VOB4-63 MCB – Miniature Circuit Breaker
- Dual Breaking Capacity: 6000A or 10000A – superior fault protection for industrial systems
- Enhanced Insulation: AC 500V rated insulation voltage (higher than standard 415V)
- Dual Standard Compliance: IEC 60898-1 & IEC 60947-2 certified for both residential and industrial applications
- Complete Rating Range: 1A to 63A in full increments (1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 13A, 16A, 20A, 25A, 32A, 40A, 50A, 63A)
- All Trip Curves Available: Type B, C, D curves for any application requirement
- Промислова довговічність: 10,000 mechanical operations, 4,000 electrical cycles
- Професійний монтаж: DIN rail mounting, 1-25mm² terminal capacity
- Proven Quality: Manufactured by ISO 9001:2015 certified VIOX Electric
Надішліть свої вимоги, і ми надамо вам пропозицію протягом 12 годин
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:[email protected]
VOB4-63 High-Performance Miniature Circuit Breaker
Industrial-Grade MCB with 6kA/10kA Breaking Capacity – VIOX VOB4-63 series miniature circuit breakers deliver superior protection for demanding commercial and industrial installations. Dual-standard compliant (IEC 60898-1 & IEC 60947-2), thermal-magnetic trip technology, 500V insulation rating, complete range from 1A to 63A.
Why Choose VOB4-63 High-Performance MCB?
- Dual Breaking Capacity: 6000A or 10000A – superior fault protection for industrial systems
- Enhanced Insulation: AC 500V rated insulation voltage (higher than standard 415V)
- Dual Standard Compliance: IEC 60898-1 & IEC 60947-2 certified for both residential and industrial applications
- Complete Rating Range: 1A to 63A in full increments (1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 13A, 16A, 20A, 25A, 32A, 40A, 50A, 63A)
- All Trip Curves Available: Type B, C, D curves for any application requirement
- Промислова довговічність: 10,000 mechanical operations, 4,000 electrical cycles
- Професійний монтаж: DIN rail mounting, 1-25mm² terminal capacity
- Proven Quality: Manufactured by ISO 9001:2015 certified VIOX Electric
Complete Technical Specifications
| Параметр | Специфікація |
|---|---|
| Product Series | VOB4-63 |
| Розривна здатність (Icn) | 6000A or 10000A |
| Кількість поляків | 1P, 2P, 3P, 4P |
| Номінальний струм (В) | 1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 13A, 16A, 20A, 25A, 32A, 40A, 50A, 63A |
| Номінальна робоча напруга | 1P: 240V/415V~ 2P, 3P, 4P: 415V~ |
| Trip Unit Technology | Термомагнітний |
| Curve Code (Trip Characteristics) | B, C, D (all curves available) |
| Номінальна напруга ізоляції (Ui) | AC 500V~ (enhanced) |
| Номінальна імпульсна витримувана напруга (Uimp) | 4000V |
| Механічна міцність | 10 000 циклів |
| Електрична довговічність | 4,000 cycles |
| Момент затягування | M5 2.5N·m ⚠ |
| IP Degree of Protection | IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529 |
| Ambient Air Temperature for Operation | -5°C to +40°C |
| Відповідність стандартам | IEC 60898-1 & IEC 60947-2 |
| EU RoHS Directive | Compliant EU RoHS Declaration |
| Ступінь забруднення | 2 conforming to IEC/EN 60898-1 |
| Пропускна спроможність терміналу | Upper/Lower Wiring: 1-25mm² (flexible/rigid conductor) |
| Монтаж | 35mm DIN rail (IEC/EN 60715) |
Understanding Breaking Capacity: 6kA vs 10kA
The VOB4-63 series offers two breaking capacity options to match your installation requirements:
6kA Breaking Capacity (6000A)
- Найкраще для: Residential buildings, small commercial offices, light industrial facilities
- Typical installations: Lighting circuits, small motor loads, general power distribution
- Fault current handling: Up to 6,000 amperes short-circuit protection
10kA Breaking Capacity (10000A) – Recommended for Industrial
- Найкраще для: Industrial plants, large commercial buildings, high-power equipment installations
- Typical installations: Motor control centers, industrial automation, heavy machinery protection
- Fault current handling: Up to 10,000 amperes short-circuit protection
- Additional safety margin: 67% higher capacity than 6kA for demanding applications
How to Choose: Calculate your installation’s prospective short-circuit current (PSC). For most industrial applications with transformers above 200kVA, 10kA breaking capacity is recommended.
Trip Curve Selection Guide
Select the correct trip curve based on your load characteristics:
Type B Curve MCB (3-5 × In)
Best for resistive loads with minimal inrush current:
- Residential and commercial lighting circuits
- Heating elements and resistive heaters
- Domestic appliances
- Long cable runs where trip sensitivity is needed
Type C Curve MCB (5-10 × In) – Most Common
Best for general-purpose commercial and industrial applications:
- Motor-driven equipment (pumps, fans, compressors)
- Fluorescent and LED lighting with electronic ballasts
- Transformers and inductive loads
- Системи опалення, вентиляції та кондиціонування
- General power distribution panels
Type D Curve MCB (10-20 × In)
Best for high inrush current loads:
- Large industrial motors and motor starters
- Welding equipment and X-ray machines
- Large transformers with high magnetizing inrush
- Capacitive loads
- Industrial machinery with high starting currents
Applications by Industry
Промислове виробництво
- Motor control centers (MCCs) for production equipment
- CNC machines and industrial automation systems
- Conveyor systems and material handling equipment
- Industrial robots and automated assembly lines
- Power distribution in factory electrical panels
Комерційні будівлі
- Office building main and sub-distribution boards
- Shopping mall electrical systems
- Hotel and hospitality power distribution
- Data center electrical protection
- Commercial HVAC and mechanical systems
Infrastructure & Construction
- Public building electrical installations
- Educational facilities (schools, universities)
- Healthcare facilities (hospitals, clinics)
- Transportation hubs (airports, train stations)
- Government and municipal buildings
Energy & Utilities
- Solar PV system protection circuits
- Wind turbine electrical systems
- Power generation auxiliary equipment
- Electrical substations and switchgear
- Energy storage system protection
OEM & Panel Builders
- Electrical panel manufacturers and switchgear assemblers
- Control system integrators
- Industrial equipment manufacturers
- Automation system providers
- Custom electrical solution designers
Dimensions & Installation Data
Modular Width (Standard 18mm Module):
- 1P: 1 module (17.8mm)
- 2P: 2 modules (35.6mm)
- 3P: 3 modules (53.4mm)
- 4P: 4 modules (71.2mm)
Фізичні розміри:
- Height: 83mm
- Depth: 74mm (1P), 63.5mm (multi-pole)
- DIN rail depth: 35mm
Інсталяція:
- Mounting: Standard 35mm DIN rail per IEC/EN 60715
- Terminal type: Screw terminals (torque-controlled)
- Wire capacity: 1-25mm² (both stranded and solid conductors)
- Connection: Top and bottom terminals for daisy-chain wiring

Certifications & Quality Standards
Відповідність міжнародним стандартам
✓ IEC 60898-1: Household and similar installations (residential, light commercial)
✓ ІЕК 60947-2: Industrial low-voltage switchgear and controlgear
✓ EN 60898-1: European standard for MCB performance
✓ Pollution Degree 2: Suitable for standard industrial environments
Manufacturing Quality
✓ ISO 9001:2015 Certified: Quality management system certified
✓ EU RoHS Compliant: Lead-free, environmentally responsible manufacturing
✓ Factory Testing: 100% electrical testing before shipment
✓ Traceability: Full batch tracking and quality documentation
Third-Party Verification
✓ Independent laboratory testing for breaking capacity verification
✓ Type testing per IEC standards
✓ Continuous production monitoring
VOB4-63 vs VOB3-63: Which MCB Should You Choose?
| Особливість | VOB3-63 | VOB4-63 |
|---|---|---|
| Пропускна здатність | 4.5kA / 6kA | 6kA / 10kA ✓ |
| Insulation Voltage | 415V~ | 500V~ ✓ |
| Стандарти | IEC 60898-1 | IEC 60898-1 & 60947-2 ✓ |
| Recommended Use | Residential, Light Commercial | Industrial, Heavy Commercial |
| Ціна | Економіка | Преміум |
Choose VOB4-63 when:
- Working in industrial environments with higher fault currents
- Protecting high-value equipment requiring maximum safety margin
- Compliance with IEC 60947-2 is required
- Long-term reliability in demanding conditions is critical
Why VIOX Electric for Your MCB Supply?
Direct Manufacturer Advantages
- Factory-direct pricing without middleman markup
- Consistent quality control throughout production
- Flexible MOQ for both small orders and bulk projects
- Custom labeling and OEM partnership available
Технічна підтримка
- Pre-sales engineering consultation
- Application-specific recommendations
- Технічна документація кількома мовами
- After-sales technical support
Global Supply Capability
- ISO 9001:2015 certified manufacturing facility
- Capacity for large-volume orders
- Reliable delivery schedules
- International shipping experience
Асортимент продукції
- Complete MCB ratings from 1A to 63A
- All pole configurations (1P, 2P, 3P, 4P)
- All trip curves (B, C, D)
- Both breaking capacities (6kA, 10kA)
How to Order VOB4-63 MCB
Model Numbering System: VOB4-63 [Breaking Capacity] [Poles] [Curve] [Rating]
Examples:
- VOB4-63 10kA 3P C 32A – 10kA, 3-Pole, Type C curve, 32A rated current
- VOB4-63 6kA 2P C 16A – 6kA, 2-Pole, Type C curve, 16A rated current
- VOB4-63 10kA 4P D 63A – 10kA, 4-Pole, Type D curve, 63A rated current
Ordering Information Checklist:
- Breaking capacity required (6kA or 10kA)
- Number of poles (1P, 2P, 3P, 4P)
- Trip curve type (B, C, or D)
- Rated current (1A to 63A)
- Необхідна кількість
- Delivery timeline
Get Your Quote Today
Contact VIOX Electric – MCB Manufacturer
For Distributors & Volume Orders:
- Competitive volume pricing tiers
- Distributor partnership programs
- Co-branding and private labeling options
- Technical training and support
For Panel Builders & OEM:
- Engineering sample requests
- Custom specifications available
- CAD drawings and technical documentation
- Integration support
For Electrical Contractors:
- Project-specific quotations
- Mixed order flexibility
- Fast delivery for urgent projects
- Технічна підтримка додатків
Часті запитання (FAQ)
Q: What’s the difference between 6kA and 10kA breaking capacity?
A: The breaking capacity indicates the maximum short-circuit current the MCB can safely interrupt. 10kA provides 67% more protection than 6kA, making it essential for industrial installations with higher fault current levels.
Q: Can VOB4-63 replace my existing MCB?
A: Yes, VOB4-63 is DIN-rail compatible and follows standard modular sizing. Ensure the breaking capacity, voltage rating, and pole configuration match your application requirements.
Q: What’s the lead time for bulk orders?
A: Standard lead time is 2-4 weeks depending on order quantity and specifications. Contact our sales team for urgent orders.
Q: Do you provide technical documentation?
A: Yes, complete technical datasheets, CAD drawings, installation manuals, and certificates are provided with every order.
Q: What’s your MOQ (Minimum Order Quantity)?
A: We accommodate both small sample orders and large-volume projects. Contact us for specific MOQ based on your requirements.
Related VIOX Circuit Protection Products
- MCCB Series (Molded Case Circuit Breakers): For higher ratings up to 1600A and breaking capacities up to 100kA
- RCCB/RCBO: Add earth leakage protection with residual current devices
- ACB Series (Air Circuit Breakers): Main distribution circuit breakers for large facilities
- Load Break Switches: Manual isolation and switching up to 125A
- SPD (Surge Protection Devices): Lightning and surge protection
[VIEW ALL CIRCUIT PROTECTION PRODUCTS →]
Download Resources
- 📄 VOB4-63 Technical Datasheet (PDF)
- 📄 Installation & Wiring Guide (PDF)
- 📄 IEC 60898-1 & 60947-2 Compliance Certificate
- 📄 CAD Drawings (DWG/DXF)
- 📘 Complete VIOX MCB Product Catalog