VIOX VSP1-C40PV/3 (S) 1000V (D4) SPD Multi-Kutub yang Dapat Dicolokkan

VIOX VSP1-C40PV/3(S) 1000V(D4) Pluggable Multi-Pole SPD offers robust surge protection for high-voltage photovoltaic systems and DC applications. This Class I+II/Type 1+2 device safeguards (DC+) – PE and (DC-) – PE modes with 20kA nominal and 40kA maximum discharge current. Featuring high-energy MOV elements, it operates at 1000V DC with < 25ns response time. The pluggable design ensures easy installation on 35mm DIN rails. Compliant with IEC 61643-31:2018 and EN 50539-11:2013+A1:2014, it provides a voltage protection level of 3.6kV. With IP20 protection, thermal safeguards, and optional remote contacts, this versatile multi-pole SPD combines reliability and performance for enhanced power system protection in demanding high-voltage DC and photovoltaic applications.

Kirimkan kebutuhan Anda, kami akan mengutip untuk Anda dalam waktu 12 jam

VIOX VSP1-C40PV/3 (S) 1000V (D4) SPD Multi-Kutub yang Dapat Dicolokkan

Ikhtisar

The VIOX VSP1-C40PV/3(S) 1000V(D4) is a high-performance Pluggable Multi-Pole Surge Protective Device (SPD) designed for use in sub-distribution boards. This versatile device offers robust protection for (DC+) – PE and (DC-) – PE modes, making it an ideal solution for high-voltage photovoltaic systems and other DC applications requiring multi-pole protection.

Fitur Utama

  • Class I, Class II, Type 1, Type 2 device
  • Lokasi Penggunaan: Papan Sub-Distribusi
  • Mode of Protection: (DC+) – PE, (DC-) – PE
  • Peringkat Lonjakan: Dalam = 20 kA (8/20 μs)
  • IEC/EN/UL Category: Class I+II / Type 1+2
  • Elemen Pelindung: MOV Energi Tinggi
  • Perumahan: Desain yang Dapat Dicolokkan
  • Compliance: IEC 61643-31:2018, EN 50539-11:2013+A1:2014

Spesifikasi Teknis

IEC Electrical 1000
Nominal AC Voltage 1000 V
Maximum Continuous Operating Voltage (DC) 1000 V
Arus Pelepasan Nominal (8/20 μs) 20 kA
Arus Pelepasan Maksimum (8/20 μs) 40 kA
Impulse Discharge Current (10/350 μs) 6.25 kA
Tingkat Perlindungan Tegangan 3.6 kV
Waktu Tanggapan <25 ns
Sekering Cadangan (maks) 125 A gL / gG
Peringkat Arus Hubung Singkat (AC) 25 kA / 50 kA

Spesifikasi Mekanik & Lingkungan

  • Kisaran Suhu Pengoperasian: -40°F hingga +158°F (-40°C hingga +70°C)
  • Kelembaban Pengoperasian yang Diizinkan: 5%... 95%
  • Tekanan atmosfer dan ketinggian: 80k Pa ... 106k Pa / -500 m....2000 m
  • Torsi Sekrup Terminal: 39,9 lbf.in [4,5 Nm]
  • Penampang Konduktor (maks): 2 AWG (Padat, Terdampar) / 4 AWG (Fleksibel)
  • 35 mm² (Padat, Terdampar) / 25 mm² (Fleksibel)
  • Pemasangan: Rel DIN 35 mm, EN 60715
  • Tingkat Perlindungan: IP 20 (built-in)
  • Bahan Perumahan: Termoplastik: Derajat Pemadaman UL 94 V-0
  • Perlindungan Termal: Ya
  • Status Operasi / Indikasi Kesalahan: Hijau ok / Cacat merah

Fitur Tambahan

  • Kontak Jarak Jauh (RC): Opsional
  • Kapasitas Pengalihan RC: AC: 250V / 0,5 A; DC: 250V / 0,1 A; 125V / 0,2 A; 75V / 0,5 A
  • Penampang Konduktor RC (maks): 16 AWG (Padat) / 1,5 mm² (Padat)

Konfigurasi Internal

Dimensi

Diagram Koneksi

Produk Terkait

Minta Penawaran Sekarang

Minta Penawaran Sekarang