ASTP-Y Time Relay
The VIOX ASTP-Y Analog Timer is a reliable and precise time delay relay designed for industrial automation systems and mechanical devices. This device counts down the set time and then switches the relay contacts, maintaining this position until reset. It features a time range of 0-60 seconds, adjustable via an analog dial, and is suitable for various applications requiring accurate timing control.
Ipadala ang iyong mga kinakailangan, mag-quote kami para sa iyo sa loob ng 12 oras
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:[email protected]
VIOX ASTP-Y Analog Timer
Pangkalahatang-ideya
The VIOX ASTP-Y Analog Timer is a reliable and precise time delay relay designed for industrial automation systems and mechanical devices. This device counts down the set time and then switches the relay contacts, maintaining this position until reset. It features a time range of 0-60 seconds, adjustable via an analog dial, and is suitable for various applications requiring accurate timing control.
Mga Pangunahing Tampok
- Tumpak na Pagkontrol sa Timing: Adjustable time range mula 0 hanggang 60 segundo na may analog dial.
- Maaasahang Operasyon: Pinapalitan ang mga contact ng relay pagkatapos ng itinakdang oras at pinapanatili ang posisyon.
- Mga Dual Relay Output: Dalawang relay output na may maximum na load na 5A bawat isa.
- Madaling Pag-install: May kasamang PF083A base para sa DIN rail mounting.
- Mga Visual Indicator: Front panel work indicator para sa madaling pagsubaybay.
- Matibay na Konstruksyon: Idinisenyo para sa pangmatagalang pagganap na may mataas na mekanikal at elektrikal na buhay.
- Malawak na Saklaw ng Boltahe: Gumagana sa 230 VAC na may tolerance ng +/-10%.
Mga pagtutukoy
| PAG-UURI | TIMER | TIMER | ||||||
| MODELO | ASTP-N | ASTP-Y | AH2-N | AH2-Y | ||||
| Hitsura | ||||||||
| MGA DIMENSYON | 61H×49W×70D | 88H×58W×68D | 61H×49W×70D | 88H×58W×68D | ||||
| MOUNTING & SOCKET |
SURFACE(-N) | PF083A(E) PS-08 | PF083A(E) PS-08 | |||||
| FLUSH(-Y) | US-08 P3G-08 | US-08 P3G-08 | ||||||
| FULL TIME RANGE | SEC:1,3,6,10,12,30,60 MIN:3,6,12,30,60 HR:3,6,12,24 |
SEC:1,3,6,12,30,60 MIN:3,6,12,30,60 HR:3,6,12,24 |
||||||
| RATED VOLTAGE | DC(V):12,24 AC(V):12,24,110,220,240, 50/60Hz | DC(V):12,24 AC(V):12,24,110,220,240, 50/60Hz | ||||||
| INDICATOR OPERATING | Oras ng Operasyon | ON-UP Dalawang indicator Lamp ON-UP | ||||||
| CONTACT | MODELO | ASTP-N1/ ASTP-Y1 | ASTP-N2/ ASTP-Y2 | ASTP-N/ ASTP-Y | AH2-N1/ AH2-Y1 | AH2-N2/ AH2-Y2 | AH2-N/ AH2-Y | |
| TIME LIMIT 1C | 5A | 5A | 5A | 5A | ||||
| LIMITANG PANAHON 2C | 5A | 5A | ||||||
| AGAD 1C | 5A | 5A | ||||||
| BUHAY | MEKANIKAL | 5×106 beses | 5×106 beses | |||||
| KURYENTE | 105 beses | 105 beses | ||||||
| TUMPAK | UULITIN ANG ERROR | ±1% max | ±1% max | |||||
| SETTING ERROR | ±10% max | ±10% max | ||||||
| VOLTAGE ERROR | ±1% max | ±1% max | ||||||
| TEMP. ERROR | ±2% max | ±2% max | ||||||
| I-RESET ANG ORAS | 0.1 segundo ang max | 0.1 segundo ang max | ||||||
| KONSUMO NG KAPANGYARIHAN | 2VA | 3VA | ||||||
| AMBIENT TEMPERATURE | -10 ℃~+55 ℃ | -10 ℃~+55 ℃ | ||||||
| AMBIENT HUMIDITY | 48~85%RH | 48~85%RH | ||||||
| TIMBANG | 220g | 220g | ||||||
| CONNECTION DIAGRAMS & TIME CHART | 39A | 39B | 39C | 39D | 39E | 39F | ||
Mga aplikasyon
Ang VIOX ASTP-Y Analog Timer ay perpekto para sa iba't ibang mga aplikasyon sa industriyal na automation at mekanikal na mga aparato. Ito ay angkop para sa paggamit sa mga control panel, makinarya, at iba pang mga sistema na nangangailangan ng tumpak na kontrol sa tiyempo. Ang matibay na disenyo ng timer at maaasahang pagganap ay ginagawa itong isang mahusay na pagpipilian para sa parehong komersyal at pang-industriya na kapaligiran.
Teknikal na Data
- Power Supply: 230 VAC +/-10%
- Output: Relay
- Max. load: 5A
- Saklaw ng Oras: 0-60 segundo
- Mga sukat: 40×50 mm
- Assembly: DIN Rail, Sa mesa
- Resolusyon: Analog na Dial
- Degree ng Proteksyon: IP 40
- Mekanikal na buhay: 5×106 beses
- Buhay ng Elektrisidad: 105 beses
- Katumpakan: Ulitin ang Error: ±1% Max., Setting Error: ±10% Max., Voltage Error: ±1% Max., Temp. Error: ±2% Max.
- I-reset ang Oras: 0.1 Sec. Max.
- Naubos na kapangyarihan: 2VA
- Ambient Temperatura: -10 ℃ hanggang +55 ℃
- Ambient Humidity: 48% hanggang 85% RH
- Timbang: 220g
Diagram ng Koneksyon
Ang VIOX ASTP-Y Analog Timer ay nagtatampok ng isang direktang diagram ng koneksyon para sa madaling pag-install. Ang aparato ay magsisimulang bilangin ang nakatakdang oras kapag ang power supply ng boltahe ay inilapat, pagkatapos ay inililipat ang mga contact ng relay at nananatili sa posisyong ito. Gumagana ang Relay A1 ayon sa itinakdang oras sa panel, habang ang Relay A2 ay gumagana ayon sa power supply ng timer.
Mga Mode ng Output
Kapag inilapat ang boltahe ng power supply, magsisimulang bilangin ng device ang itinakdang oras at pagkatapos ay palitan ang mga contact ng relay, na pinapanatili ang posisyong ito. Gumagana ang Relay A1 ayon sa itinakdang oras sa panel, at gumagana ang Relay A2 ayon sa power supply ng timer. Nasa ibaba ang diagram ng operasyon:






