ASTP-Y Time Relay

The VIOX ASTP-Y Analog Timer is a reliable and precise time delay relay designed for industrial automation systems and mechanical devices. This device counts down the set time and then switches the relay contacts, maintaining this position until reset. It features a time range of 0-60 seconds, adjustable via an analog dial, and is suitable for various applications requiring accurate timing control.

Ipadala ang iyong mga kinakailangan, mag-quote kami para sa iyo sa loob ng 12 oras

VIOX ASTP-Y Analog Timer

Pangkalahatang-ideya

The VIOX ASTP-Y Analog Timer is a reliable and precise time delay relay designed for industrial automation systems and mechanical devices. This device counts down the set time and then switches the relay contacts, maintaining this position until reset. It features a time range of 0-60 seconds, adjustable via an analog dial, and is suitable for various applications requiring accurate timing control.

Mga Pangunahing Tampok

  • Tumpak na Pagkontrol sa Timing: Adjustable time range mula 0 hanggang 60 segundo na may analog dial.
  • Maaasahang Operasyon: Pinapalitan ang mga contact ng relay pagkatapos ng itinakdang oras at pinapanatili ang posisyon.
  • Mga Dual Relay Output: Dalawang relay output na may maximum na load na 5A bawat isa.
  • Madaling Pag-install: May kasamang PF083A base para sa DIN rail mounting.
  • Mga Visual Indicator: Front panel work indicator para sa madaling pagsubaybay.
  • Matibay na Konstruksyon: Idinisenyo para sa pangmatagalang pagganap na may mataas na mekanikal at elektrikal na buhay.
  • Malawak na Saklaw ng Boltahe: Gumagana sa 230 VAC na may tolerance ng +/-10%.

Mga pagtutukoy

PAG-UURI TIMER TIMER
MODELO ASTP-N ASTP-Y AH2-N AH2-Y
Hitsura
MGA DIMENSYON 61H×49W×70D 88H×58W×68D 61H×49W×70D 88H×58W×68D
MOUNTING
& SOCKET

SURFACE(-N) PF083A(E) PS-08 PF083A(E) PS-08
FLUSH(-Y) US-08 P3G-08 US-08 P3G-08
FULL TIME RANGE SEC:1,3,6,10,12,30,60
MIN:3,6,12,30,60
HR:3,6,12,24
SEC:1,3,6,12,30,60
MIN:3,6,12,30,60
HR:3,6,12,24
RATED VOLTAGE DC(V):12,24 AC(V):12,24,110,220,240, 50/60Hz DC(V):12,24 AC(V):12,24,110,220,240, 50/60Hz
INDICATOR OPERATING Oras ng Operasyon ON-UP Dalawang indicator Lamp ON-UP
CONTACT MODELO ASTP-N1/ ASTP-Y1 ASTP-N2/ ASTP-Y2 ASTP-N/ ASTP-Y AH2-N1/ AH2-Y1 AH2-N2/ AH2-Y2 AH2-N/ AH2-Y
TIME LIMIT 1C 5A 5A 5A 5A
LIMITANG PANAHON 2C 5A 5A
AGAD 1C 5A 5A
BUHAY MEKANIKAL 5×10beses 5×10beses
KURYENTE 10beses 10beses
TUMPAK UULITIN ANG ERROR ±1% max ±1% max
SETTING ERROR ±10% max ±10% max
VOLTAGE ERROR ±1% max ±1% max
TEMP. ERROR ±2% max ±2% max
I-RESET ANG ORAS 0.1 segundo ang max 0.1 segundo ang max
KONSUMO NG KAPANGYARIHAN 2VA 3VA
AMBIENT TEMPERATURE -10 ℃~+55 ℃ -10 ℃~+55 ℃
AMBIENT HUMIDITY 48~85%RH 48~85%RH
TIMBANG 220g 220g
CONNECTION DIAGRAMS & TIME CHART 39A 39B 39C 39D 39E 39F

Mga aplikasyon

Ang VIOX ASTP-Y Analog Timer ay perpekto para sa iba't ibang mga aplikasyon sa industriyal na automation at mekanikal na mga aparato. Ito ay angkop para sa paggamit sa mga control panel, makinarya, at iba pang mga sistema na nangangailangan ng tumpak na kontrol sa tiyempo. Ang matibay na disenyo ng timer at maaasahang pagganap ay ginagawa itong isang mahusay na pagpipilian para sa parehong komersyal at pang-industriya na kapaligiran.

Teknikal na Data

  • Power Supply: 230 VAC +/-10%
  • Output: Relay
  • Max. load: 5A
  • Saklaw ng Oras: 0-60 segundo
  • Mga sukat: 40×50 mm
  • Assembly: DIN Rail, Sa mesa
  • Resolusyon: Analog na Dial
  • Degree ng Proteksyon: IP 40
  • Mekanikal na buhay: 5×106 beses
  • Buhay ng Elektrisidad: 105 beses
  • Katumpakan: Ulitin ang Error: ±1% Max., Setting Error: ±10% Max., Voltage Error: ±1% Max., Temp. Error: ±2% Max.
  • I-reset ang Oras: 0.1 Sec. Max.
  • Naubos na kapangyarihan: 2VA
  • Ambient Temperatura: -10 ℃ hanggang +55 ℃
  • Ambient Humidity: 48% hanggang 85% RH
  • Timbang: 220g

Diagram ng Koneksyon

Ang VIOX ASTP-Y Analog Timer ay nagtatampok ng isang direktang diagram ng koneksyon para sa madaling pag-install. Ang aparato ay magsisimulang bilangin ang nakatakdang oras kapag ang power supply ng boltahe ay inilapat, pagkatapos ay inililipat ang mga contact ng relay at nananatili sa posisyong ito. Gumagana ang Relay A1 ayon sa itinakdang oras sa panel, habang ang Relay A2 ay gumagana ayon sa power supply ng timer.

Mga Mode ng Output

Kapag inilapat ang boltahe ng power supply, magsisimulang bilangin ng device ang itinakdang oras at pagkatapos ay palitan ang mga contact ng relay, na pinapanatili ang posisyong ito. Gumagana ang Relay A1 ayon sa itinakdang oras sa panel, at gumagana ang Relay A2 ayon sa power supply ng timer. Nasa ibaba ang diagram ng operasyon:

 

Mga Kaugnay na Produkto

Humingi ng Quote Ngayon

Humingi ng Quote Ngayon