VIOX VSP1-D20/1 (S) SPD Kutub Tunggal yang Dapat Dicolokkan

VIOX VSP1-D20/1(S) Pluggable Single-Pole SPD offers robust surge protection for sub-distribution boards. This Class II/III device safeguards L-PE and N-PE modes with 10kA nominal discharge current. Featuring high-energy MOV elements, it operates from 60V to 400V AC. The pluggable design ensures easy installation on 35mm DIN rails. IEC 61643-11:2011 and EN 61643-11:2012 compliant, it provides voltage protection levels from 0.2kV to 1.8kV. With IP20 protection, thermal safeguards, and optional remote contacts, this versatile SPD suits various electrical installations, combining reliability and performance in a compact, user-friendly package.

Kirimkan kebutuhan Anda, kami akan mengutip untuk Anda dalam waktu 12 jam

VIOX VSP1-D20/1 (S) SPD Kutub Tunggal yang Dapat Dicolokkan

Ikhtisar

The VIOX VSP1-D20/1(S) is a high-performance Pluggable Single-Pole Surge Protective Device (SPD) designed for use in sub-distribution boards. This versatile device offers robust protection for both L-PE and N-PE modes, making it an ideal solution for various electrical installations.

Fitur Utama

  • Perangkat Kelas II, Kelas III, Tipe 2, Tipe 3
  • Lokasi Penggunaan: Papan Sub-Distribusi
  • Mode Perlindungan: L-PE, N-PE
  • Peringkat Lonjakan: Dalam = 10 kA (8/20 μs)
  • Kategori IEC/EN/UL: Kelas II + III / Tipe 2 + 3
  • Elemen Pelindung: MOV Energi Tinggi
  • Perumahan: Desain yang Dapat Dicolokkan
  • Kepatuhan: IEC 61643-11: 2011, EN 61643-11: 2012

Spesifikasi Teknis

IEC Electrical 75 150 275 320 385 440
Tegangan AC Nominal (50/60Hz) 60 V 120 V 230 V 230 V 230 V 400 V
Tegangan Operasi Kontinu Maksimum (AC) 75 V 150 V 275V 320 V 385 V 440 V
Arus Pelepasan Nominal (8/20 μs) 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA
Arus Pelepasan Maksimum (8/20 μs) 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA
Tingkat Perlindungan Tegangan 0.2 kV 0,6 kV 1,3 kV 1,5 kV 1,5 kV 1,8 kV

Spesifikasi Mekanik & Lingkungan

  • Operating Temperature Range: -40°F to +158°F (-40°C to +70°C)
  • Kelembaban Pengoperasian yang Diizinkan: 5%... 95%
  • Tekanan atmosfer dan ketinggian: 80k Pa ... 106k Pa / -500 m....2000 m
  • Torsi Sekrup Terminal: 39,9 lbf.in [4,5 Nm]
  • Penampang Konduktor (maks): 2 AWG (Padat, Terdampar) / 4 AWG (Fleksibel)
  • Pemasangan: Rel DIN 35 mm, EN 60715
  • Tingkat Perlindungan: IP 20 (built-in)
  • Bahan Perumahan: Termoplastik: Derajat Pemadaman UL 94 V-0
  • Perlindungan Termal: Ya
  • Status Operasi / Indikasi Kesalahan: Hijau ok / Cacat merah

Fitur Tambahan

  • Kontak Jarak Jauh (RC): Opsional
  • RC Switching Capacity: AC: 250V / 0.5 A; DC: 250V / 0.1 A; 125V / 0.2 A; 75V / 0.5 A

Penampang Konduktor RC (maks): 16 AWG (Padat) / 1,5 mm² (Padat)

Konfigurasi Internal

 Internal Configuration of VIOX VSP1-D20_1(S) Pluggable Single-Pole SPD

Dimensi

Dimension of VIOX VSP1-D20_1(S) Pluggable Single-Pole SPD

Diagram Koneksi

 Connection Diagram of VIOX VSP1-D20_1(S) Pluggable Single-Pole SPD