VIOX VSP1-D20/1(S)+1 Pluggbar enpolet SPD
VIOX VSP1-D20/1(S)+1 Pluggable Single-Pole SPD offers comprehensive surge protection for sub-distribution boards. This Class II+III/Type 2+3 device safeguards L-N and N-PE modes with 10kA nominal and 20kA maximum discharge current. Featuring high-energy MOV and GDT elements, it operates from 60V to 400V AC with <25ns response time for L-N and <100ns for N-PE. IEC 61643-11:2011 and EN 61643-11:2012 compliant, it provides voltage protection levels from 0.2kV to 1.8kV. With IP20 protection, thermal safeguards, and optional remote contacts, this versatile SPD suits various electrical installations, combining reliability and performance for enhanced power system protection in diverse applications.
Send oss dine krav, så gir vi deg et tilbud innen 12 timer
- TEL:+8618066396588
- Whatsapp:+8618066396588
- Email:sales@viox.com
VIOX VSP1-D20/1(S)+1 Pluggbar enpolet SPD
Oversikt
The VIOX VSP1-D20/1(S)+1 is a high-performance Pluggable Single-Pole Surge Protective Device (SPD) designed for use in sub-distribution boards. This versatile device offers robust protection for L-N and N-PE modes, making it an ideal solution for various electrical installations.
Viktige funksjoner
- Class II, Class III, Type 2, Type 3 device
- Bruksområde: Underdistribusjonstavler
- Mode of Protection: L-N, N-PE
- Surge Ratings: In = 10 kA (8/20 μs)
- IEC/EN/UL Category: Class II+III / Type 2+3
- Protective Elements: High Energy MOV and GDT
- Hus: Pluggbar design
- Samsvar: IEC 61643-11:2011, EN 61643-11:2012
Tekniske spesifikasjoner
IEC Elektrisk | 75 | 150 | 275 | 320 | 385 | 440 |
---|---|---|---|---|---|---|
Nominell vekselstrømspenning (50/60 Hz) | 60 V | 120 V | 230 V | 230 V | 230 V | 400 V |
Maximum Continuous Operating Voltage (AC) (L-N) | 75 V | 150 V | 275V | 320 V | 385 V | 440 V |
Maximum Continuous Operating Voltage (AC) (N-PE) | 255V | |||||
Nominal Discharge Current (8/20 μs) (L-N) / (N-PE) | 10kV / 10kA | |||||
Maximum Discharge Current (8/20 μs) (L-N) / (N-PE) | 20 kA / 20 kA | |||||
Voltage Protection Level (L-N) / (N-PE) | 0.2kV/1.5kV | 0.6kV/1.5kV | 1.3kV/1.5kV | 1.5kV/1.5kV | 1.5kV/1.5kV | 1.8kV/1.5kV |
Follow Current Interrupt Rating (N-PE) | 100Arms | |||||
Response Time (L-N) / (N-PE) | < 25 ns / < 100 ns | |||||
Reservesikring (maks.) | 125 A gL / gG | |||||
Short-Circuit Current Rating (AC) (L-N) | 10 kA | |||||
TOV Withstand 5s (L-N) | 90V | 180V | 335V | 335V | 335V | 580V |
TOV 120min (L-N) | 115V | 230V | 440V | 440V | 440V | 765V |
modus | Tåler | Tåler | Sikker feil | Sikker feil | Sikker feil | Sikker feil |
TOV Withstand 200ms (N-PE) | 1200V |
Mekaniske og miljømessige spesifikasjoner
- Driftstemperaturområde: -40 °F til +158 °F [-40 °C til +70 °C].
- Tillatt luftfuktighet ved drift: 5%...95%
- Atmosfærisk trykk og høyde: 80k Pa ... 106k Pa / -500 m....2000 m
- Dreiemoment for terminalskruer: 39,9 lbf.in [4,5 Nm]
- Ledertverrsnitt (maks.): 2 AWG (massiv, fåtrådet) / 4 AWG (fleksibel)
- 35 mm² (massiv, flertrådet) / 25 mm² (fleksibel)
- Montering: 35 mm DIN-skinne, EN 60715
- Grad av beskyttelse: IP 20 (innebygd)
- Materiale i huset: Termoplast: Slukningsgrad UL 94 V-0
- Termisk beskyttelse: Ja
- Driftstilstand / feilindikering: Grønn ok / Rød defekt
Ytterligere funksjoner
- Fjernkontakter (RC): Valgfritt
- RC Switching Capacity: AC: 250V / 0.5 A; DC: 250V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A
- Tverrsnitt for RC-leder (maks.): 16 AWG (Solid) / 1,5 mm² (Solid)