VIOX VSP1-D20/1(S)+1 Zásuvný jednopólový SPD
VIOX VSP1-D20/1(S)+1 Pluggable Single-Pole SPD offers comprehensive surge protection for sub-distribution boards. This Class II+III/Type 2+3 device safeguards L-N and N-PE modes with 10kA nominal and 20kA maximum discharge current. Featuring high-energy MOV and GDT elements, it operates from 60V to 400V AC with <25ns response time for L-N and <100ns for N-PE. IEC 61643-11:2011 and EN 61643-11:2012 compliant, it provides voltage protection levels from 0.2kV to 1.8kV. With IP20 protection, thermal safeguards, and optional remote contacts, this versatile SPD suits various electrical installations, combining reliability and performance for enhanced power system protection in diverse applications.
Pošlite nám svoje požiadavky, do 12 hodín vám vypracujeme cenovú ponuku
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:sales@viox.com
VIOX VSP1-D20/1(S)+1 Zásuvný jednopólový SPD
Prehľad
The VIOX VSP1-D20/1(S)+1 is a high-performance Pluggable Single-Pole Surge Protective Device (SPD) designed for use in sub-distribution boards. This versatile device offers robust protection for L-N and N-PE modes, making it an ideal solution for various electrical installations.
Kľúčové vlastnosti
- Zariadenie triedy II, triedy III, typu 2, typu 3
- Miesto použitia: Subdistribučné dosky
- Mode of Protection: L-N, N-PE
- Hodnotenie prepätia: In = 10 kA (8/20 μs)
- IEC/EN/UL Category: Class II+III / Type 2+3
- Protective Elements: High Energy MOV and GDT
- Bývanie: Zásuvný dizajn
- Dodržiavanie predpisov: IEC 61643-11:2011, EN 61643-11:2012
Technické špecifikácie
IEC Electrical | 75 | 150 | 275 | 320 | 385 | 440 |
---|---|---|---|---|---|---|
Menovité striedavé napätie (50/60 Hz) | 60 V | 120 V | 230 V | 230 V | 230 V | 400 V |
Maximum Continuous Operating Voltage (AC) (L-N) | 75 V | 150 V | 275V | 320 V | 385 V | 440 V |
Maximum Continuous Operating Voltage (AC) (N-PE) | 255V | |||||
Nominal Discharge Current (8/20 μs) (L-N) / (N-PE) | 10kV / 10kA | |||||
Maximum Discharge Current (8/20 μs) (L-N) / (N-PE) | 20 kA / 20 kA | |||||
Voltage Protection Level (L-N) / (N-PE) | 0.2kV/1.5kV | 0.6kV/1.5kV | 1.3kV/1.5kV | 1.5kV/1.5kV | 1.5kV/1.5kV | 1.8kV/1.5kV |
Follow Current Interrupt Rating (N-PE) | 100Arms | |||||
Response Time (L-N) / (N-PE) | < 25 ns / < 100 ns | |||||
Záložná poistka (max.) | 125 A gL / gG | |||||
Short-Circuit Current Rating (AC) (L-N) | 10 kA | |||||
TOV Withstand 5s (L-N) | 90V | 180V | 335V | 335V | 335V | 580V |
TOV 120min (L-N) | 115V | 230V | 440V | 440V | 440V | 765V |
režim | Odolnosť | Odolnosť | Bezpečné zlyhanie | Bezpečné zlyhanie | Bezpečné zlyhanie | Bezpečné zlyhanie |
TOV Withstand 200ms (N-PE) | 1200V |
Mechanické a environmentálne špecifikácie
- Rozsah prevádzkových teplôt: -40°F až +158°F [-40°C až +70°C]
- Prípustná prevádzková vlhkosť: 5%...95%
- Atmosférický tlak a nadmorská výška: 80k Pa ... 106k Pa / -500 m....2000 m
- Krútiaci moment svorkových skrutiek: 39,9 lbf.in [4,5 Nm]
- Prierez vodiča (max.): 2 AWG (plný, viazaný) / 4 AWG (ohybný)
- 35 mm² (plný, viazaný) / 25 mm² (ohybný)
- Montáž: 35 mm DIN lišta, EN 60715
- Stupeň ochrany: IP 20 (zabudované)
- Materiál puzdra: Stupeň zhasnutia UL 94 V-0
- Tepelná ochrana: Áno
- Prevádzkový stav / indikácia poruchy: Zelená farba v poriadku / červená farba porucha
Ďalšie funkcie
- Vzdialené kontakty (RC): Voliteľné
- RC Switching Capacity: AC: 250V / 0.5 A; DC: 250V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A
- Prierez vodiča RC (max.): 16 AWG (plný) / 1,5 mm² (plný)