CTB3315 Bloc terminal ceramic
VIOX CTB3315 Ceramic Terminal Block offers a 3-in-3-out, 15A design for medium-current multi-circuit needs. With 750°C heat resistance, it’s ideal for industrial control systems and HVAC. Trust VIOX for durable, safe connections in challenging high-temperature industrial settings.
Trimiteți cerințele dvs., vom cita pentru dvs. în termen de 12 ore
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:sales@viox.com
The CTB3315 Ceramic Terminal Block represents a significant advancement in medium-current multi-circuit connection technology, offering an efficient and reliable 3-in-3-out configuration rated at 15A. This professional-grade terminal block combines enhanced current-carrying capacity with superior thermal stability and excellent electrical insulation properties, making it the ideal choice for engineers and electricians working on complex projects requiring multiple medium-current connections with unwavering reliability and safety.
Advanced Multi-Circuit Design with Enhanced Current Capacity
The CTB3315 features an innovative 3-in-3-out configuration specifically engineered to handle increased current loads up to 15A while facilitating complex circuit arrangements. Meticulously crafted from high-frequency ceramic material, this terminal block delivers superior insulation properties that significantly outperform conventional plastic alternatives in medium-current, high-temperature environments. The ceramic housing ensures complete resistance to aging, cracking, and deformation even under extreme temperature conditions up to 750°C, guaranteeing long-term stability and safety for your critical electrical connections.
Each terminal block incorporates six precision-engineered connection points with substantial copper core conductors designed for optimal electrical performance and M4-compatible screw terminals manufactured from durable iron-plated zinc material. This construction provides exceptionally secure wire clamping that maintains consistent contact pressure even when subjected to vibration, thermal cycling, and sustained current loads – ensuring reliable performance across all three circuits in demanding applications.
Caracteristici principale și avantaje tehnice
- Enhanced Current Capacity: 15A rating provides additional headroom for medium-current applications requiring multiple connection points
- Configurație circuit extinsă: Designul cu trei intrări și trei ieșiri permite conexiuni paralele multiple sau trei circuite separate într-un singur bloc terminal compact
- Integrated Mounting System: Built-in 12mm spaced mounting holes for secure and standardized installation in control panels and junction boxes
- Capacitate crescută a sârmei: Accommodates wire gauges from 0.5mm² to 4mm², providing flexibility for various medium-current installation requirements
- Intrare sârmă mai mare: 4mm diameter wire entry holes facilitate easier installation of medium gauge wires
- M4 Compatibilitate șurub: Designed to work with standard M4 screws for secure connections and easy maintenance
- Rezistență superioară la temperatură: Withstands continuous operation at high temperatures up to 750°C, ideal for applications where plastic terminals would fail
- Izolație electrică excelentă: Materialul ceramic oferă o rezistență dielectrică excepțională și previne scurgerile de curent între circuitele adiacente
- Retardant la flăcări: Materialul natural rezistent la foc elimină riscul de aprindere sau propagare a flăcării în instalațiile sensibile
- Rezistență chimică: Impervious to oils, solvents, and most acids, ensuring durability in harsh industrial environments
Specificații tehnice
SPECIFICAȚII | MODEL | LUNGIME | LUNGIME | ÎNALȚIME | GAMA DE CABLURI |
---|---|---|---|---|---|
1 intrare 1 ieșire 10A | CTB1110 | 19mm | 10 mm | 15mm | 0,5-2,5 mm2 |
1 intrare 1 ieșire 30A | CTB1130 | 18mm | 14mm | 18mm | 0.5-6mm2 |
2 In 2 Out 10A | CTB2210 | 20.7mm | 18.9mm | 13.9mm | 0,5-2,5 mm2 |
2 In 2 Out 15A | CTB2215 | 28.4mm | 20.4mm | 16.3mm | 0.5-4mm2 |
2 In 2 Out 30A | CTB2230 | 31mm | 27mm | 18.9mm | 1.5-6mm2 |
2 In 2 Out 60A | CTB2260 | 38.7mm | 31mm | 22.7mm | 2.5-16mm2 |
2 In 2 Out 100A | CTB22100 | 41.1mm | 30.2mm | 25.85mm | 6-25mm2 |
3 In 3 Out 10A | CTB3310 | 31mm | 20mm | 14.3mm | 0,5-2,5 mm2 |
3 intrări 3 ieșiri 15A | CTB3315 | 35.5mm | 20.3mm | 20.2mm | 0.5-4mm2 |
3 In 3 Out 30A | CTB3330 | 46.2mm | 26.4mm | 19.2mm | 1.5-6mm2 |
4 In 4 Out 30A | CTB4430 | 57mm | 25mm | 18.8mm | 1.5-6mm2 |
5 In 5 Out 15A | CTB5515 | 50mm | 22mm | 13mm | 0,5-2,5 mm2 |
6 In 6 Out 15A | CTB6615 | 56.6mm | 21mm | 13mm | 0,5-2,5 mm2 |
8 In 8 Out 15A | CTB8815 | 68mm | 21mm | 13mm | 0,5-2,5 mm2 |
10 In 10 Out 15A | CTB101015 | 88mm | 18mm | 15mm | 0,5-3,5 mm2 |
CTB3315 Detailed Specifications:
- Rating curent: 15A per circuit
- Configurație: Trei intrări, trei ieșiri
- Dimensiuni: 41mm (L) × 23.3mm (W) × 18.9mm (H)
- Gama de sârme: 0.5-4mm²
- Diametrul găurii de intrare a sârmei: 4mm
- Material carcasă: Ceramică de înaltă frecvență
- Material conductor: Miez de cupru
- Material șurub: Zinc placat cu fier
- Compatibilitate șurub: Fir M4
- Distanța dintre găurile de montare: 12mm center-to-center
- Tipuri de cabluri compatibile: Potrivit atât pentru firele moi, cât și pentru cele tari
- Temperatura maximă de funcționare: 750°C
- Rezistența dielectrică: 2.8kV
- Rezistența la izolare: >1000MΩ la 500VDC
- Rezistența la contact: <0,5mΩ
Aplicații versatile
The CTB3315 Ceramic Terminal Block is specifically designed for medium-current applications where multiple circuit connections, reliability, and heat resistance are essential:
- Sisteme de control industrial: Multi-circuit control panels and distribution boxes requiring medium-current capacity
- Three-Phase Equipment: Ideal for three-phase connections in smaller industrial equipment and control systems
- Commercial HVAC: Multiple fan motors, heating elements, and control circuits in commercial heating and cooling systems
- Lighting Infrastructure: Commercial and industrial lighting systems requiring multiple circuit distribution
- Panouri de distribuție a energiei: Medium-current distribution panels with multiple circuit requirements
- Machinery and Equipment: Multiple circuit connections in industrial machinery operating in elevated temperature environments
- Solar and Alternative Energy: Junction boxes and connection points in medium-scale renewable energy installations
- Prelucrarea semnalelor: Industrial instrumentation requiring isolated medium-current circuits with high thermal stability
Ghiduri de instalare profesională
For optimal performance, safety, and compliance with electrical codes, follow these professional installation guidelines:
- Asigurați-vă că suprafața de montare este curată, plană și rezistentă la căldură
- Utilize the integrated 12mm mounting holes for secure and standardized attachment
- Strip wires to the appropriate length (typically 7-9mm)
- For stranded conductors, pre-twist or use ferrules for optimal connection
- Slăbiți complet șuruburile terminalelor înainte de a introduce firele
- Introduceți firul complet în orificiul terminalului
- Tighten M4 screws to a torque of 1.0-1.5 N·m
- Verificați conexiunea sigură prin efectuarea unui test de tracțiune ușoară pe fiecare conductor
- Atunci când se utilizează mai multe circuite, se asigură o separare corespunzătoare între diferitele potențiale electrice
- Etichetați clar fiecare circuit pentru întreținere și depanare ulterioară
The CTB3315 Advantage: Multi-Circuit Excellence with Enhanced Capacity
When selecting terminal blocks for medium-current multi-circuit applications, the CTB3315 Ceramic Terminal Block offers the perfect balance between connection flexibility and current capacity. Its innovative 3-in-3-out configuration with 15A rating provides exceptional versatility for creating complex medium-current circuit arrangements while maintaining the exceptional heat resistance and electrical insulation properties that make ceramic terminal blocks the professional’s choice for critical installations.