VIOX VSP1-D20/1(S)+1 Pluggbar enpolet SPD

VIOX VSP1-D20/1(S)+1 Pluggable Single-Pole SPD offers comprehensive surge protection for sub-distribution boards. This Class II+III/Type 2+3 device safeguards L-N and N-PE modes with 10kA nominal and 20kA maximum discharge current. Featuring high-energy MOV and GDT elements, it operates from 60V to 400V AC with <25ns response time for L-N and <100ns for N-PE. IEC 61643-11:2011 and EN 61643-11:2012 compliant, it provides voltage protection levels from 0.2kV to 1.8kV. With IP20 protection, thermal safeguards, and optional remote contacts, this versatile SPD suits various electrical installations, combining reliability and performance for enhanced power system protection in diverse applications.

Send oss dine krav, så gir vi deg et tilbud innen 12 timer

VIOX VSP1-D20/1(S)+1 Pluggbar enpolet SPD

Oversikt

The VIOX VSP1-D20/1(S)+1 is a high-performance Pluggable Single-Pole Surge Protective Device (SPD) designed for use in sub-distribution boards. This versatile device offers robust protection for L-N and N-PE modes, making it an ideal solution for various electrical installations.

Viktige funksjoner

  • Class II, Class III, Type 2, Type 3 device
  • Bruksområde: Underdistribusjonstavler
  • Mode of Protection: L-N, N-PE
  • Surge Ratings: In = 10 kA (8/20 μs)
  • IEC/EN/UL Category: Class II+III / Type 2+3
  • Protective Elements: High Energy MOV and GDT
  • Hus: Pluggbar design
  • Samsvar: IEC 61643-11:2011, EN 61643-11:2012

Tekniske spesifikasjoner

IEC Elektrisk 75 150 275 320 385 440
Nominell vekselstrømspenning (50/60 Hz) 60 V 120 V 230 V 230 V 230 V 400 V
Maximum Continuous Operating Voltage (AC) (L-N) 75 V 150 V 275V 320 V 385 V 440 V
Maximum Continuous Operating Voltage (AC) (N-PE) 255V
Nominal Discharge Current (8/20 μs) (L-N) / (N-PE) 10kV / 10kA
Maximum Discharge Current (8/20 μs) (L-N) / (N-PE) 20 kA / 20 kA
Voltage Protection Level (L-N) / (N-PE) 0.2kV/1.5kV 0.6kV/1.5kV 1.3kV/1.5kV 1.5kV/1.5kV 1.5kV/1.5kV 1.8kV/1.5kV
Follow Current Interrupt Rating (N-PE) 100Arms
Response Time (L-N) / (N-PE) < 25 ns / < 100 ns
Reservesikring (maks.) 125 A gL / gG
Short-Circuit Current Rating (AC) (L-N) 10 kA
TOV Withstand 5s (L-N) 90V 180V 335V 335V 335V 580V
TOV 120min (L-N) 115V 230V 440V 440V 440V 765V
modus Tåler Tåler Sikker feil Sikker feil Sikker feil Sikker feil
TOV Withstand 200ms (N-PE) 1200V

Mekaniske og miljømessige spesifikasjoner

  • Driftstemperaturområde: -40 °F til +158 °F [-40 °C til +70 °C].
  • Tillatt luftfuktighet ved drift: 5%...95%
  • Atmosfærisk trykk og høyde: 80k Pa ... 106k Pa / -500 m....2000 m
  • Dreiemoment for terminalskruer: 39,9 lbf.in [4,5 Nm]
  • Ledertverrsnitt (maks.): 2 AWG (massiv, fåtrådet) / 4 AWG (fleksibel)
  • 35 mm² (massiv, flertrådet) / 25 mm² (fleksibel)
  • Montering: 35 mm DIN-skinne, EN 60715
  • Grad av beskyttelse: IP 20 (innebygd)
  • Materiale i huset: Termoplast: Slukningsgrad UL 94 V-0
  • Termisk beskyttelse: Ja
  • Driftstilstand / feilindikering: Grønn ok / Rød defekt

Ytterligere funksjoner

  • Fjernkontakter (RC): Valgfritt
  • RC Switching Capacity: AC: 250V / 0.5 A; DC: 250V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A
  • Tverrsnitt for RC-leder (maks.): 16 AWG (Solid) / 1,5 mm² (Solid)