOB4-63 series offers two breaking capacity options to match your installation requirements:

6kA Breaking Capacity (6000A)

  • Terbaik untuk: Residential buildings, small commercial offices, light industrial facilities
  • Instalasi umum: Lighting circuits, small motor loads, general power distribution
  • Fault current handling: Up to 6,000 amperes short-circuit protection

10kA Breaking Capacity (10000A) – Recommended for Industrial

  • Terbaik untuk: Industrial plants, large commercial buildings, high-power equipment installations
  • Instalasi umum: Motor control centers, industrial automation, heavy machinery protection
  • Fault current handling: Up to 10,000 amperes short-circuit protection
  • Additional safety margin: 67% higher capacity than 6kA for demanding applications

How to Choose: Calculate your installation’s prospective short-circuit current (PSC). For most industrial applications with transformers above 200kVA, 10kA breaking capacity is recommended.


Trip Curve Selection Guide

Select the correct trip curve based on your load characteristics:

Type B Curve MCB (3-5 × In)

Best for resistive loads with minimal inrush current:

  • Residential and commercial lighting circuits
  • Heating elements and resistive heaters
  • Domestic appliances
  • Long cable runs where trip sensitivity is needed

Type C Curve MCB (5-10 × In) – Most Common

Best for general-purpose commercial and industrial applications:

  • Motor-driven equipment (pumps, fans, compressors)
  • Fluorescent and LED lighting with electronic ballasts
  • Transformers and inductive loads
  • Sistem HVAC
  • General power distribution panels

Type D Curve MCB (10-20 × In)

Best for high inrush current loads:

  • Large industrial motors and motor starters
  • Welding equipment and X-ray machines
  • Large transformers with high magnetizing inrush
  • Capacitive loads
  • Industrial machinery with high starting currents

Applications by Industry

Manufaktur Industri

  • Motor control centers (MCCs) for production equipment
  • CNC machines and industrial automation systems
  • Conveyor systems and material handling equipment
  • Industrial robots and automated assembly lines
  • Power distribution in factory electrical panels

Bangunan Komersial

  • Office building main and sub-distribution boards
  • Shopping mall electrical systems
  • Hotel and hospitality power distribution
  • Data center electrical protection
  • Commercial HVAC and mechanical systems

Infrastructure & Construction

  • Public building electrical installations
  • Educational facilities (schools, universities)
  • Healthcare facilities (hospitals, clinics)
  • Transportation hubs (airports, train stations)
  • Government and municipal buildings

Energy & Utilities

  • Solar PV system protection circuits
  • Wind turbine electrical systems
  • Power generation auxiliary equipment
  • Electrical substations and switchgear
  • Energy storage system protection

OEM & Panel Builders

  • Electrical panel manufacturers and switchgear assemblers
  • Control system integrators
  • Industrial equipment manufacturers
  • Automation system providers
  • Custom electrical solution designers

Dimensions & Installation Data

Modular Width (Standard 18mm Module):

  • 1P: 1 module (17.8mm)
  • 2P: 2 modules (35.6mm)
  • 3P: 3 modules (53.4mm)
  • 4P: 4 modules (71.2mm)

Dimensi Fisik:

  • Height: 83mm
  • Depth: 74mm (1P), 63.5mm (multi-pole)
  • DIN rail depth: 35mm

Instalasi:

  • Mounting: Standard 35mm DIN rail per IEC/EN 60715
  • Terminal type: Screw terminals (torque-controlled)
  • Wire capacity: 1-25mm² (both stranded and solid conductors)
  • Connection: Top and bottom terminals for daisy-chain wiring
VOB4-63 Dimension
Figure 2: VOB4-63 precise dimensional drawings for panel layout and DIN-rail mounting

Certifications & Quality Standards

Kepatuhan Standar Internasional

IEC 60898-1: Household and similar installations (residential, light commercial)
IEC 60947-2: Industrial low-voltage switchgear and controlgear
EN 60898-1: European standard for MCB performance
Pollution Degree 2: Suitable for standard industrial environments

Manufacturing Quality

ISO 9001:2015 Certified: Quality management system certified
EU RoHS Compliant: Lead-free, environmentally responsible manufacturing
Factory Testing: 100% electrical testing before shipment
Traceability: Full batch tracking and quality documentation

Third-Party Verification

✓ Independent laboratory testing for breaking capacity verification
✓ Type testing per IEC standards
✓ Continuous production monitoring


VOB4-63 vs VOB3-63: Which MCB Should You Choose?

Fitur VOB3-63 VOB4-63
Kapasitas Putus 4.5kA / 6kA 6kA / 10kA
Insulation Voltage 415V~ 500V~
Standar IEC 60898-1 IEC 60898-1 & 60947-2
Recommended Use Residential, Light Commercial Industrial, Heavy Commercial
Titik Harga Ekonomi Premi

Choose VOB4-63 when:

  • Working in industrial environments with higher fault currents
  • Protecting high-value equipment requiring maximum safety margin
  • Compliance with IEC 60947-2 is required
  • Long-term reliability in demanding conditions is critical

Why VIOX Electric for Your MCB Supply?

Direct Manufacturer Advantages

  • Factory-direct pricing without middleman markup
  • Consistent quality control throughout production
  • Flexible MOQ for both small orders and bulk projects
  • Custom labeling and OEM partnership available

Dukungan Teknis

  • Pre-sales engineering consultation
  • Application-specific recommendations
  • Dokumentasi teknis dalam berbagai bahasa
  • After-sales technical support

Global Supply Capability

  • ISO 9001:2015 certified manufacturing facility
  • Capacity for large-volume orders
  • Reliable delivery schedules
  • International shipping experience

Rangkaian Produk

  • Complete MCB ratings from 1A to 63A
  • All pole configurations (1P, 2P, 3P, 4P)
  • All trip curves (B, C, D)
  • Both breaking capacities (6kA, 10kA)

How to Order VOB4-63 MCB

Model Numbering System: VOB4-63 [Breaking Capacity] [Poles] [Curve] [Rating]

Contoh:

  • VOB4-63 10kA 3P C 32A – 10kA, 3-Pole, Type C curve, 32A rated current
  • VOB4-63 6kA 2P C 16A – 6kA, 2-Pole, Type C curve, 16A rated current
  • VOB4-63 10kA 4P D 63A – 10kA, 4-Pole, Type D curve, 63A rated current

Ordering Information Checklist:

  1. Breaking capacity required (6kA or 10kA)
  2. Number of poles (1P, 2P, 3P, 4P)
  3. Trip curve type (B, C, or D)
  4. Rated current (1A to 63A)
  5. Jumlah yang dibutuhkan
  6. Delivery timeline

Get Your Quote Today

Contact VIOX Electric – MCB Manufacturer

For Distributors & Volume Orders:

  • Competitive volume pricing tiers
  • Distributor partnership programs
  • Co-branding and private labeling options
  • Technical training and support

For Panel Builders & OEM:

  • Engineering sample requests
  • Custom specifications available
  • CAD drawings and technical documentation
  • Integration support

For Electrical Contractors:

  • Project-specific quotations
  • Mixed order flexibility
  • Fast delivery for urgent projects
  • Dukungan aplikasi teknis

Pertanyaan yang Sering Diajukan (FAQ)

Q: What’s the difference between 6kA and 10kA breaking capacity?
A: The breaking capacity indicates the maximum short-circuit current the MCB can safely interrupt. 10kA provides 67% more protection than 6kA, making it essential for industrial installations with higher fault current levels.

Q: Can VOB4-63 replace my existing MCB?
A: Yes, VOB4-63 is DIN-rail compatible and follows standard modular sizing. Ensure the breaking capacity, voltage rating, and pole configuration match your application requirements.

Q: What’s the lead time for bulk orders?
A: Standard lead time is 2-4 weeks depending on order quantity and specifications. Contact our sales team for urgent orders.

Q: Do you provide technical documentation?
A: Yes, complete technical datasheets, CAD drawings, installation manuals, and certificates are provided with every order.

Q: What’s your MOQ (Minimum Order Quantity)?
A: We accommodate both small sample orders and large-volume projects. Contact us for specific MOQ based on your requirements.


Related VIOX Circuit Protection Products

  • MCCB Series (Molded Case Circuit Breakers): For higher ratings up to 1600A and breaking capacities up to 100kA
  • RCCB/RCBO: Add earth leakage protection with residual current devices
  • ACB Series (Air Circuit Breakers): Main distribution circuit breakers for large facilities
  • Load Break Switches: Manual isolation and switching up to 125A
  • SPD (Surge Protection Devices): Lightning and surge protection

[VIEW ALL CIRCUIT PROTECTION PRODUCTS →]


Download Resources

  • 📄 VOB4-63 Technical Datasheet (PDF)
  • 📄 Installation & Wiring Guide (PDF)
  • 📄 IEC 60898-1 & 60947-2 Compliance Certificate
  • 📄 CAD Drawings (DWG/DXF)
  • 📘 Complete VIOX MCB Product Catalog

[DOWNLOAD ALL RESOURCES]

 

 

Produk Terkait

Minta Penawaran Sekarang

Minta Penawaran Sekarang